DOI QR코드

DOI QR Code

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography

소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안

  • Park, Chanhyuk (Department of Radiology, Pusan National University Yangsan Hospital) ;
  • Lee, Jaeseung (Department of Radiological Science, Dongeui University) ;
  • Im, Inchul (Department of Radiological Science, Dongeui University)
  • 박찬혁 (양산부산대학교병원 영상의학과) ;
  • 이재승 (동의대학교 방사선학과) ;
  • 임인철 (동의대학교 방사선학과)
  • Received : 2014.06.10
  • Accepted : 2014.10.25
  • Published : 2014.10.30

Abstract

This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.

본 연구는 소아 심장 전산화단층촬영 검사에서 조영제의 과다 사용을 최소화하며 피폭 선량 저감화를 목적으로 조영제의 주입속도 및 심장 도달 시간 등의 변수를 고려한 스캔 지연 시간을 경험론적 방법으로 수식화함으로써 4개의 심방과 심실이 동시 조영증강 영상을 획득할 수 있는 최적화 방안을 제시하고자 하였다. 소아 심장전산화단층 검사를 시행한 소아 환자 30명을 대상으로 정성적 평가, 정량적 평가, 선량평가를 실시하였다. 결론적으로 본 연구에서 개발한 체중에 따른 조영제 양과 주입속도에 따른 스캔 지연 시간을 계산하는 경험론적 방법을 적용함으로써 왼 오른 심방과 심실의 동시 조영증강에서 소아 심장 판독에 적합한 300 HU 값 이상으로 나타났고 명확성, 선예도, 노이즈에 대한 정성적 영상 평가에서 질적 우수성을 보였으며 선량평가에서도 소아가 받는 피폭선량도 명확하게 감소되었다. 따라서 본 연구는 임상에서 조영제 과다 사용으로 인한 부작용 감소 효과를 기대 할 수 있었으며 방사선 피폭 저감화를 기대 할 수 있는 이점을 가지고 최적의 영상을 만드는데 중요한 역할을 할 것으로 판단되었다.

Keywords

References

  1. M. Satpathy, "Clinical diagnosis of congenital heart disease", 1st edit., Jaypee Brothers Publishers Ltd., New Delhi, pp. 22-24, 2008.
  2. P. Daubeney, M. Rigby, M. Gatzoulis, M. Niwa, "Pediatric heart disease: a clinical guide", 1st edit., John Wiley & Sons., Oxford, UK, pp. 142-145, 2012.
  3. U. J. Schoepf, C. R. Becker, B. M. Ohnesorge, E. K. Yucel, "CT of Coronary Artery Disease", Radiology, Vol. 232, No. 1, pp. 18-37, 2004. https://doi.org/10.1148/radiol.2321030636
  4. H. W. Goo, "State of the Art CT Imaging Techniques for Congenital Heart Disease", Korean J Radiol., Vol. 11, No. 1, pp.4-18, 2010. https://doi.org/10.3348/kjr.2010.11.1.4
  5. M. J. Siegel, S. Bhalla, F. R. Gutierrez, et al., "MDCT of postoperative anatomy and complications in adults with cyanotic heart disease" AJR. Am. J. Roentgenol., Vol. 184, No. 1, pp. 241-247, 2005. https://doi.org/10.2214/ajr.184.1.01840241
  6. B. K. Han, J. Lindberg, K. Grant, R. S. Schwartz, J. R. Lesser, "Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease", Am. J. Cardiol., Vol. 107, No. 10, pp. 1541-1546, 2011. https://doi.org/10.1016/j.amjcard.2011.01.065
  7. D. P. Frush, J. R. Herlong, "Pediatric thoracic CT angiography", Pediatr. Radiol., Vol. 35, No. 1, pp. 11-25, 2005. https://doi.org/10.1007/s00247-004-1348-8
  8. P. Dawson, M. Blomley, "The value of mathematical modelling in understanding contrast enhancement in CT with particular reference to the detection of hypovascular liver metastases", Eur. J. Radiol., Vol. 41, No. 3, pp. 222-236, 2002. https://doi.org/10.1016/S0720-048X(01)00454-5
  9. K. T. Bae, "Peak contrast enhancement in CT and MR angiography: when does it occur and why? pharmacokinetic study in a porcine model", Radiology, Vol. 227, No. 3, pp.809-816, 2003. https://doi.org/10.1148/radiol.2273020102
  10. S. T. Schindera, R. C. Nelson, L. Howle, E. Nichols, D. M. DeLong, E. M. Merkle, "Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study", Eur. Radiol., Vol. 18, No. 8, pp. 1683-1689, 2008. https://doi.org/10.1007/s00330-008-0911-3
  11. P. Dawson, M. Blomley, "The value of mathematical modelling in understanding contrast enhancement in CT with particular reference to the detection of hypovascular liver metastases", Eur J Radiol., Vol. 41, No. 3, pp. 222-236, 2002. https://doi.org/10.1016/S0720-048X(01)00454-5
  12. D. P. Frush, J. R. Herlong, "Pediatric thoracic CT angiography", Pediatr. Radiol., Vol. 35, No. 1, pp. 11-25, 2005. https://doi.org/10.1007/s00247-004-1348-8

Cited by

  1. 심박동수 변이에 따른 심혈관질환 위험 인자와의 관련성에 미치는 영향 분석 vol.12, pp.3, 2014, https://doi.org/10.7742/jksr.2018.12.3.321