DOI QR코드

DOI QR Code

Evaluation of Portable Slipmeter using Human Perception

인간의 인지적 감각을 이용한 휴대용 미끄럼 측정기의 성능평가

  • Choi, Hyung Jin (Applied Science and new Technology for LINK, Dankook University) ;
  • Kim, Jung Soo (Dept. of Safety Engineering, OSHRI, Annex Research Institute, GemsKorea)
  • 최형진 (단국대학교 링크사업단) ;
  • 김정수 ((주)한국젬스, 산업안전보건연구원)
  • Received : 2014.06.19
  • Accepted : 2014.09.20
  • Published : 2014.09.30

Abstract

The objectives of this study were to evaluate the safe criteria of portable slipmeter using human perception onto the several different floor surfaces under contaminated conditions. It was difficult to find why many different slipmeters took there's own safe criteria. It is still unclear how thres hold values established in many literatures. Two different subjective slippery evaluating methods, AHP(Analytic Hierarchy Process) and Friedman test,were used to evaluate the perception of slipperiness of seven different floor surfaces under the contaminated condition with detergent solution. Twelve subjects worn same footwear and walked with self-selected step and cadence along the test floors. The SCOF(Static Coefficient of Friction) obtained for same test conditions with BOT-3000 was compared to perception of slipperiness to establish as a safe criteria. The very high significant correlation(r=0.97) was found between AHP and Friedman test. Also, The high significant correlation(r=0.96) was found between AHP and SCOF obtained with BOT-3000. The results suggested that the SCOF should be greater than 0.63 for safer walking. Perception rating obtained with AHP showed a high correlation with Friedman test and the SCOF obtained with BOT-3000 except for polished tile floor. The safe criteria obtained through this study were similar to ANSI/NFSIB101.1.

Keywords

References

  1. Kim, J.S.,et. al(2007). The study for slip and trip assessment tool development. OSHRI report 2007-119-1048, KOSHA.
  2. Kim, J.S.,et.al(2010). Development of slip resistance criteria and device for safety shoes. OSHRI report 2010-157-1065, KOSHA.
  3. Gronqvist, R., Hirvonen, M., Tohv A(1999). Evaluation of three portable floor slipperiness testers. Int. J Industrial Ergonomics. 25. pp. 85-95.
  4. Chang W.R., Cotnam J.P., Matz S(2003). Field evaluation of two commonly used slipmeters. Applied Ergonomics. 34. pp. 51- 60. https://doi.org/10.1016/S0003-6870(02)00074-1
  5. Ricotti R., Deucchi M., Cerisola G(2009). A comparison of results from portable and laboratory floor slipperiness testers. Int. J Industrial Ergonomics. 39. pp. 353-357. https://doi.org/10.1016/j.ergon.2008.07.004
  6. ANSI(2009). Test Method for Measuring Wet SCOF of Common Hard Surface Floor Materials. ANSI/NFSI B101.1.
  7. Dura J., Alcantara E., Zamora T., Balaguer E., Rosa D(2005). Identification of floor safety level for public buildings considering mobility disabled people needs. Safety Science. 43. pp. 407-423. https://doi.org/10.1016/j.ssci.2005.08.003
  8. Gao C., Abeysekera J(2002). The assessment of the integration of slip resistance, thermal insulation and wearability of footwear on icy surfaces. Safety Science. 40. pp. 613-624. https://doi.org/10.1016/S0925-7535(01)00062-5
  9. Saaty T.L(2008). Decision making with the analytic hierarchy process. Int. J. Services Sciences. 1(1). pp. 83-98. https://doi.org/10.1504/IJSSCI.2008.017590
  10. Burnfield J.M., Power C.M(2002). Influence of age and gender on utilized coefficient of friction during walking at different speeds. In Marpet M.I. and Sapienza M.A. (Eds), Metrology of Pedestrian Locomotion and Slip Resistance (ASTM Stock Number : STP 1424), ASTM International,West Conshohocken. pp. 3-16.