Abstract
The change in induced voltage according to the relationship of ground connection between the aluminum sheath layer and a conductor pair in a general telecommunication cable is analyzed. When a measurement is practiced under the condition of separated sheath grounds with an averaged ground resistance of $42.6{\Omega}$, the induced voltage decreases 10 % to the induced voltage without sheath grounds. The induced voltage decreases approximately 50 % in the case of a one-sided common ground and decreases by more than 90 % in the case of a both-sided common ground. This experimental result is similar to the values calculated using the methods of the ITU Directives. In addition, according to a comparison analysis utilizing this ITU method, the measurement error range will be below 10 % in the state of ground resistance of central office less than $10{\Omega}$ and for the terminal side with $100{\Omega}$ less or more.
통신 회선에 대한 전력선 전자유도 전압을 측정할 때, 일반 통신 케이블의 쉬스 층 및 측정 대상 통신 회선 접지의 상호 접속 관계에 따른 전압 변화를 비교 분석하였다. 케이블 양측 쉬스 접지 저항이 평균 $42.6{\Omega}$으로 유사한 상태에서 쉬스를 분리 접지하고 유도 전압을 측정하면 쉬스 접지를 하지 않은 상태에서 측정한 유도 전압에 대하여 10 % 미만 감소된다. 어느 한 쪽을 공통으로 접지하면 약 50 % 감소되고 양측을 모두 공통으로 하면 90 % 넘게 감소된다. 이것은 국제전기통신연합(ITU)에서 제공하는 계산식으로 계산하였을 때의 결과와 유사한 것으로 분석되었다. 아울러 ITU의 계산식을 활용하여 양측 쉬스 접지 저항 값을 변화시킬 때의 유도 전압 변화를 시뮬레이션하여 비교 분석한 결과, 실제 현장에서 쉬스 접지 저항 기준이 $100{\Omega}$이고 전화 국사의 저항이 보통 $10{\Omega}$ 이하인 점을 감안할 때 측정 오차율은 약 10 % 이하가 된다.