Abstract

The usage of anchors has increased in joints of new and old concretes for the purposes of seismic retrofits, remodeling, strengthening of existing structures, and so on. In most cases, the shear capacities of the anchors are governed by the steel strength of anchor rods. A lot of anchors should be installed to develop full strength of new structures. In this study, high-shear-capacity ring anchors consisting of steel ring and rod were developed and their shear capacities were examined through shear tests with varying beam width, concrete compressive strength, embedment depth of anchor rod, ring shape, epoxy types, and anchor types. For the specimens with the shallow width that is less than 3.33 times of the ring diameter, splitting failures occurred with the side cover concrete spalling. In splitting failure, the shear capacity increased as the specimen width increased. For the specimens with the wide width, the ring anchors failed due to bearing and the width did not affect the shear capacity. The shear capacities of the ring anchors are at least 1.75 times and up to 4.37 times of the shear capacity of the rod anchor. In addition, the ring anchors had higher stiffness and in most cases the maximum capacities were developed at 2 mm or less displacement. The improved stiffness may enhance the usage of the ring anchors for seismic retrofits. The embedment depth also affects the shear capacities of the ring anchors. With an embedment depth of 125 mm, the ring anchors have shear capacities of at least 3.3 times of the shear capacity of the rod anchor. Therefore, the number of anchors can be significantly reduced.

Keywords

Acknowledgement

Supported by : 중소기업청

References

  1. 財團法人 日本建築防災協会, "既存鉄筋コンクリート造建築物の耐震改修設計指針同解説", 2001.1
  2. 藤井稔己, 貞末和史, 横山 剛, 石村光由, 南 宏一, "既存低強度コンクリートRC 建物に対するハイブリッド耐震補強工法の適用に関する実験的研究 その 1 接合部要素の実験計画", 日本建築学会 2009年度大会(東北)学術講演梗概集, 2009.
  3. 石村光由, 貞末和史, 横山 剛, 藤井稔己, 南 宏一, "既存低強度コンクリートRC 建物に対するハイブリッド耐震補強工法の適用に関する実験的研究 その 2 接合部要素実験", 日本建築学会 2009年度大会(東北)学術講演梗概集, 2009.
  4. 정주성, 이강석, "기존 중저층 R/C 건물의 내진보강을 위한 RCSF 외부접합공법 제안", 대한건축학회 추계학술발표대회논문집 제34권 제2호, p.p.503-504
  5. 한국콘크리트학회, 콘크리트 구조기준․해설, 기문당, 2012, 599 pp.
  6. ACI Committee 318, "Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary," ACI, Farmington Hills, Mich., USA, 2011, p. 111.
  7. 三輪 明広, "鋼管をコッターとして用いた耐震補強工法 (TO-STC工法) の開発", 戸田建設技術研究報告 第30号, 2008
  8. 石岡拓他 : 鋼管をコッターとして用いた耐震補強工法 (TOSTC工法) の開発 その3 RM ブロック耐震壁, 戸田建設技術研究報告 第34号, 2008
  9. 출원 특허, 충전형 앵커 소켓, 10-2014-0038192, 2014년 3월 31일.
  10. 한국강구조학회, 하중저항계수설계법에 의한 강구조설계기준, 2014, 463 pp.
  11. Fuchs, W., Eligehausen, R. and Breen, J. E.. "Concrete Capacity Design (CCD) Approach for Fastening to Concrete." ACI Structural Journal, Vo. 92, No. 1, 1995, p.p. 73-94.
  12. 財团法人 日本建築防災協會, "外側耐震改修マニュアル", 2002, p. 139.

Cited by

  1. Tensile Strength of Post-Installed High-Shear Ring Anchors (HRA) After Shear Loading vol.18, pp.4, 2018, https://doi.org/10.9712/KASS.2018.18.4.61