DOI QR코드

DOI QR Code

A Study of Bolt Tightening Changing Factor according to Durability Degradation

내구 열화에 따른 샤시계 볼트 체결력 변화 인자 연구

  • 최동영 (가속내구개발팀 (현대자동차)) ;
  • 최재칠 (가속내구개발팀 (현대자동차)) ;
  • 한종욱 (가속내구개발팀 (현대자동차))
  • Received : 2014.11.06
  • Accepted : 2014.12.22
  • Published : 2015.03.31

Abstract

In vehicle development process, durability test should be carried out in field condition. Nowadays there are many customer live there multiple conditions. It makes change of the car's material. Such change causes to lose a bolt. Diversifications of climatic conditions are also a matter of loosening the bolt. To avoid this problem, to identify the cause of the problem, and the solution should be applied. To avoid problems during the durability development test should be measured by the clamping force. Ultrasonic instruments clamping force without affecting the torque can be measured. This instrument is part of the problem by monitoring the clamping force required to obtain objective data.

Keywords

Cited by

  1. 증발가스 재액화 드럼의 단열구조에 관한 실험적 연구 vol.25, pp.1, 2015, https://doi.org/10.7842/kigas.2021.25.1.7