과제정보
연구 과제 주관 기관 : Ministry of Science, ICT and Future Planning
참고문헌
- C.M. Eisenhouer, R.B. Schwartz, R.C. McCall, Effect of air scatter on calibration of instruments for detecting neutrons, Radiat. Prot. Dosim. 19 (1987) 77-84.
- C.M. Eisenhouer, Review of scattering corrections for calibration of neutron instruments, Radiat. Prot. Dosim. 28 (1989) 253-262.
-
H. Kluge, K. Weise, J.B. Hunt, Calibration of neutron sensitive spherical devices with bare and
$D_2O$ -moderated$^{252}Cf$ sources in rooms of different sizes, Rad. Prot. Dosim. 32 (1990) 233-244. - International Organization for Standardization (ISO), Reference Neutron Radiations-Part 2: Calibration Fundamentals of Radiation Protection Devices Related to the Basic Quantities Characterizing the Radiation Field, ISO 8529-2, ISO, Geneva, Switzerland, 2000.
- J.B. Hunt, The Calibration and Use of Long Counters for the Accurate Measurement of Neutron Flux Density, NPL Report-RS5, National Physical Laboratory, Teddington, United Kingdom, 1976.
- J.B. Hunt, The calibration of neutron sensitive spherical devices, Radiat. Prot. Dosim. 8 (1984) 239-251.
- C.M. Eisenhouer, J.B. Hunt, R.B. Schwartz, Calibration techniques for neutron personal dosimetry, Radiat. Prot. Dosim. 10 (1985) 43-57. https://doi.org/10.1093/oxfordjournals.rpd.a079410
- B.H. Kim, S.I. Kim, J.S. Kim, J.L. Kim, J.I. Lee, Response of several neutron measuring devices under the fractional change of thermal and fast neutrons, Radiat. Meas. 45 (2010) 1541-1543. https://doi.org/10.1016/j.radmeas.2010.04.007
- M. Reginatto, P. Goldhagen, MAXED, a computer code for maximum entropy deconvolution of multisphere neutron spectrometer data, Health Phys. 77 (1999) 579-583. https://doi.org/10.1097/00004032-199911000-00012
- M. Reginatto, P. Goldhagen, S. Neumann, Spectrum unfolding, sensitivity analysis and propagation of uncertainties with the maximum entropy deconvolution code MAXED, Nucl. Instrum. Methods Phys. A 476 (2002) 242-246. https://doi.org/10.1016/S0168-9002(01)01439-5
- International Commission on Radiation Units and Measurements (ICRU), Conversion coefficients for use in radiological protection against external radiation, ICRU Report 57, ICRU, Bethesda, MD, USA, 1998.
- S.I. Kim, B.H. Kim, I. Chang, J.I. Lee, J.L. Kim, A.S. Pradhan, Response of six neutron survey meters in mixed fields of fast and thermal neutrons, Radiat. Prot. Dosim. 156 (2013) 518-524. https://doi.org/10.1093/rpd/nct103
피인용 문헌
- Characterization of NIS neutron irradiation facility for calibration and metrological application vol.12, pp.None, 2015, https://doi.org/10.1051/ijmqe/2021007