DOI QR코드

DOI QR Code

Fire Resistance Performance of Recycling PET Fiber Reinforced High Strength Concrete Circular Column

재생 PET섬유 보강 고강도 콘크리트 원형기둥의 내화성능

  • Seo, Tae-Seok (Advanced Material R& D Team, Hyundai Engineering & Construction) ;
  • Gong, Min-Ho (Research & Development Center, Hyundai Engineering) ;
  • Kwon, Hae-Won (Research & Development Center, Hyundai Engineering)
  • Received : 2016.07.27
  • Accepted : 2016.10.11
  • Published : 2016.12.20

Abstract

This study evaluates the fire resistance performance for 60MPa high strength concrete reinforced by recycling polyethylene-terephthalate(PET) fiber(fiber content : 0.05 vol.%). Because there is no fire resistance test results for circular concrete column, a fire resistance test was carried out for circular concrete column specimens. As a result, it was confirmed that PET fiber was effective against the spalling control of high strength concrete. However, the specimen with cover thickness 30mm did not satisfy the temperature standard of main reinforcement, and the specimen with cover thickness 40mm satisfied the temperature standard of main reinforcement. Therefore, more than 40mm cover thickness was demanded for stable fire resistance performance.

본 연구에서는 PET섬유(혼입율: 0.05vol.%)로 보강된 60MPa 고강도 콘크리트의 내화특성을 검토하였다. 특히 원형 기둥에 대한 내화실험 결과가 아직까지 없기 때문에 콘크리트 원형기둥을 대상으로 내화시험을 실시하였다. 그 결과 PET섬유가 고강도 콘크리트 폭렬 제어에 효과가 있는 것을 확인할 수 있었다. 하지만 피복두께 30mm 시험체에서는 주철근 온도규정을 만족시키지 못하는 것으로 나타났고 피복두께 40mm 시험체에서는 주철근 온도규정을 만족하는 것으로 나타났다. 따라서 내화성능을 만족하기 위해서는 40mm 이상의 피복두께가 필요할 것으로 판단된다.

Keywords

References

  1. Kim GY, Lee TG, Kim YS, Nam JS, Lee SH. Technology of Fire Resistance Performance of High Strength Concrete Column. Magazine of the Korea Concrete Institute. 2012 Jan;24(1):51-5. https://doi.org/10.22636/MKCI.2012.24.1.51
  2. Yeo IH. Criteria for Fire Resistant Performance Evaluation of Reinforced Concrete Members. Magazine of the Korea Concrete Institute. 2014 Nov;26(6):43-6. https://doi.org/10.22636/MKCI.2014.26.6.43
  3. Ministry of Land & Transport and Maritime Affairs. Notification. No.2008-334 Fire Resistance Performance Management Standard for Column & Girder of the High Strength Concrete, Seoul, Korea. 2008 Jul.
  4. Nishida A, Ymazaki N, Inoue H, Schneider U, Diederichs U. Study on the Properties of High-Strength Concrete with Short Polypropylene Fiber for Spalling Resistance. Proceed -ings of International Conference on Concrete under Severe Conditions(CONSEC'95,). 1995 Feb;2(1):1141-50.
  5. Atkinson T. Polypropylene Fibers Control Explosive Spalling in High-Performance Concrete. Japan Concrete Institute. 2004;38(10):69-70.
  6. Song YC, Kim YR, Kim OJ, Lee DB. Evaluation on Fire Resistance Performance of High Strength Concrete Containing Fibre. Journal of the Korea Institute of Building Construction. 2010 Oct;10(5):129-36. https://doi.org/10.5345/JKIC.2010.10.5.129
  7. Purkiss J A. Steel Fiber Reinforced Concrete at Elevated Temperatures. International Journal of Cement Composites and Lightweight Concrete. 1984;6(3):179-84.. https://doi.org/10.1016/0262-5075(84)90006-X
  8. Lie T T, Kodur V K R. Thermal and Mechanical Properties of Steel Fiber Reinforced Concrete at Elevated Temperatures. Canadian Journal of Civil Engineering. 1996;23:511-17. https://doi.org/10.1139/l96-055
  9. Suhaendi S L, Takashi H. Effect of Short Fibers on Residual Permeability and Mechanical Properties of Hybrid Fibre Reinforced High Strength Concrete after Heat exposition. Cement and Concrete Research. 2006;36:1672-78. https://doi.org/10.1016/j.cemconres.2006.05.006
  10. Won JP, Park CG, Kim HH, Lee SW. Effect of Recycled PET Fiber Geometry and Length on the Plastic Shrinkage Cracking of Cement Based Composites. Journal of the Korea Concrete Institute. 2007 Apr;19(2):233-39. https://doi.org/10.4334/JKCI.2007.19.2.233
  11. Kim SB, Kim JH, Han BG, Hong GH, Song JG. An Experimental Study on the Creep Behavior and Crack Resistance of Hwangtoh Concrete Mixed with Recycled -PET Fiber. Journal of the Korea Concrete Institute. 2009 Jun;21(3):265-73. https://doi.org/10.4334/JKCI.2009.21.3.265
  12. Vachirapanyakun S, Lim MK, Choi DU. Seismic Performance of Circular RC Columns Retrofitted Using Ductile PET Fibers. Journal of the Korea Concrete Institute. 2016 Jun;28(3):289-98. https://doi.org/10.4334/JKCI.2016.28.3.289
  13. Stephen L. Rosen, Christopher S. Brazel, Fundamental Principles of Polymeric Materials. 3rd rev. ed. New York: Wiley; 2012. 107 p.
  14. Song YW, Yoon S, Jeong Y, Gong MH. Properties of Fire Resistance of High-Strength Concrete with Diameter and Fiber Content of PET Fiber. Conference of the Korea Concrete Institute. 2009 Spring;21(1):475-6.
  15. Ministry of Land & Transport and Maritime Affairs. Standard for Concrete Structure. Seoul, Korea, pp.86, 2012
  16. Youm KS, Jeon HK, Kim HY. Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns without Loading. Conference of the Korea Concrete Institute. 2009 Aug;21(4):465-71.