DOI QR코드

DOI QR Code

Project Summary of Three Gorges' 840MVA Hydro-generator with Close-Loop-Self-Circulating Evaporative Cooling System

  • Yuan, Jiayi (College of Electrical and Electronic Engineering, Harbin University of Science and technology) ;
  • Meng, Dawei (College of Electrical and Electronic Engineering, Harbin University of Science and technology) ;
  • Gu, Guobiao (Evaporative Cooling Tech R&D Center, Institute of Electrical Engineering of Chinese Academy of Sciences) ;
  • Song, Fuchuan (Evaporative Cooling Tech R&D Center, Institute of Electrical Engineering of Chinese Academy of Sciences) ;
  • Zhang, Tianpeng (Dongfang Electrical Machinery Co. Ltd.)
  • 투고 : 2013.10.30
  • 심사 : 2013.11.28
  • 발행 : 2014.03.01

초록

In December 2011 and July 2012, two sets of 840MVA hydro-generator of Three Gorges on Yangtze River with Close-loop-self-circulating evaporative cooling (CLSCEC) system were put into commercial operation. In this paper, we make engineering summary of these two generators with CLSCEC system. We also make a comparison between the internal water cooling (IWC) hydro-generator and the CLSCEC hydro-generator used in Three Gorges power plant in fields of their operating characteristics, working performances, technical features, working safety and reliability. In addition, engineering structures, type tests' results and systematic emulating calculation of CLSCEC schemes are analyzed.

키워드

참고문헌

  1. S.N. Ding, Heating and Cooling of Large Electrical Machines, Beijing Science Press, 1992.
  2. G.B. Gu, X.D. Tian, "The Development of Inner Cooling Technology of Hydro-generators," Electric Machines and Control, Vol.1, No.1, pp.46-53, 1997.
  3. G.B. Gu, "New progress of direct cooling in stator winding for large hydro-generators," Proceedings of ICEM, pp.1-6, 1994.
  4. G.B. Gu, N. Xiong, X.D. Tian, J.Y. Yuan, "The development of the 400MW evaporative-cooling hydro-generator of Lijiaxia power station," CIGRE2000 Session Papers Rotating Machines, vol.11, pp.100-102.
  5. Y. Cui, G.B. Gu, J.Y. Yuan, "Simulation and experiment for hydro-generator stator's self circulation evaporative cooling," Advanced Technology of Electrical Engineering and Energy, vol.20, no.2, pp.33-37, 2001
  6. L. Ruan, G.B. Gu, X.D. Tian, Z.Y. Chang, "Experimental research of new coolant in evaporative cooling technique of large generators," Advanced Technology of Electrical Engineering and Energy, vol.21, no.3, pp.21-24, 2002.
  7. Ruan.Lin, Gu.Guobiao, Tian.Xindong, "The comparison of cooling effect between evaporative cooling method and inner water cooling method for the large hydro generator," Proceeding of International Conference on Electrical Machines and Systems, pp.989-992, 2007.