DOI QR코드

DOI QR Code

Wire or Hook Traction for Reducing Zygomatic Fracture

  • Ahn, Hee Chang (Department of Plastic and Reconstructive Surgery, Hanyang University Medical Center, Hanyang University College of Medicine) ;
  • Youn, Dong Hyun (Department of Plastic and Reconstructive Surgery, Hanyang University Medical Center, Hanyang University College of Medicine) ;
  • Choi, Matthew Seung Suk (Department of Plastic and Reconstructive Surgery, Hanyang University Guri Hospital, Hanyang University College of Medicine) ;
  • Chang, Jung-Woo (Department of Plastic and Reconstructive Surgery, Hanyang University Guri Hospital, Hanyang University College of Medicine) ;
  • Lee, Jang Hyun (Department of Plastic and Reconstructive Surgery, Hanyang University Guri Hospital, Hanyang University College of Medicine)
  • 투고 : 2015.06.12
  • 심사 : 2015.11.01
  • 발행 : 2015.12.09

초록

Background: Variable methods have been introduced for reduction of the zygomatic fractures. The Dingman elevator is used widely to reduce these fractures but is inappropriate in certain types of fractures which require atypical traction vectors. We introduce and examine an alternate method of reducing zygomatic fractures using wire and hook traction. Methods: A retrospective study was performed for all zygomatic fracture patients admitted between 2008 and 2014. Medially rotated fractures were reduced by using a wire looped through an intermaxillary screw secured on the medial side of the zygoma. Laterally rotated fractures were reduced using a hook introduced through an infrazygomatic skin incision. Results: No accidental bleeding or incomplete reduction was observed in any of the cases. Postoperative imaging demonstrated proper reduction immediately after the operation. Follow-up computed tomography study at 1 month after operation also demonstrated proper reduction and healthy union across the previous site of fracture. Conclusion: The hook and wire method allowed precise application of traction forces across zygomatic fractures. The fractured bone fragment could be pulled in the direction precisely opposite to the vector of impact at the time of trauma. Soft tissue damage due to dissection was minimized. In particular, this method was effective in reducing rotated bone fragments and can be an alternative option to using the zygoma elevator.

키워드

참고문헌

  1. Kelley P, Hopper R, Gruss J. Evaluation and treatment of zygomatic fractures. Plast Reconstr Surg 2007;120(7 Suppl 2):5S-15S.
  2. Ellstrom CL, Evans GR. Evidence-based medicine: zygoma fractures. Plast Reconstr Surg 2013;132:1649-57. https://doi.org/10.1097/PRS.0b013e3182a80819
  3. Meslemani D, Kellman RM. Zygomaticomaxillary complex fractures. Arch Facial Plast Surg 2012;14:62-6. https://doi.org/10.1001/archfacial.2011.1415
  4. Knight JS, North JF. The classification of malar fractures: an analysis of displacement as a guide to treatment. Br J Plast Surg 1961;13:325-39.
  5. Yamamoto K, Matsusue Y, Horita S, et al. Clinical analysis of midfacial fractures. Mater Sociomed 2014;26:21-5. https://doi.org/10.5455/msm.2014.26.21-25
  6. Salentijn EG, van den Bergh B, Forouzanfar T. A ten-year analysis of midfacial fractures. J Craniomaxillofac Surg 2013;41:630-6. https://doi.org/10.1016/j.jcms.2012.11.043
  7. Hanemann M Jr, Simmons O, Jain S, et al. A comparison of combinations of titanium and resorbable plating systems for repair of isolated zygomatic fractures in the adult: a quantitative biomechanical study. Ann Plast Surg 2005;54:402-8. https://doi.org/10.1097/01.sap.0000151484.59846.62
  8. Becelli R, Quarato D, Matarazzo G, et al. Esthetic positioning of rigid internal fixation in tripod zygomatic fractures: an innovative surgical technique. J Craniofac Surg 2009;20:724-5. https://doi.org/10.1097/SCS.0b013e3181a2efc2
  9. Matsuda K, Kubo T, Kawai K, et al. Use of hook screws in facial bone reduction. Plast Reconstr Surg 2005;115:1436-8.
  10. Kim MG, Yoo RE, Chang H, et al. An intermaxillary fixation screw traction wire: an aid for facial bone fracture repair. Ann Plast Surg 2009;63:71-3. https://doi.org/10.1097/SAP.0b013e3181877b43
  11. Moon SH, Lee JH, Oh DY, et al. Reduction of zygomatic fracture segment with intermaxillary fixation screw. J Craniofac Surg 2012;23: 842-4. https://doi.org/10.1097/SCS.0b013e31824dbeb8
  12. Rao S, Rao S. Use of mono cortical screws as an aid to zygomatic complex fracture reduction. J Maxillofac Oral Surg 2015;14:126-7. https://doi.org/10.1007/s12663-013-0589-1
  13. O'Regan B, Devine M. Screw-wire traction technique: aid to anatomical reduction of multi-segment mid-facial fractures. Br J Oral Maxillofac Surg 2013;51:459-60. https://doi.org/10.1016/j.bjoms.2012.10.016
  14. Park BY, Song SY, Yun IS, et al. First percutaneous reduction and next external suspension with Steinmann pin and Kirschner wire of isolated zygomatic fractures. J Craniofac Surg 2010;21:1060-5. https://doi.org/10.1097/SCS.0b013e3181e62cb2
  15. Uda H, Kamochi H, Sugawara Y, et al. The concept and method of closed reduction and internal fixation: a new approach for the treatment of simple zygoma fractures. Plast Reconstr Surg 2013;132:1231-40. https://doi.org/10.1097/PRS.0b013e3182a48d8c
  16. Baek JE, Chung CM, Hong IP. Reduction of zygomatic fractures using the carroll-girard T-bar screw. Arch Plast Surg 2012;39:556-60. https://doi.org/10.5999/aps.2012.39.5.556
  17. Ward Booth P, Hausamen JE, Schendel SA. Maxillofacial surgery. St. Louis, Mo.: Churchill Livingstone/Elsevier; 2007.
  18. Czerwinski M, Martin M, Lee C. Quantitative comparison of open reduction and internal fixation versus the Gillies method in the treatment of orbitozygomatic complex fractures. Plast Reconstr Surg 2005;115:1848-54. https://doi.org/10.1097/01.PRS.0000165079.36556.57
  19. Sargent LA, Fernandez JG. Incidence and management of zygomatic fractures at a level I trauma center. Ann Plast Surg 2012;68:472-6. https://doi.org/10.1097/SAP.0b013e31823d2c6b

피인용 문헌

  1. Surgical Methods of Zygomaticomaxillary Complex Fracture vol.17, pp.4, 2015, https://doi.org/10.7181/acfs.2016.17.4.206