Abstract

The method measuring LEP (liquid entry pressure) was optimized to evaluate the wettabilities of hydrophobic membranes which might affect long-term durability of membrane in MD (membrane distillation) process. Conductivity of the permeate was monitored to measure the LEPs of PE (polyethylene) and PVDF (polyvinylidene di-fluoride) hollow fiber membranes from highly concentrated synthetic feed water of 20 wt% NaCl. Holding time over 5 min and the ratio of membrane area to the tank volume more than $10m^2/m^3$ were required to ensure LEP value.

막증류(membrane distillation, MD)용 분리막의 장기 내구성능에 영향을 미치는 인자인 소수성 분리막의 젖음 현상에 대한 평가 지표로 사용되는 액체투과압력(liquid entry pressure, LEP) 측정 방법을 최적화하였다. PE (polyethylene) 분리막 및 PVDF (polyvinylidene di-fluoride) 중공사 분리막의 LEP를 측정하기 위하여 20 wt%의 고농도 염수를 제조하여 원수로 사용하고 투과수의 전도도를 모니터링하였다. PE와 PVDF 중공사 분리막의 신뢰성 있는 LEP 측정을 위해서는 5 min 이상의 holing time을 두고 주입 압력을 증가시켜야 하며, 증류수 수조의 물량대비 분리막의 면적비 또한 $10m^2/m^3$ 이상으로 부여되어야 함을 확인하였다.

Keywords

References

  1. M. Khayet, P. Godino, and J. I. Mengual, "Nature of flow on sweeping gas membrane distillation", J. Membr. Sci., 170, 243 (2000). https://doi.org/10.1016/S0376-7388(99)00369-5
  2. H. W. Cho and W. C. Shin, "The prospect of membrane distillation", Membr. J., 7, 57 (1997).
  3. S. H. Eum, A. S. Kim, and Y. T. Lee, "Permeate flux analysis of direct contact membrane distillation (DCMD) and sweep gas membrane distillation (SGMD)", Membr. J., 21, 236 (2011).
  4. K. Y. Chung, "Membrane distillation of the aqueous glucose solution", Membr. J., 10, 230 (2000).
  5. L. Song, B. Li, K. K. Sirkar, and J. L. Gilron, "Direct contact membrane distillation-based desalination: novel membranes, devices, larger-scale studies, and a model", Ind. Eng. Chem. Res., 46, 2307 (2007). https://doi.org/10.1021/ie0609968
  6. M. S. El-Bourawi, Z. Ding, R. Ma, and M. Khayet, "A framework for better understanding membrane distillation separation process", J. Membr. Sci., 285, 4 (2006). https://doi.org/10.1016/j.memsci.2006.08.002
  7. A. C. M. Franken, J. A. M. Nolten, M. H. V. Mulder, D. Bargeman, and C. A. Smolders, "Wetting criteria for the applicability of membrane distillation", J. Membr. Sci., 33, 315 (1987). https://doi.org/10.1016/S0376-7388(00)80288-4
  8. J. H. Min, M. S. Park, and J. H. Kim, "Preparation of hydrophobic porous PVDF membrane and application for membrane distillation", Membr. J., 24, 240 (2014). https://doi.org/10.14579/MEMBRANE_JOURNAL.2014.24.3.240
  9. D. H. Yu, M. A. Jeoung, J. W. Rhim, H. S. Byun, C. H. Jeong, Y. M. Lee, M. W. Seo, and S. Y. Nam, "Preparation and characterization of microporous PVDF membrane for Li-ion rechargeable battery", Membr. J., 17, 235 (2007).