References
- Rangert B, Krogh PH, Langer B, Van Roekel N. Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants 1995;10:326-34.
- Hobkirk JA, Havthoulas TK. The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures. J Prosthet Dent 1998;80:169-74. https://doi.org/10.1016/S0022-3913(98)70106-4
- Stanford CM. Biomechanical and functional behavior of implants. Adv Dent Res 1999;13:88-92. https://doi.org/10.1177/08959374990130012101
- Schwartz-Arad D, Levin L. Intraoral autogenous block onlay bone grafting for extensive reconstruction of atrophic maxillary alveolar ridges. J Periodontol 2005;76:636-41. https://doi.org/10.1902/jop.2005.76.4.636
- Maiorana C, Santoro F. Maxillary and mandibular bone reconstruction with hip grafts and implants using Frialit-2 implants. Int J Periodontics Restorative Dent 2002;22:221-9.
- Simion M, Trisi P, Piattelli A. Vertical ridge augmentation using a membrane technique associated with osseointegrated implants. Int J Periodontics Restorative Dent 1994;14:496-511.
- Chiapasco M, Lang NP, Bosshardt DD. Quality and quantity of bone following alveolar distraction osteogenesis in the human mandible. Clin Oral Implants Res 2006;17:394-402. https://doi.org/10.1111/j.1600-0501.2005.01247.x
- Engelke WG, Diederichs CG, Jacobs HG, Deckwer I. Alveolar reconstruction with splitting osteotomy and microfixation of implants. Int J Oral Maxillofac Implants 1997;12:310-8.
- Becker CM, Kaiser DA. Surgical guide for dental implant placement. J Prosthet Dent 2000;83:248-51. https://doi.org/10.1016/S0022-3913(00)80018-9
- Almog DM, Torrado E, Meitner SW. Fabrication of imaging and surgical guides for dental implants. J Prosthet Dent 2001;85:504-8. https://doi.org/10.1067/mpr.2001.115388
- Garber DA. The esthetic dental implant: letting restoration be the guide. J Am Dent Assoc 1995;126:319-25. https://doi.org/10.14219/jada.archive.1995.0175
- Pesun IJ, Gardner FM. Fabrication of a guide for radiographic evaluation and surgical placement of implants. J Prosthet Dent 1995;73:548-52. https://doi.org/10.1016/S0022-3913(05)80114-3
- Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol 2005;76:503-7. https://doi.org/10.1902/jop.2005.76.4.503
- Sarment DP, Al-Shammari K, Kazor CE. Stereolithographic surgical templates for placement of dental implants in complex cases. Int J Periodontics Restorative Dent 2003;23:287-95.
- van Steenberghe D, Naert I, Andersson M, Brajnovic I, Van Cleynenbreugel J, Suetens P. A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. Int J Oral Maxillofac Implants 2002;17:663-70.
- Sarment DP, Sukovic P, Clinthorne N. Accuracy of implant placement with a stereolithographic surgical guide. Int J Oral Maxillofac Implants 2003;18:571-7.
- Van Assche N, van Steenberghe D, Guerrero ME, Hirsch E, Schutyser F, Quirynen M, et al. Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. J Clin Periodontol 2007;34:816-21. https://doi.org/10.1111/j.1600-051X.2007.01110.x
- Fortin T, Champleboux G, Lormee J, Coudert JL. Precise dental implant placement in bone using surgical guides in conjunction with medical imaging techniques. J Oral Implantol 2000;26:300-3. https://doi.org/10.1563/1548-1336(2000)026<0300:PDIPIB>2.3.CO;2
- Fortin T, Champleboux G, Bianchi S, Buatois H, Coudert JL. Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine. Clin Oral Implants Res 2002;13:651-6. https://doi.org/10.1034/j.1600-0501.2002.130612.x
- Klein M, Abrams M. Computer-guided surgery utilizing a computer-milled surgical template. Pract Proced Aesthet Dent 2001;13:165-9.
- Widmann G, Widmann R, Widmann E, Jaschke W, Bale R. Use of a surgical navigation system for CT-guided template production. Int J Oral Maxillofac Implants 2007;22:72-8.
- Valente F, Schiroli G, Sbrenna A. Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. Int J Oral Maxillofac Implants 2009;24:234-42.
- Ersoy AE, Turkyilmaz I, Ozan O, McGlumphy EA. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. J Periodontol 2008;79:1339-45. https://doi.org/10.1902/jop.2008.080059
- D'haese J, Van De Velde T, Komiyama A, Hultin M, De Bruyn H. Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. Clin Implant Dent Relat Res 2012;14:321-35. https://doi.org/10.1111/j.1708-8208.2010.00275.x
- Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hammerle CH, et al. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 2009;24 Suppl:92-109.
- Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 2014;29 Suppl:25-42. https://doi.org/10.11607/jomi.2014suppl.g1.2
-
De Bruyn H, Atashkadeh M, Cosyn J, van de Velde T. Clinical outcome and bone preservation of single
$TiUnite^{TM}$ implants installed with flapless or flap surgery. Clin Implant Dent Relat Res 2011;13:175-83. https://doi.org/10.1111/j.1708-8208.2009.00200.x - Jensen OT, Cullum DR, Baer D. Marginal bone stability using 3 different flap approaches for alveolar split expansion for dental implants: a 1-year clinical study. J Oral Maxillofac Surg 2009;67:1921-30. https://doi.org/10.1016/j.joms.2009.04.017
- Wood DL, Hoag PM, Donnenfeld OW, Rosenfeld LD. Alveolar crest reduction following full and partial thickness flaps. J Periodontol 1972;43:141-4. https://doi.org/10.1902/jop.1972.43.3.141
- Rousseau P. Flapless and traditional dental implant surgery: an open, retrospective comparative study. J Oral Maxillofac Surg 2010;68:2299-306. https://doi.org/10.1016/j.joms.2010.05.031
- Brodala N. Flapless surgery and its effect on dental implant outcomes. Int J Oral Maxillofac Implants 2009;24 Suppl:118-25.
