참고문헌
- Douwes J, Thorne P, Pearce N, Heederik D. Bioaerosol health effects and exposure assessment: progress and prospects. Ann Occup Hyg. 2003; 47(3): 187-200. https://doi.org/10.1093/annhyg/meg032
- Kwon SB, Park DS, Cho YM, Park EY. Measurement of natural ventilation ratein Seoul metropolitan subway cabin. Ind Buil Environ. 2010; 19(3):366-374. https://doi.org/10.1177/1420326X10367305
- Saijo Y, Kishi R, Sata F, Katakura Y, Urashima Y, Hatakeyyama A, et al. Symptoms in relation to chemicals and dampness in newly builtdwellings. Int Arch Occup Environ Health. 2004; 77(7): 461-470. https://doi.org/10.1007/s00420-004-0535-0
- Macher JM. Bioaerosols: Assessment and Control. Cincinnati: ACGIH Press; 1999. p.1-322.
- Selim MI, Juchems AM, Popendorf W. Assessing airborne Aflatoxin B1 during on-farm grain handling activities. Am Ind Hyg Assoc J. 1998; 59(4): 252-256. https://doi.org/10.1080/15428119891010514
- Desai MS, Ghosh SK. Aflatoxin related hazards among Rice mill workers. J Toxicol. 1989; 8(1-2): 81-88.
- Hwang SH, Yoo KN, Park DU, Yoon CS. Exposure Level of Airborne Bacteria in the University Laboratories in Seoul, Korea. J Environ Health Sci. 2009; 35(5): 355-361. https://doi.org/10.5668/JEHS.2009.35.5.355
- Hwang SH, Park DU, Ha KC, Park HH, Joo SI, Yoon CS. Concentrations and environmental influences of airborne fungi at university laboratories, hospital diagnostic laboratories. J Kor Soc Occup Environ Hyg. 2010; 20(4): 256-262.
- Park DU, Ryu SH, Kim SB, Byun HJ, Yoon CS, Lee KM. Airborne bacteria and fungi associated with waste-handling work. Int J Occup Environ Hlth. 2013; 19(4): 193-200.
- Cho JH, Paik NW. Assessment of airborne fungi concentrations in subway stations in Seoul, Korea. J Environ Health Sci. 2009; 35(6): 487-494. https://doi.org/10.5668/JEHS.2009.35.6.478
- Kim KY, Kim YS, Kim DK, Kim HT. Exposure level and distribution characteristics of airborne bacteria and fungi in Seoul Metropolitan subway stations. Ind Health. 2011; 49(2): 242-248. https://doi.org/10.2486/indhealth.MS1199
- Indoor Air Quality Association(IAQA). Indoor Air Quality Standard 95-1 Recommended for Florida. Longwood: IAQA Press; 1995.
- OSHA. OSHA Technical Manual. Available: http://www.osha.gov/dts/osta/otm/otm_iii/otm_2.html [accessed 5 March 2014].
- Boudia N, Halley R, Kennedy G, Lambert J, Gareau L, Zayed J. Managanese concentrations in the air of the Montreal(Canada) subway in relation to surface automobile traffic density. Sci Total Environ. 2006; 366(1): 143-147. https://doi.org/10.1016/j.scitotenv.2005.09.094
- Hwang SH, Yoon CS, Ryu KN, Paik SY, Cho JH. Assessment of airborne environmental bacteria and related factors in 25 underground railway staions in Seoul, Korea. Atmos Environ. 2010; 44(13): 1658-1662. https://doi.org/10.1016/j.atmosenv.2010.01.047