DOI QR코드

DOI QR Code

Structural Performance of Steel Fiber Reinforced Concrete Continuous Slab without Reinforcement

강섬유보강 콘크리트를 사용한 무배근 연속슬래브의 구조성능

  • Received : 2015.04.27
  • Accepted : 2015.08.12
  • Published : 2015.08.30

Abstract

Slab is one of the most important members in the building structures because it covers the largest area of the building. But, amount of reinforcement in this member is relatively small because of its small supporting loads. And large exposed area in slab can induce the cracks. To improve this characteristics, the new slab system consist of structural deck-plate and fiber reinforced concrete was suggested for improving construction ability and reduction of construction period. Basic concept of this slab system is that structural deck-plate can replace the tensile reinforcing bars and concrete form, and fiber reinforced concrete can replace the temperature reinforcement. But, previous study was limited because it tested only simply supported slab specimens. This study tested various continuous slab specimens to find the applicability of the suggested new slab system without any additional reinforcement. Design concept is that structural design of slab is assumed as simply support slab, but it should keep the negative moment cracks under allowable crack width in service load conditions. Four continuous slab specimens in total were tested for analyzing the flexural strength, stiffness, deflection, crack development and failure pattern. Test results indicated that suggested new slab system appeared to be better flexural capacity and stiffness than normal reinforced concrete slab with negative moment reinforcement. And it can control the cracks under the allowable crack width upto the service and factored loads.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. Architectural Institute of Korea. (2007). Report on the design method for steel fiber reinforced concrete SOG system, AIK research report, 25-62
  2. Bridgestone. (1992). Catalog for composite slab system using Dramix steel fiber
  3. Choi, H., Choi, K., Choi, O. & Hwang, Y. (2012). A Prediction Model of Shrinkage Cracking of Steel Fiber Reinforced Concrete. Journal of AIK, 28(6), 59-66
  4. Choi, K., Park, H. & Wight, J. (2007). Shear Strength of Steel Fiber Reinforced Concrete Beams without Web Reinforcement. ACI Structural Journal, 104(1), 12-21
  5. Hong, G. (2014). Structural Performance of Steel Fiber Reinforced Concrete Slab with the Steel Deck-Plate. Journal of AIK, 30(7), 13-20
  6. Hwang, H., Hong, G., Park, H., Kim, Y. & KIm, J. (2010). Effects of Shore Stiffness and Concrete Cracking on Slab Construction Load II: Measurements and Comparisons, Journal of KCI, 22(1), 51-58
  7. Korea Concrete Institute. (2012). Code requirement for reinforced concrete structure. Gimoon-Dang Press
  8. Korea Concrete Institute. (2014). Development of Slab and SOG using Amorphous steel fiber", KCI research report, 11-90
  9. Oh, T., Kim, D. & Kim, D. (2012). Research on flexural performance test of slab by varying the support conditions. Proceeding of AIK conference, 32(2), 429-430
  10. Shim, H., Yang, K., Lee, E. & Chung, H. (2004). The Experimental Study of Flexural Bahavior of Continuous Composite Slab Reinforced with Structural Steel Deck Plate. Proceeding of AIK conference, 24(2), 111-114
  11. Yang, K., Ko, Y. & Chung, H. (2005). Cracking Behavior in the Negative Moment Region of Continuous Composite Slabs Reinforced with Structural Steel Decking. Journal of AIK, 21(1), 21-30