DOI QR코드

DOI QR Code

Constant DC Capacitor Voltage Control based Strategy for Active Load Balancer in Three-phase Four-wire Distribution Systems

  • 투고 : 2014.04.18
  • 심사 : 2014.04.23
  • 발행 : 2014.06.01

초록

Three-phase four-wire distribution systems are used for both three-phase three-wire loads and single-phase two-wire consumer appliances in South Korea, Myanmar and other countries. Unbalanced load conditions frequently occur in these distribution systems. These unbalanced load conditions cause unbalanced voltages for three-phase and single-phase loads, and increase the loss in the distribution transformer. In this paper, we propose constant DC capacitor voltage control based strategy for the active load balancer (ALB) in the three-phase four-wire distribution systems. Constant DC capacitor voltage control is always used in active power line conditioners. The proposed control strategy does not require any computation blocks of the active and reactive currents on the distribution systems. Balanced source-side currents with a unity power factor are obtained without any calculation block of the unbalanced active and reactive components on the load side. The basic principle of the constant DC capacitor voltage control based strategy for the ALB is discussed in detail and then confirmed by both digital computer simulations using PSIM software and prototype experimental model. Simulation and experimental results demonstrate that the proposed control strategy for the ALB can balance the source currents with a unity power factor in the three-phase four-wire distribution systems.

키워드

참고문헌

  1. H. Akagi, Y. Kanazawa and A. Nabe: "Instantaneous reactive power compensators comprising switching devices without energy storage components," IEEE Trans. on Ind. Appl., Vol. IA-20, No. 3 May/June 1984.
  2. A. Nava-Segura and G. Mino-Aguilar: "Four-branchesinverter- based-active-filter for unbalanced 3-phase 4- wires electrical distribution systems," Ind. Appl. Conf., Vol. 4, pp. 2503-2508, 2000.
  3. A. Adya, A.P. Mittal, and J.R.P Gupta, "Modeling and control of DSTATCOM for three-phase four-wire distribution system," IAS Ann. Meeting, Vol.4, pp.2428-2434, 2005.
  4. P. Verdelho and G.D Marques, "An active power filter and unbalanced current compensator," IEEE Trans. On Ind. Electron., Vol. 4, pp.321-328, 1997.
  5. G. Garcera, M. Pascual, and E. Figueres, "A new current controller applied to four-branch inverter shunt active filters with UPF control method," IEEE 32nd Ann. Power Electron. Specialists Conf., Vol.3, pp.1402-1407, 2001.
  6. L.W. Dixon, J.J. Garcia and L. Moran: "Control system for three-phase active power filter which simultaneously compensates power factor and unbalanced loads," APEC'03 18th Ann., Vol. 1, pp. 141-147, 2003.
  7. N. Geddada, S.B. Karanki, M.K. Mishra and B.K. Kumar: "Modified four leg DSTATCOM topology for compensation of unbalanced and nonlinearloads in three phase four wire system," Proc. of EPE'11, pp. 1- 10, 2011.
  8. L.N Arruda, S.M. Silva, and B.J.C Filho, "PLL structure for utility connected systems," Conf. Rec. of the 36th IEEE-IAS Ann. Meeting, Chicago, USA, pp. 2655-2660, 2001.

피인용 문헌

  1. Novel Simple Reactive Power Control Strategy With DC Capacitor Voltage Control for Active Load Balancer in Three-Phase Four-Wire Distribution Systems vol.51, pp.5, 2015, https://doi.org/10.1109/TIA.2015.2437972