경제성 평가를 이용한 프리쿨링시스템의 국내 적용성 연구

A Study on Application of the Free Cooling System with Dry Cooler Using Economic Evaluation

  • 윤정인 (부경대학교 냉동공조공학과) ;
  • 손창효 (부경대학교 냉동공조공학과) ;
  • 김희민 (부경대학교 대학원 냉동공조공학과) ;
  • 김영민 ((주)정인하이테크)
  • Yoon, Jung-In (Refrigeration and Air-conditioning Engineering, Pukyong University) ;
  • Son, Chang-Hyo (Refrigeration and Air-conditioning Engineering, Pukyong University) ;
  • Kim, Hee-Min (Graduate School of Refrigeration and Air-conditioning Engineering, Pukyong University) ;
  • Kim, Young-Min (JUNG IN HI-TECH CO..LTD.)
  • 투고 : 2015.05.18
  • 심사 : 2015.06.01
  • 발행 : 2015.08.31

초록

Recently, because of the deterioration of the nuclear generating station and increase of the cooler and heater, energy problem is increasing. To save the energy, the free cooling system is developed. The free cooling system is that cool the water to use cooled air in winter and is used in industrial process or data center. Yoon check the energy of free cooling system with dry cooler in korea. In this study, the value of the free cooling system with dry cooler is confirmed through using the NPV that is economic evaluation. when temperature degree of the cooled water is 10, in Chuncheon and Seoul the value is the most high. When temperature degree of the cooled water is 20, in Ulsan the value is the most high. As the result, because the using the temperature degree of the cooled water is high in the industrial process, the free cooling system is advantageous in korea.

키워드

참고문헌

  1. S. H. Park and J. H. Seo, 2014, "Economic Evaluation of Air-side Economizer System for Data Center", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 26, No. 4, pp. 145-150. https://doi.org/10.6110/KJACR.2014.26.4.145
  2. J. I. Yoon, C. H. Son, J. H. Heo and Y. M . Kim, 2014, "Analysis on the Energy Saving Effect of Free Cooling System in Data Center", Journal of the Korean Society for Power System Engineering, Vol. 18, No. 3, pp. 73-78. https://doi.org/10.9726/kspse.2014.18.3.073
  3. J. I. Yoon, S. M. Baek, J. H. Heo, Y. M . Kim and C. H. Son 2014, "A study on design for free cooling system using dry cooler", Journal of the Korean Society of Marine Engineering, Vol. 38, No. 9, pp. 1027-1031. https://doi.org/10.5916/jkosme.2014.38.9.1027
  4. Y. Nikolaidis and P. A. Pilavachi, 2009, "Economic evaluation of energy saving measures in a common type of Greek building", Applied Eenrgy, Vol. 86, No. 12, pp. 2550-2559. https://doi.org/10.1016/j.apenergy.2009.04.029
  5. G. N. Donald, G. E. Ted and P. L. Jerome, 2004, "Study Guide for Engineering Economic Analysis", Oxford University Press, pp. 71-95.