Abstract
This study is to compare the differences of bonding strength based on the Degassing temperatures and various opaque materials for Ni-Cr alloy specimen which does not contain beryllium(Be). Numerous comparison tests have been performed to measure the bonding strength by experimenting 3-point flexural rigidity tests in order to find out ways of stabilization and enhancement of bonding strength between metal and porcelain. AVOVA, surface component observation experiment by SAM/EDS, and Tukey's HSAD posteriori tests results are as follows: First, The bonding strength in all groups has exceeded the minimum (25MPa) of ISO9693 bonding strength regulation for dental mental-porcelain specimen. Second, The bonding strength of Group V1 was $32.37{\pm}1.91MPa$, $38.25{\pm}1.38MPa$ in Group V2, $46.43{\pm}2.14MPa$ in Group V3 and $47.21{\pm}1.72MPa$ Group V4. The difference has been statistically meaningful. Tukey's HSAD posteriori tests results have shown that the bonding strength in Group V4 was higher than that of Group V1. Third, the bonding strength between metal and porcelain without degassing process was higher than that of with degassing process, and the bonding strength of powder opaque was higher than that of paste opaque. Fourth, Group V4 has ranked the highest on the comparison table of metal and porcelain bonding strength.
본 연구는 베릴륨 함유하지 않은 Ni-Cr계 도재용 금속에 전용도재를 도포, 소성된 시편을 3점 굴곡 시험으로 결합강도를 측정하고, SAM/EDS로 표면성분관찰 실험한 AVOVA와 Tukey HSAD 사후검정을 실시한 결과는 다음과 같은 결론을 얻었다. 첫째. 모든 군에서 ISO 9693의 치과용 금속-도재 시편의 최소 결합강도의 최소치인 25 MPa의 전단결합강도를 상위하며 안정적인 결과값을 나타냈다. 둘째. 결합 강도는 대조군 V1은 $32.37{\pm}1.91MPa$으로 나타났고, 실험군 V2 $38.25{\pm}1.38MPa$, 실험군 V3 $46.43{\pm}2.14MPa$, 그리고 실험군 V4 $47.21{\pm}1.72MPa$, 순으로 나타났으며 통계적으로 유의한 차이를 보였다. 사후 검정 (Tukey's HSD test) 결과, 결합강도 실험결과 실험군 V4는, 대조군 V1보다 높게 나타났다. 셋째. 금속-도재의 결합에서 산화처리를 시행한 군보다 시행하지 않고 불투명 도재를 도포하고 소성한 군이 높게 나타났으며, paste불투명 도재보다 분말 불투명도재의 사용에 따른 결합강도가 더 높게 나타났다. 넷째. 실험군 V4는 금속과 도재의 결합강도 비교에서 가장 높게 나타났다.