Abstract

The tap water is generally known to be corrosive in the pH range at 6.5 ~ 7.5. And the degree of corrosion varies depending on the types of raw water such as river surface water or lake water of the dam. Although several corrosion index represents the corrosivity of tap water, the typical corrosion indexes such as Langelier saturation index (LI) and calcium carbonate precipitation potential (CCPP) were calculated to monitoring the corrosive water quality about raw and tap water in water distribution system. To control the corrosive water quality, the correlation between corrosion index and water quality factors were examined. In this study, corrosion index (LI, CCPP) and the pH was found to be most highly correlated.

Keywords

References

  1. AWWA, 1986, Corrosion Control for Operators.
  2. AWWA, 2000, Standard Methods for the Examination of Water and Wastewater, 20th. 2-30, APHA, Washington, D.C.
  3. Cheong, W., Kim, J., Park, D., Kim, S., Jeong, S., 2011, A study on the corrosion control of tap water by lime and carbon dioxide, J. KSWW, 25(2), 193-199.
  4. Hedberg, T., Vik, E. A., Ferguson, J. F., 1995, Internal corrosion in water distribution system, in proceedings from an international workshop and seminar at Chalmers University of Technology, Goteborg, Sweden, 59-66.
  5. Holm, T. R., Schock, M. R., 1998, Computing SI and CCPP using spreadsheet programs, J. AWWA, 90(7), 80-89. https://doi.org/10.1002/j.1551-8833.1998.tb08471.x
  6. Hwang, B. G., 2007, Evaluation of calcium carbonate saturation indices in water, J. KAIS, 8(1), 130-135.
  7. Hwang, B. G., Woo, D. S., 2009, Development of corrosion evaluation index calculation program of raw water and evaluation on corrosivity of tap water using the calcium carbonate saturation index, J. KAIS, 10(1), 177-185.
  8. Kawamura, S., 2000, Integrated Design and Operation of Water Treatment Facilities, John Wiley & Sons, Inc., New York.
  9. Kim, D. H., Cha, J. H., Hong, S. H., Kim, D. Y., Kim, C. W., 2009, Control of corrosive water in advanced water treatment plant by manipulating calcium carbonate precipitation potential, Korean J. Chem. Eng., 26(1), 90-101. https://doi.org/10.1007/s11814-009-0015-z
  10. Kim, D. H., Kim, D. Y., Hong, S. H., Kim, J. W., Kim, C. W., 2008, Development and implementation of a corrosion control algorithm based on calcium carbonate precipitation potential (CCPP) in a drinking water distribution system, J. Water Suppl. Res. Technol.-Aqua, 57(7), 531-539. https://doi.org/10.2166/aqua.2008.047
  11. Kim, J., Kim, Y. K., 2011, Characteristics and improvement of tap water corrosivity in Korea, J. KSWW, 25(5), 731-739.
  12. Kim, J., Lee, J., 2014, Improvement of tap water corrosivity by lime and carbon dioxide, J. KSWW, 28(6), 725-733.
  13. Kim, D. H., Lee, J. I., Lee, J. H., Han D. Y., Kim, D. Y., Hong, S. H., 2005, Corrosion characteristics by CCPP control in simulated distribution system, J. KSEE, 27(12), 1249-1256.
  14. Kwak, P. J., Kim, S. I., Woo, D. S., Nam, S. H., 1999, Effects of water aggressivity on the corrosion in water distribution systems, J. KSWW, 13(1), 134-139.
  15. Mays, L. W., 2000, Water Distribution Handbook, McGraw-Hill, New York.
  16. Ministry of Environment (MOE), 2014, http://www.me.go.kr.
  17. Park, Y. B., Kong, S. H., 2005, Control of the Ca$CO_3$ saturation index parameters for protecting the corrosion of waterworks pipe, J. Korean Ind. Eng. Chem., 16(3), 372-378.
  18. Rossum, J. R., Merrill, D. T., 1983, An evaluation of the calcium carbonate saturation indexes, J. AWWA, 75(2), 95-100. https://doi.org/10.1002/j.1551-8833.1983.tb05075.x
  19. Ryzner, J. W., 1960, A new index for determing amount of calcium carbonate scale formed by a water, J. AWWA, 52(10), 1263-1270. https://doi.org/10.1002/j.1551-8833.1960.tb00607.x
  20. Sarin, P., Snoeyink, V. L., Bebee, J., Kriven, W. M., Clement, J. A., 2001, Physico-chemical characteristics of corrosion scales in old iron pipes, Water Res., 35(12), 2961-2969. https://doi.org/10.1016/S0043-1354(00)00591-1
  21. Schock, M. R., 1999, Internal corrosion and deposition control, In Water Quality and Control, 5th Ed, AWWA.
  22. Tokyo Water Works, 2014, https;//www.waterworks.metro.tokyo.jp.
  23. US EPA, 2014, http://water.epa.gov/drink/contaminants.