DOI QR코드

DOI QR Code

완전 무치악 환자에서 디지털 시스템을 이용한 임플란트 즉시 보철수복 증례

Immediate restorations in a fully edentulous patient utilizing digital system: A case report

  • 방정환 (연세대학교 원주의대 치과보철과) ;
  • 정승미 (연세대학교 원주의대 치과보철과) ;
  • 강세하 (연세대학교 원주의대 치과보철과) ;
  • 황찬현 (연세대학교 원주의대 치과보철과) ;
  • 김대환 (연세대학교 원주의대 치과보철과) ;
  • 최병호 (연세대학교 원주의대 구강악안면외과)
  • Fang, Jeong-Whan (Department of Prosthodontics, Wonju College of Medicine, Yonsei University) ;
  • Jeong, Seung-Mi (Department of Prosthodontics, Wonju College of Medicine, Yonsei University) ;
  • Kang, Se-Ha (Department of Prosthodontics, Wonju College of Medicine, Yonsei University) ;
  • Hwang, Chan-Hyeon (Department of Prosthodontics, Wonju College of Medicine, Yonsei University) ;
  • Kim, Dae-Hwan (Department of Prosthodontics, Wonju College of Medicine, Yonsei University) ;
  • Choi, Byung-Ho (Department of Oral and Maxillofacial Surgery, Wonju College of Medicine, Yonsei University)
  • 투고 : 2015.02.23
  • 심사 : 2015.04.03
  • 발행 : 2015.04.30

초록

본 증례는 하악 완전 무치악 환자에서 인상채득과 석고모형 제작과정 없이 CBCT와 구강스캐너를 이용하여 수술 전에 한 번의 치과방문으로 임플란트 식립과 동시에 즉시 보철수복을 시행하는 방법을 제시하였다. 무치악 부위 연조직 형태, 수직교합고경, 상하악 악궁관계에 대한 정보는 환자가 사용하고 있는 의치를 스캔하여 얻었다. 이 방법은 무치악 환자에서 임플란트를 이용한 보철수복 과정을 기존의 방법보다 내원 횟수를 단축시켰다.

This article describes how to use CBCT and an intraoral scanner in a fully edentulous case that enables the clinician to place implants with flapless guided surgery and to engage prefabricated, customized implant abutments at the time of implant surgery, with only 1 clinical consultation before implant surgery. The patient's existing denture is used to simulate the teeth, the soft tissue and the vertical dimension of occlusion, and jaw relationship in the fully edentulous jaw. It provides clinicians with a fast workflow and improves clinical efficiency.

키워드

참고문헌

  1. Derhalli M. The digitalizing of implant dentistry: a clinical evaluation of 15 patients. Compend Contin Educ Dent 2013;34:192-6.
  2. Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol 2005;76:503-7. https://doi.org/10.1902/jop.2005.76.4.503
  3. Ruppin J, Popovic A, Strauss M, Spuntrup E, Steiner A, Stoll C. Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical tracking vs. stereolithographic splint systems. Clin Oral Implants Res 2008;19:709-16.
  4. Van Assche N, van Steenberghe D, Guerrero ME, Hirsch E, Schutyser F, Quirynen M, Jacobs R. Accuracy of implant placement based on pre-surgical planning of three-dimensional conebeam images: a pilot study. J Clin Periodontol 2007;34:816-21. https://doi.org/10.1111/j.1600-051X.2007.01110.x
  5. van Steenberghe D, Naert I, Andersson M, Brajnovic I, Van Cleynenbreugel J, Suetens P. A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. Int J Oral Maxillofac Implants 2002;17:663-70.
  6. Hermann S, Carsten T, Stephan I, Gunter B, Robert S, Hans-Florian Z. Rapid Prototyping models for surgical planning with hard and soft tissue representation. Int Congress Series 2004;1268:567-72. https://doi.org/10.1016/j.ics.2004.03.139
  7. Ganz SD. Use of stereolithographic models as diagnostic and restorative aids for predictable immediate loading of implants. Pract Proced Aesthet Dent 2003;15:763-71.
  8. Hajeer MY, Millett DT, Ayoub AF, Siebert JP. Applications of 3D imaging in orthodontics: part II. J Orthod 2004;31:154-62. https://doi.org/10.1179/146531204225020472

피인용 문헌

  1. CAD/CAM 전문 인력 양성을 위한 교육 및 업무의 필요성 vol.38, pp.4, 2016, https://doi.org/10.14347/kadt.2016.38.4.365