Abstract
Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.
목적: 새롭게 개발된 인상채득이 가능한 치유지대주를 이용한 인상채득과 기존의 임프레션 코핑을 이용한 인상채득을 3차원적으로 비교함으로써 개발된 시스템의 정확성을 평가하였다. 재료 및 방법: 10명의 환자에서 구치부에 임플란트(SuperLine; Dentium, Seoul, Korea)를 식립 후 치유지대주(MyHealing; Raphabio Co., Seoul, Korea)를 연결하였다. 식립 3개월 후 보철물 제작을 위한 인상채득시 인상채득이 가능한 치유지대주를 이용한 transfer 방식과 기존의 인상용 코핑을 이용한 pick-up 방식으로 두 번 인상채득 후 각각 주모형을 제작하였다. 맞춤형 보철 지대주(Myplant; Raphabio Co., Seoul, Korea)를 제작하고 각각의 주모형에 체결 후 치과용 스캐너(Scanner S600; Zirkonzahn, South Tyrol, Italy)로 가상의 모형을 형성하였다. 3차원 분석 프로그램(Geomagic Qualify 12; Geomagic, Morrisville, NC, USA)을 이용하여 두 개의 가상의 모형을 중첩하여 지대주의 위치와 기울기의 차이를 분석하였다. 측정값은 Kruskal Wallis과 Mann-Whitney U test 방법을 통해 분석하였고, 유의수준은 0.05 로 설정하였다. 결과: 두 가지 인상법에 따른 지대주의 위치는 근원심 방향에서 0.032 mm, 협설측 방향에서 0.029 mm, 상하 방향에서 0.023 mm의 차이를 보였다. 기울기는 근원심 방향에서 $0.755^{\circ}$, 협설측 방향에서 $1.275^{\circ}$, 상하 방향에서 $0.420^{\circ}$의 차이를 보였다. 결론: 인상채득이 가능한 치유지대주를 이용한 인상채득 방식은 기존의 전통적인 인상용 코핑을 이용한 방식과 비교 시 0.032 mm 이내의 차이를 보였고 기존 논문과의 비교 시 유사한 수치이다.