References
- Adam, S., Gagliardo, P., Smith, D., Ross, D., Gramith, K., Trussell, R. (1998) Monitoring the integrity of reverse osmosis membranes, Desalination, 119, pp. 143-150. https://doi.org/10.1016/S0011-9164(98)00134-9
- Choi, S.H., Yang, J.H., Suh, C.W., Cho, J.W. (2011) Use of fluorescent silica particles for checking the integrity of microfiltration membranes, Journal of Membrane Science, 367, pp. 306-313. https://doi.org/10.1016/j.memsci.2010.11.015
- Farahbakhs, K., and Smith, D.W. (2004) Estimating air diffusion contribution to pressure decay during membrane integrity tests, Journal of Membrane Science, 237, pp. 203-212. https://doi.org/10.1016/j.memsci.2004.03.015
- Giglia, S., and Krishnan, M. (2008) High sensitivity binary gas integrity test for membrane filters, Journal of Membrane Science, 323, pp. 60-66. https://doi.org/10.1016/j.memsci.2008.06.017
- Gil F. Crozes Sandeep Sethi, Baoci Mi, Jason Curl, Benito Marinas, (2002). Improving membrane integrity monitoring indirect methods to reduce plant downtime and increase microbial removal credit, Desalination, 149, pp. 493-497. https://doi.org/10.1016/S0011-9164(02)00787-7
- Glucina, K., Do-Quang, Z., Laine, J.M. (1997) Assessment of a particle counting method for hollow fiber membrane integrity, Desalination, 113, pp. 183-187. https://doi.org/10.1016/S0011-9164(97)00127-6
- Guibert, D., Colling, A. (2011) Direct membrane integrity testing : Impact of parameter selection on log removal value calculations, Desalination, 272, pp. 174-178. https://doi.org/10.1016/j.desal.2011.01.017
- Guo, H., Wyart, Y., Perot, J., Nauleau, F., Moulin, P. (2010) Application of magnetic nanoparticles for UF membrane integrity monitoring at low-pressure operation, Journal of Membrane Science, 350, pp. 172-179. https://doi.org/10.1016/j.memsci.2009.12.025
- Hur, H.C., Rhee, O.J., Lee, K.J., Kim, K.H., Choi, Y.J., Lee, J.J., Hong, S.K. (2008) Analysis of membrane integrity and removal efficiency considering membrane defect and pore size, Journal of Korean Society on Water Quality, 24(4), pp. 423-429.
- Masson, P.L. (1987) Particle counting immunoassay-an overview, Journal of Pharmaceutical & Biomedical Analysis, 5(2), pp. 113-117. https://doi.org/10.1016/0731-7085(87)80013-4
- Miller, C.R., Vogel, R., Surawski, P., Jack, K.S., Corrie, S.R., Trau, M. (2005) Functionalized organosilica microspheres via a novel emulsion-based route, Langmuir, 21, pp. 9733-9740. https://doi.org/10.1021/la0514112
- Nismith, J. (2005) Membrane integrity - direct turbidity measurement of filtrate from MF membrane modules at an operating potable water treatment plant, Desalination, 179, pp. 25-30. https://doi.org/10.1016/j.desal.2004.11.052
- Panglisch, S., Deinert, U., Dautzengerg, W., Keipke, O., Gimbel, R. (1998) Monitoring the integrity of capillary membranes by particle counters, Desalination, 19, pp. 65-72.
- Vogel, R., Surawski, P.P.T., Littleton, B.L., Miller, C.R., Lawrie, G.A., Battersby, B.J., Trau, M. (2007) Fluorescent organosilica micro-and nanoparticles with controllable size, Journal of Colloid and Interface Science, 310, pp. 144-150. https://doi.org/10.1016/j.jcis.2007.01.092