DOI QR코드

DOI QR Code

Comparison of Three Supraglottic Airway Devices in Neutral and Cervical Neck Collar Position

융복합적 기술이 적용된 성문위기구들의 삽관용이성 비교

  • Tak, Yang-Ju (Dept. of Paramedic Science, Korea National University of Transportation)
  • 탁양주 (한국교통대학교 응급구조학과)
  • Received : 2016.10.24
  • Accepted : 2016.12.20
  • Published : 2016.12.28

Abstract

Purpose of this study was to compare the easiness of insertion of three Supraglottic airway devices(SADs) in a neutral and cervical neck collar position in a manikin setting. Three different SADs-Laryngeal Mask Classic (LMA), I-gel and Streamlined Liner of the Pharynx Airway(SLIPA) were applied. Thirty nine emergency medical technicians (EMTs) who are working in Korea 119 rescue services were taught briefly about the use of the LMA, I-gel and SLIPA in a manikin setting. The time to effective ventilation was shorter in I-gel ($10.5{\pm}2.2$, $11.4{\pm}5.7$) and SLIPA ($12.3 {\pm}5.1$, $12.0{\pm}6.8$) than LMA ($17.2{\pm}3.2$, $18.5{\pm}5.5$) in a neutral and cervical neck collar position, respectively(p<0.05). There was no difference between head positions in each of the airways. In conclusion, in the speed of insertion, I-gel and SLIPA were superior to LMA in the neutral and cervical collar setting of a manikin.

본 연구는 환자의 경추보호대 착용 여부에 따른 후두마스크기도기(LMA)와 I-gel, Streamlined Liner of the Pharynx Airway(SLIPA) 등 3가지 성문위기구의 삽관 용이성을 비교하기 위해 시행되었다. 응급의료현장에서 활동 중인 119 구급대원 39명에게 3가지 성문위기구에 대한 짧은 교육을 시행한 후 삽관시간과 삽관시도횟수를 측정하였다. 삽관시간은 중립위와 경추보호대 착용 시 모두 I-gel($10.5{\pm}2.2$, $11.4{\pm}5.7$), SLIPA($12.3 {\pm}5.1$, $12.0{\pm}6.8$), LMA($17.2{\pm}3.2$, $18.5{\pm}5.5$) 순으로 빨랐다 (p<0.05). 각 기도기별 중립위와 경추보호대 착용 시 삽관시간의 차이는 없었다. 결론적으로 I-gel과 SLIPA가 LMA보다 중립위와 경추보호대 착용 시 모두에서 삽관시간이 더 빠른 결과를 보였다.

