Abstract

Heliostat field control algorithm is the logics to operate the heliostat field of tower type solar thermal power plant and it could include various methodologies of how to control the heliostat field so as to optimize the energy collection efficiency as well as to reduce the system operating cost. This work, as the first part of the consecutive works, presents heliostat aiming mint allocation scheme which will be used in the heliostat field control algorithm for 200kW solar thermal power plant built in Daegu, Korea. We first discuss the structure of heliostat field control system required for the implementation of aiming scheme developed in this work. Then the methodologies to allocate the heliostat aiming points on the receiver are discussed. The simulated results show that the heliostat aiming point allocation scheme proposed in this work reduces the magnitude of peak heat flux on the receiver more than 40% from the case of which all the heliostats in the field aim at the center of receiver simultaneously. Also it shows that, when the proposed scheme is used, the degradation of heliostat field optical efficiency is relatively small from the maximal optical efficiency the heliostat field could have.

Keywords

References

  1. PIER : California Energy Commission, "Renewable Energy : Solar two central receiver", October 1999
  2. Park M. H., "Introduction of Daegu City Gas Power Tower Project", The Magazine of Korean Solar Energy Society, Vol. 9, No. 2, 2010, pp. 14-18
  3. Park, Y. C., "Design of Heliostat Field for 200kW Tower Type Solar Thermal Power Plant", J. of the Korean Solar Energy Society, Vol. 32, No. 5, 2012, pp. 41-51 https://doi.org/10.7836/kses.2012.32.5.041
  4. Garcia-Martin F. J., Berenguel M., Valverde, A. and Camacho E. F., "Heuristic Knowledge Based Heliostat Field Control for the Optimization of the Temperature Distribution in a Volumetric Receiver", Solar Energy, Vol. 66, No. 5, 1999, pp. 355-369 https://doi.org/10.1016/S0038-092X(99)00024-9
  5. Park, Y. C., "Heliostat Control System", J. of the Korean Solar Energy Society, Vol. 29, No. 1, 2009, pp. 50-57
  6. Hong Y. P. and Park Y. C., "Measurement and Compensation of Heliostat Sun Tracking Error using BCS", J. of Institute of Control. Robotics and Systems, Vol. 18 No. 5, 2012, pp. 502-508 https://doi.org/10.5302/J.ICROS.2012.18.5.502

Cited by

  1. Development of Heliostat Field Operational Algorithm for 200kW Tower Type Solar Thermal Power Plant vol.34, pp.5, 2014, https://doi.org/10.7836/kses.2014.34.5.033