Abstract

Local wall thinning and integrity degradation caused by several mechanisms, such as flow accelerated corrosion, cavitation, flashing and/or liquid droplet impingement, is a main concern in secondary steam cycle piping system of nuclear power plants in terms of safety and operability. Thinned pipe management program (TPMP) has being developed and optimized to reduce the possibility of unplanned shutdown and/or power reduction due to pipe failure caused by wall thinning. In this paper, newest technologies, standards and regulations related to the integrity assessment, repair and replacement of thinned pipe component are reviewed. And technical improvement items in TPMP to secure the reliability and effectiveness are also presented.

Keywords

References

  1. EPRI, 1996, "Flow Accelerated Corrosion in Power Plants," TR-106611-R1
  2. EPRI, 2006, "Recommendations for an Effective FAC Program," NSAC-202L-R3
  3. ASME, 2003, "Requirements for Analytical Evaluation of Pipe Wall Thinning," Code Case N-597-2
  4. KEPIC, 2007, "General Mechanical Components-Piping," MNC(ASME NC 2005 Addenda), Korea Electric Association
  5. KEPIC, 2007, "General Mechanical Components-Piping," MND(ASME NC 2004 Edition), Korea Electric Association
  6. KEPIC, 2007, "General Mechanical Components-Piping," MGE(ASME B31.1 2004 Edition), Korea Electric Association
  7. EPRI, 2009, "Application of the New ASME Design Margin to the Assessment of FAC-Induced Wall Thinning in Piping Systems," TR-1018467
  8. Lee, S. H., Lee, J. K and Park, C. Y., 2010, "Behavior of Elastic and Plastic Limit Load of Thinned Elbow in Real Scale Failure Test under Combined Load," Trans. of KSME(A), Vol. 34, No. 9, pp. 1293-1298
  9. Kim, J. W., Lee, S. H. and Park, C. Y., 2009, "Experimental evaluation of the effect of local wall thinning on the failure pressure of elbows," Nuclear Engineering and Design, 239, pp. 2737-2746 https://doi.org/10.1016/j.nucengdes.2009.10.003
  10. KEPIC, 2011, "Repair of Pressure Equipment and Piping", MMR (ASME PCC-2-2008 Edition), Korea Electric Association
  11. ASME, 2007, "Alternative Requirements for Wall Thickness Restoration of Class 2 and High Energy Class 3 Carbon Steel Piping," CC N-561-2
  12. ASME, 2007, "Alternative Requirements for Wall Thickness Restoration of Class 3 Moderate Carbon Steel Piping," CC N-562-2
  13. ASME, 2007, "Alternative Requirements for Wall Thickness Restoration of Class 2 and 3 Carbon Steel Piping for Raw Water Service," CC N-661-2
  14. US NRC, 2014, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1," Regulatory Guide 1.147