Keywords

References

  1. R. W. Neumar, C. W. Otto, M. S. Link, S. L. Kronick, M. Shuster, C. W, "Callaway el al. Part 8: Adult advanced cardiovascular life support: 2010 American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care" Circulation, Vol. 122, No. 3, pp. 729-767, 2010. https://doi.org/10.1161/CIRCULATIONAHA.109.931691
  2. Mark S. Link, Lauren C. Berkow, Peter J. Kudenchuk, Henry R. Halperin, Erik P. Hess, Vivek K. Moitra, Robert W. Neumar, Brian J. O'Neil, James H. Paxton, Scott M. Silvers, Roger D. White, Demetris Yannopoulos and Michael W. Donnino, "Part 7: Adult Advanced Cardiovascular Life Support 2015 American Heart Association Guidelines Update for Cardiopulmonary" Circulation, Vol. 132, No. 13, pp. 729-767, 2015.
  3. K. Hasegawa, A. Hiraide, Y. Chang, D. F. Brown. "Association of prehospital advanced airway management with neurologic outcome and survival in patients with out-of-hospital cardiac arrest" The Journal of the American Medical Association, Vol. 309, No. 3, pp257-266, 2013. https://doi.org/10.1001/jama.2012.187612
  4. J. McMullan, R. Gerecht, J. Bonomo, R. Robb, B. McNally, J. Donnelly, H. E. Wang, "CARES Surveillance Group. Airway management and outof-hospital cardiac arrest outcome in the CARES registry" Resuscitation, Vol. 85, No. 5, pp617-622, 2014. DOI: http://dx.doi.org/10.1016/j.resuscitation.2014.02.007
  5. The Korean Society of Emergency Medicine, "Emergency Medicine: Endotracheal intubation and Mechanical ventilation", pp323-35, Koonja Publishing Co., 2011.
  6. U. J. Choi, K. J. Cho, "A comparison of endotracheal intubation using the macintosh laryngoscope, the gum elastic bougie and pentax airway scope in neck-stabilized manikin" The Journal of Korean Society of Emergency Medical Technology, Vol. 15, No. 3, pp.71-80, 2011.
  7. J. Y. Hwang, K. J. Cho, "Comparison between laryngeal tube suction II and laryngeal mask airway in novice users-A manikin study" The Journal of Korean Society of Emergency Medical Technology, Vo6. 11, No. 3, pp.19-28, 2012.
  8. U. J. Choi, G. S. Shim, "Pre-hospitalization Advanced Airway Management Using the KING LTS-DTM and the LMA ProSealTM" Journal of the Korea Academia-Industrial cooperation Society, Vol. 13, No. 12, pp.5893-5900, 2012. https://doi.org/10.5762/KAIS.2012.13.12.5893
  9. S. T. Kim, B. R. Kang, Y. J. Tak, "Comparative assessment of the easiness and speed of insertion of three supraglottic airway devices: A manikin study" The Journal of Korean Society of Emergency Medical Technology, Vol. 16, No. 2, pp.25-34, 2012.
  10. R. K. Tam, J. Maloney, I. Gaboury, J. M. Verdon , J. Trickett, S. D. Leduc, "Review of endotracheal intubations by Ottawa advanced care paramedics in Canada" Prehospital Emergency Care, Vol. 13, No.3, pp.311-6, 2009. https://doi.org/10.1080/10903120902935231
  11. B. J. Jeong, S. S. Choi. S. W. Yun, "The Relationship between Advanced Airway Management and Self-Efficacy by Level 1 Emergency Medical Technicians(EMT) in 119 Emergency Medical Service" Journal of the Korea Academia-Industrial cooperation Society, Vol. 14, No. 4, pp.1709-1717, 2013. DOI: http://dx.doi.org/10.5762/KAIS.2013.14.4.1709
  12. G. S. Shim, E M. Kim, "Advanced airway management for the prehospital traumatic patient" Journal of the Korea Academia-Industrial cooperation Society, Vol. 14, No. 5, pp.2360-2367, 2013. DOI: http://dx.doi.org/10.5762/KAIS.2013.14.5.2360
  13. R. M. Levitan, W. C. Kinkle. "Initial anatomic investigations of the I-gel airway: a novel supraglottic airway without inflatable cuff" Anaesthesia, Vol. 60, pp.1022-1026, 2005. https://doi.org/10.1111/j.1365-2044.2005.04258.x
  14. J. M. Koh, J. H.. Kim, J. M. Jo, "Improvement device on scope of practice of paramedic in the emergency medical service's act" Korean Journal of Emergency Medical Service, Vol. 11, No. 3, pp.17-30, 2007.
  15. Y. L. Kim, H. Y. Lee, G. W. Kim, H. S. Jo, J. H. Jung, "Comparative study of prehospital airway devices tested using a manikin model: a comparison of the laryngeal airway classic (LMA Classic $^{TM}$), Cobra perilaryngeal airway(Cobra PLA$^{TM}$) and the King laryngeal tube(King LT$^{TM}$)" Korean Journal of Emergency Medical Service, Vol. 21, No. 6, pp.776-782, 2010.
  16. Y. M. Choi, S. M. Cha, H. Kang, C. W. Baek, Y. H. Jung, Y. C. Woo, "The clinical effectiveness of the streamlined liner of pharyngeal airway(SLIPATM) compared with the laryngeal mask airway ProSealTM during general anesthesia" Korean Joural of Anesthesiology, Vol. 58, pp. 450-457, 2010. https://doi.org/10.4097/kjae.2010.58.5.450
  17. K. Stroumpoulis, C. Isaia, E. Bassiakou, I. Pantazopoulus, G. Troupis, A. Mazarakis, "A comparison of the i-gel and classic LMA insertion in manikins by experienced and novice physicians" European Journal of Emergency Medicine, Vol. 19, No.1, pp.24-7, 2012. https://doi.org/10.1097/MEJ.0b013e3283474ab3
  18. H. H. Park, K. O. Lee, S. O. Kim, "A study on the participation motivation of clinical nurses in job training."Journal of Digital Convergence, Vol. 14, No. 8, pp. 319-329, 2016. https://doi.org/10.14400/JDC.2016.14.8.319