DOI QR코드

DOI QR Code

Low Power NDIR CO2 Sensor Using LED Light Source with a Smart Device Interface

스마트 기기와 결합 가능한 LED 광원을 사용하는 저전력용 비분산 적외선 CO2센서

  • Kim, Jong-heon (Kwangwoon University Department of Electronics Convergence Engineering) ;
  • Lee, Chan-joo (Shinhan University Department of IT Convergence)
  • Received : 2015.06.08
  • Accepted : 2015.08.06
  • Published : 2015.08.31

Abstract

In this paper, a portable high efficiency nondispersive infrared(NDIR) $CO_2$ sensor module with a smart device interface is developed. For low power consumption design, an IR LED was used instead of tungsten lamp for light source and an optical waveguide optimized to the sensor module is designed. With the smart device interface, power of the sensor module is applied from the battery of smart phone. The measured data of the sensor module such as $CO_2$ concentration, temperature, and humidity are displayed on the smart phone using android application. From measured results, the developed sensor module shows ${\pm}60ppm$ tolerance error from 0 to 3,000ppm $CO_2$ concentration range among $-10^{\circ}C$ and $50^{\circ}C$ ranges.

본 논문에서는 스마트폰에 장착 가능하고 휴대가 가능한 고효율 NDIR $CO_2$ 센서 모듈을 개발하였다. 저전력 회로 설계를 위하여 텅스텐램프 대신에 적외선 LED를 사용하였으며, 센서 모듈에 최적화된 광도파로를 설계 및 제작하였다. 스마트폰과 인터페이스가 가능한 회로를 통하여 스마트폰의 전원으로 센서 모듈이 구동되도록 설계하였다. $CO_2$ 농도, 온도 및 습도 등 측정된 센서의 데이터는 스마트폰 앱을 통하여 화면에 표시하였다. 측정 결과, 개발된 센서 모듈은 온도$-10^{\circ}C{\sim}50^{\circ}C$ 구간에서 0 ~ 3,000ppm 범위의 $CO_2$ 농도를 측정할 수 있었으며 측정 오차는 ${\pm}60ppm$이내였다.

Keywords

References

  1. G.-S. Kim, J.-T. Oh, H. S. Kim, and J.-C. Kim, "A study on $CO_2$ sensor module using NDIR method," J. IEEK, vol. 46SC, no. 2, pp. 36-40, Mar. 2009.
  2. S. H. Yi, Y. H. Park, S. O. Han, N. K. Min, E. S. Kim, and T. H. Ahn, "Novel NDIR $CO_2$ sensor for indoor air quality monitoring," Technical Digest of The 13th Int. Conf. Solid-State Sensors, Actuators Microsystems, pp. 1211-1214, Seoul, Korea, Jun. 2005.
  3. D. Garcia-Romeo, H. Fuentes, N. Medrano, B. Calvo, P. A. Martinez, and C. Azcona, "A NDIR-based $CO_2$ monitor system for wireless sensor networks," 2012 IEEE 3rd Latin Am. Symp. Cir. Syst. (LASCAS), pp. 1-4, Feb.-Mar. 2012.
  4. D. Gibson and C. MacGregor, "A novel solid state non-dispersive infrared $CO_2$ gas sensor compatible with wireless and portable deployment," J. Sensors, vol. 13, no. 6, pp. 7079-7103, 2013. https://doi.org/10.3390/s130607079
  5. J.-W. Kwon, J.-C. Kim, G.-S. Kim, and H. Kim, "Air quality monitoring system using NDIR-$CO_2$ sensor for underground space based on wireless sensor network," J. IEEK, vol. 46, no. 4, pp. 28-38, Jul. 2009.
  6. Y. Wang, M. Nakayama, M. Yagi, M. Nishikawa, M. Fukunaga, and K. Watanabe, "The NDIR $CO_2$ monitor with smart interface for global networking," IEEE Trans. Instrumentation and Measurement, vol. 54, no. 4, pp. 1634-1639, Aug. 2005. https://doi.org/10.1109/TIM.2005.851474
  7. http://lmsnt.com/datasheets/Standard%20chip/Lms43LED/lms43led_series_rev040512.pdf http://lmsnt.com/datasheets/PD/Lms43PD/-03/Lms4 3PD-03series_rev070515.pdf Retrieved July, 20, 2015, from http://lmsnt.com/
  8. "AN131-CO2 Sensor Calibration: What You Need to Know" Retrieved July, 20, 2015, from http://www.co2meters.com/Documentation/AppNotes/AN131-Calibration.pdf
  9. H. P. Beerman, "The pyroelectric detector of infrared radiation," IEEE Trans. Electron Devices, vol. 16, no. 16, pp. 554-557, Jun. 1969. https://doi.org/10.1109/T-ED.1969.16798

Cited by