References
- 2004, Marsden, A.L., Bazilevs, Y., Long, C.C. and Behr, M., "Recent Advances in Computational Methodology for Simulation of Mechanical Circulatory Assist Devices," WIREs Syst Biol Med 2014, Vol.6, No.2, pp.169-188.
- 2004, Goubergrits, L. and Affeld, K., "Numerical Estimation of Blood Damage in Artificial Organs," Artificial Organs, Vol.28, No.5, pp.499-507. https://doi.org/10.1111/j.1525-1594.2004.07265.x
- 2005, Day, S.W. and McDaniel, J.C., "PIV Measurements of Flow in a Centrifugal Blood Pump: Steady Flow," Journal of Biomechanical Engineering, Vol.127, No.2, pp.244-253. https://doi.org/10.1115/1.1865189
- 2004, Arora, D., Behr, M. and Pasquali, M., "A Tensor-based Measure for Estimating Blood Damage," Artificial Organs, Vol.28, No.11, pp.1002-1015. https://doi.org/10.1111/j.1525-1594.2004.00072.x
- 2006, Farinas, M.I., Garon, A., Lacasse, D. and N'dri, D., "Asymptotically Consistent Numerical Approximation of Hemolysis," Journal of Biomechanical Engineering, Vol.128, No.5, pp.688-696. https://doi.org/10.1115/1.2241663
- 2005, Arvand, A., Hormes, M. and Reul, H., "A Validated Computational Fluid Dynamics Model to Estimate Hemolysis in a Rotary Blood Pump," Artificial Organs, Vol.29, No.7, pp.531-540. https://doi.org/10.1111/j.1525-1594.2005.29089.x
- 2012, Fraser, K.H., Zhang, T., Taskin, M.E., Griffith, B.P. and Wu, Z.J., "A Quantitative Comparison of Mechanical Blood Damage Parameters in Rotary Ventricular Assist Devices: Shear Stress, Exposure Time and Hemolysis Index," Journal of Biomechanical Engineering, Vol.134, No.8, 081002. https://doi.org/10.1115/1.4007092
- 2004, Garon, A. and Farinas, M.I., "Fast Three-dimensional Numerical Hemolysis Approximation," Artificial Organs, Vol.28, No.11, pp.1016-1025. https://doi.org/10.1111/j.1525-1594.2004.00026.x
- 2012, Taksin, M.E., Fraser, K.H., Zhang, T., Wu, C., Griffith, B.P. and Wu, Z.J., "Evaluation of Eulerian and Lagrangian Models for Hemolysis Estimation," ASAIO Journal, Vol.58, No.4, pp.363-372. https://doi.org/10.1097/MAT.0b013e318254833b
- 1996, Naito, K., Suenaga, E., Cao, Z.L., Suda, H., Ueno. T., Natsuaki, M. and Itoh, T., "Comparative Hemolysis Study of Clinically Available Centrifugal Pumps," Artificial Organs, Vol.20, No.6, pp.560-563. https://doi.org/10.1111/j.1525-1594.1996.tb04480.x
- 2004, Johnston, B.M., Johnston, P.R., Corney, S. and Kilpatrick, D., "Non-Newtonian blood flow in human right coronary arteries:steady state simulations," Journal of Biomechanics, 37, pp.709-720. https://doi.org/10.1016/j.jbiomech.2003.09.016
- 1991, Cho, Y.I. and Kensey, K.R., "Effects of the nonb-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: steady flows," Biorheology, 28, pp.241-262.
- 1997, ASTM Committee, Standard Practice for Assessment of Hemolysis in Continuous Flow Blood Pumps, Annual Book of ASTM Standards, F1841-97, Vol.13.01.
- 1986, Wurzinger, L.J., Opitz, R., Eckstein, H., "Mechanical Bloodtrauma. An overview," Angeiologie, Vol.38, No.3, pp.81-97.
- 1990, Giersiepen, M., Wurzinger, L.J., Opitz, R., Reul, H., "Estimation of Shear Stress-related Blood Damage in Heart Valve Prosteses-In Vitro Comparison of 25 Aortic Valves," Artificial Organs, Vol.13, No.5, pp.300-306.
- 1994, Bludszuweit, C., "A Theoretical Approach to the Prediction of Haemolysis in Centrifugal Blood Pumps," Ph.D. thesis, University of Strathclyde Glasgow, Scotland.
- 1995, Jones, S.A., "A Relationship Between Reynolds Stresses and Viscous Dissipation: Implications to Red Cell Damage," Annals of Biomedical Engineering, Vol. 23, pp.21-28. https://doi.org/10.1007/BF02368297
- 2007, Ge, L., Dasi, L.P., Sotiropoulos, F. and Yoganathan, A.P., "Characterization of Hemodynamic Forces Induced by Mechanical Heart Valves: Reynolds vs. Viscous Stresses," Annals of Biomedical Engineering, Vol. 36, No.2, pp.276-297. https://doi.org/10.1007/s10439-007-9411-x
- 2002, De Wachter, D. and Verdonck, P., "Numerical Calculation of Hemolysis Levels in Peripheral Hemodialysis Cannulas," Artificial Organs, Vol.26, No.7, pp.576-582. https://doi.org/10.1046/j.1525-1594.2002.07079.x
- 1997, De Wachter, D.S., Verdonck, P.R., De Vos, J.Y. and Hombrouckx, R.O., "Blood Trauma in Plastic Haemodialysis Cannulae," Artificial Organs, Vol.20, No.7, pp.366-270.
Cited by
- EVALUATION OF LAGRANGIAN AND EULERIAN APPROACHES FOR PREDICTION OF HEMOLYSIS IN BLOOD PUMPS vol.20, pp.3, 2015, https://doi.org/10.6112/kscfe.2015.20.3.79
- DESIGN OF A CENTRIFUGAL BLOOD PUMP FOR ECMO DEVICE THROUGH NUMERICAL ANALYSES vol.21, pp.1, 2016, https://doi.org/10.6112/kscfe.2016.21.1.103