- Sclar AG. Guidelines for flapless surgery. J Oral Maxillofac Surg 2007;65(7 Suppl 1):20-32.
- Pettersson A, Kero T, Gillot L, Cannas B, Faldt J, Soderberg R, et al. Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I. J Prosthet Dent 2010;103:334-42. https://doi.org/10.1016/S0022-3913(10)60072-8
- Widmann G, Zangerl A, Keiler M, Stoffner R, Bale R, Puelacher W. Flapless implant surgery in the edentulous jaw based on three fixed intraoral reference points and image-guided surgical templates: accuracy in human cadavers. Clin Oral Implants Res 2010;21:835-41.
- Schneider D, Marquardt P, Zwahlen M, Jung RE. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clin Oral Implants Res 2009;20 Suppl 4:73-86. https://doi.org/10.1111/j.1600-0501.2009.01788.x
- Van Assche N, van Steenberghe D, Quirynen M, Jacobs R. Accuracy assessment of computer-assisted flapless implant placement in partial edentulism. J Clin Periodontol 2010;37:398-403. https://doi.org/10.1111/j.1600-051X.2010.01535.x
- Ozan O, Turkyilmaz I, Ersoy AE, McGlumphy EA, Rosenstiel SF. Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. J Oral Maxillofac Surg 2009;67:394-401. https://doi.org/10.1016/j.joms.2008.09.033
- Widmann G, Bale RJ. Accuracy in computer-aided implant surgery: a review. Int J Oral Maxillofac Implants 2006;21:305-13.
- Cassetta M, Stefanelli LV, Giansanti M, Di Mambro A, Calasso S. Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide. Int J Oral Maxillofac Surg 2011;40:1377-87. https://doi.org/10.1016/j.ijom.2011.09.009
- D'haese J, Van De Velde T, Elaut L, De Bruyn H. A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae. Clin Implant Dent Relat Res 2012;14:293-303. https://doi.org/10.1111/j.1708-8208.2009.00255.x
Cited by
- An Intraoperative Site-specific Bone Density Device: A Pilot Test Case vol.16, pp.8, 2014, https://doi.org/10.5005/jp-journals-10024-1743
- 새로 개발된 3차원 영상 기반의 임플란트 가이드 프로그램과 삭제 공정을 이용한 임플란트 계획 및 식립: 증례보고 vol.31, pp.1, 2014, https://doi.org/10.14368/jdras.2015.31.1.67
- Computer-aided flapless implant surgery and immediate loading. A technical note vol.20, pp.3, 2014, https://doi.org/10.1007/s10006-016-0554-5
- 3D Printing Guide Implant Placement: A Case Report vol.21, pp.1, 2014, https://doi.org/10.1515/bjdm-2017-0010
- A Flapless Surgical Placement of Implants in Mandibular Arch Using Computer-Guided Surgical Stent vol.9, pp.1, 2014, https://doi.org/10.1177/2229411218766969
- 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study vol.22, pp.6, 2014, https://doi.org/10.1007/s00784-018-2339-8
- Potential Deviation Factors Affecting Stereolithographic Surgical Guides : A Systematic Review vol.28, pp.1, 2014, https://doi.org/10.1097/id.0000000000000853
- Distribution of Trabecular Bone Density in the Maxilla and Mandible vol.28, pp.4, 2014, https://doi.org/10.1097/id.0000000000000893
- The accuracy of computer‐guided implant surgery with tooth‐supported, digitally designed drill guides based on CBCT and intraoral scanning. A prospective cohort study vol.30, pp.10, 2014, https://doi.org/10.1111/clr.13514
- A New Methodology for the Digital Planning of Micro-Implant-Supported Maxillary Skeletal Expansion vol.13, pp.None, 2014, https://doi.org/10.2147/mder.s247751
- Expectation and reality of guided implant surgery protocol using computer-assisted static and dynamic navigation system at present scenario: Evidence-based literature review vol.24, pp.5, 2014, https://doi.org/10.4103/jisp.jisp_92_20
- Fully Digital Workflow for Planning Static Guided Implant Surgery: A Prospective Accuracy Study vol.9, pp.4, 2014, https://doi.org/10.3390/jcm9040980
- Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans vol.12, pp.4, 2014, https://doi.org/10.1111/os.12729
- Die dynamische Navigation mit X-Guide - Erfahrungen zu einer neuen Implantationstechnik vol.129, pp.9, 2020, https://doi.org/10.1055/a-1227-2658
- Computer-guided implant placement associated with computer-aided bone regeneration in the treatment of atrophied partially edentulous alveolar ridges: A proof-of-concept study vol.16, pp.1, 2021, https://doi.org/10.1016/j.jds.2020.02.010
- Accuracy evaluation of computer-guided implant surgery associated with prototyped surgical guides vol.125, pp.2, 2014, https://doi.org/10.1016/j.prosdent.2019.07.010
- A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone vol.14, pp.16, 2014, https://doi.org/10.3390/ma14164631