Analysis and Design of Continuous Current Mode Tapped-Inductor Boost Converter

전류연속 모드 탭인덕터 부스트 컨버터의 분석과 설계

  • Received : 2013.12.12
  • Accepted : 2014.05.22
  • Published : 2014.08.20

Abstract

As the turns ratio of the tapped-inductor contributes to the step-up ratio, the tapped-inductor boost (TIB) converter has significantly increased level of difficulties in its analysis and design compared to the conventional boost converter where the duty ratio is the sole factor affecting the step-up ratio. In this paper, the operation of the continuous current mode TIB converter is briefly reviewed, the characteristics are analyzed in detail, and a design guideline optimizing the loss in the tapped-inductor is presented with a practical design example. Finally, experimental results from a 12V/120V prototype for 0.25A LED driver application are also presented to confirm the design.

Keywords

References

  1. S. Misak and L. Prokop, "Off-grid Power Systems," in Proc. EEEIC, pp. 14-17, 2010.
  2. D. Frame et al., "A Community Based Approach for Sustainable Off-Grid PV Systems in Developing Countries," in Proc. IEEE Power and Energy Society General Meeting, pp. 1-7, 2011.
  3. A. A. Freitas et al., "Off-Grid PV System to Supply a Rural School on DC Network," in Proc. ICREPQ, No. 535, 2010.
  4. (2013). Global LEAP awards [Online]. Available: http://www.globalleapawards.org.
  5. N. Vazquez, L. Estrada, C. Hernandez, and E. Rodriguez, "The Tapped-Inductor Boost Converter," in Proc. ISIE, pp. 538-543, 2007.
  6. J.-M. Kang, S.-H. Lee, S.-S. Hong, and S.-K. Han, "Voltage Clamped Tapped-Inductor Boost Converter with High Voltage Conversion Ratio," Trans. of KIPE, Vol. 17, No. 1, pp. 34-40, Feb. 2012. https://doi.org/10.6113/TKPE.2012.17.1.34
  7. J.-i. Kang, S.-K. Han, and J. Han, "Design of Tapped-Inductor Boost Converter Operating in Continuous Conduction Mode," in Proc. KIPE Annual Fall Conference, pp. 1-2, 2013.
  8. D.-H. Jang, J.-I. Kang, and S.-K. Han, "High Efficiency Lossless Snubber for Photovoltaic Maximum Power Point Tracker," Trans. of KIPE, Vol. 18. No. 5, pp. 485-491, Oct. 2013. https://doi.org/10.6113/TKPE.2013.18.5.485
  9. C.-J. Tseng and C.-L. Chen, "A Passive Lossless Snubber Cell for Nonisolated PWM DC/DC Converters," IEEE Trans. Ind. Electron., Vol. 45, No. 4, pp. 593-601, Aug. 1998. https://doi.org/10.1109/41.704887
  10. R. T. H. Li and H. S.-H. Chung, "A Passive Lossless Snubber Cell With Minimum Stress and Wide Soft-Switching Range," IEEE Trans. Power Electron., Vol. 25, No. 7, pp. 1725-1783, Jul. 2010. https://doi.org/10.1109/TPEL.2010.2042074
  11. K. M. Smith, Jr. and K. M. Smedley, "Engineering Design of Lossless Passive Soft Switching Methods for PWM Converters. I. With Minimum Voltage Stress Circuit Cells," IEEE Trans. Power Electron., Vol. 16, No. 3, pp. 336-344, May 2001. https://doi.org/10.1109/63.923765
  12. J.-i. Kang, S.-K. Han, and J. Han, "Non-dissipative Snubber for Tapped-Inductor Boost Converter in Continuous Conduction Mode for High Step-up Application," in Proc. KIPE Annual Fall Conference, pp. 3-4, 2013.