DOI QR코드

DOI QR Code

관성측정장치를 이용한 요추 가동범위 측정방법의 반복성 및 검사자 내 검사-재검사 신뢰도 연구

Test-retest Reliability and Intratest Repeatability of Measuring Lumbar Range of Motion Using Inertial Measurement Unit

  • 안지훈 (대전자생한방병원 침구의학과) ;
  • 김현호 (경희대학교 한의과대학 진단.생기능의학과) ;
  • 윤우석 (경희대학교 한의과대학 한방인체정보의학과) ;
  • 이순호 (대전자생한방병원 침구의학과) ;
  • 신유빈 (대전자생한방병원 침구의학과) ;
  • 김상민 (대전자생한방병원 침구의학과) ;
  • 박영재 (경희대학교 한의과대학 진단.생기능의학과) ;
  • 박영배 (경희대학교 한의과대학 진단.생기능의학과)
  • Ahn, Ji Hoon (Department of Acupuncture and Moxibustion Medicine, DaeJeon Jaseng Hospital of Oriental Medicine) ;
  • Kim, Hyun Ho (Department of Biofunctional Medicine and Diagnostics, College of Korean Medicine, Kyung Hee University) ;
  • Youn, Woo Suck (Department of Human Informatics of Korean Medicine, Interdisciplinary Programs, Kyung Hee University) ;
  • Lee, Sun Ho (Department of Acupuncture and Moxibustion Medicine, DaeJeon Jaseng Hospital of Oriental Medicine) ;
  • Shin, You Bin (Department of Acupuncture and Moxibustion Medicine, DaeJeon Jaseng Hospital of Oriental Medicine) ;
  • Kim, Sang Min (Department of Acupuncture and Moxibustion Medicine, DaeJeon Jaseng Hospital of Oriental Medicine) ;
  • Park, Young Jae (Department of Biofunctional Medicine and Diagnostics, College of Korean Medicine, Kyung Hee University) ;
  • Park, Young Bae (Department of Biofunctional Medicine and Diagnostics, College of Korean Medicine, Kyung Hee University)
  • 투고 : 2014.02.10
  • 심사 : 2014.03.10
  • 발행 : 2014.03.20

초록

Objectives : The purpose of this study is to estimate the test-retest reliability and the intratest repeatability in measuring the lumbar range of motion of healthy volunteers with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the lumbar spine movement. Methods : 19 healthy male volunteers were participated, who got under 21 points at oswestry disability index(ODI) were adopted. Their lumbar motion were measured with IMU twice in consecutive an hour for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Lumbar range of motion of flexion $41.45^{\circ}$, extension $16.34^{\circ}$, right lateral bending $16.41^{\circ}$ left lateral bending $13.63^{\circ}$ right rotation $-2.47^{\circ}$, left rotation $-0.61^{\circ}$. ICCs were 0.96~1.00(intratest repeatability) and 0.61~0.92(test-retest reliability). Conclusion : This study shows that MEMS-IMU system demonstrates a high test-retest reliability and intratest repeatability by calculated intraclass correlation coefficients. The results of this study represents that wireless inertial sensor measurement system has portable and economical efficiency. By MEMS-IMU system, we can measures lumbar range of motion and analyze lumbar motion effectively.

키워드

참고문헌

  1. Neuman DA. Kinesiology of the musculoskeletal system. Seoul : Jungdam media. 2010 : 3-26.
  2. Kim H, Shin SH, Kim JK, Park YJ, Oh HS, Park YB. Cervical coupling motion characteristics in healthy people using a wireless inertial measurement unit. Evidence-based Complementary and Alternative Medicine. 2013 ; art. no. 570428.
  3. Klein AB, Snyder-Mackler L, Roy SH, DeLuca CJ. Comparison of spinal mobility and isometric trunk extensor forces with electromyographic spectral analysis in identifying low back pain. Phys Ther. 1991 ; 71 : 445-54.
  4. Mayer TG, Tencer AF, Kristoferson S, Mooney V. Use of noninvasive techniques for quantification of spinal range-of-motion in normal subjects and chronic low back dysfunction patients. Spine. 1984 ; 9(6) : 588-95. https://doi.org/10.1097/00007632-198409000-00009
  5. Hunt DG, Zuberbier OA, Kozlowski AJ et al. Reliability of the lumbar flexion, lumbar extension, and passive straight leg raise test in normal populations embedded within a complete physical examination. Spine. 2001 ; 26(24) : 2714-8. https://doi.org/10.1097/00007632-200112150-00018
  6. White AA, 3rd, Panjabi MM. The basic kinematics of the human spine: A review of past and current knowledge. Spine. 1978 ; 3(1) : 12-20. https://doi.org/10.1097/00007632-197803000-00003
  7. Panjabi MM, Oxland TR, Yamamoto I et al. Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves. J Bone Joint Surg Am. 1994 ; 76A : 413-24.
  8. Barthes X, Walter B, Zeller R et al. Biomechanical behaviour in vitro of the spine and lumbosacral junction. Surg Radiol Anat. 1999 ; 21(6) : 377-81. https://doi.org/10.1007/BF01631345
  9. Tojima M, Ogata N, Yozu A, Sumitani M, Haga N. Novel 3-dimensional motion analysis method for measuring the lumbar spine range of motion. Spine. 2013 ; 38(21) : E1327-33. https://doi.org/10.1097/BRS.0b013e3182a0dbc5
  10. Hindle RJ, Pearcy MJ, Cross AT et al. Three-dimensional kinematics of the human back. Clin Biomech. 1990 ; 5(4) : 218-28. https://doi.org/10.1016/0268-0033(90)90005-Q
  11. Al-Eisa E, Egan D, Deluzio K, Wassersug R. Effects of pelvic skeletal asymmetry on trunk movement: Three-dimensional analysis in healthy individuals versus patients with mechanical low back pain. Spine. 2006 ; 31(3) : E71-9. https://doi.org/10.1097/01.brs.0000197665.93559.04
  12. Jeong WH, Jee HM, Park JH. Real-time 3-Dimensional Measurement of Lumbar Spine Range of Motion using a Wireless Sensor. Journal of Institute of Control, Robotics and Systems. Journal of Control, Automation, and Systems Engineering. 2012 ; 18(8) : 713-8.
  13. Ha TH, Saber-Sheikh K, Moore AP, Jones MP. Measurement of lumbar spinal posture and motion using inertial sensors-A protocol validity study. Manual Therapy. 2013 ; 18(1) : 87-91. https://doi.org/10.1016/j.math.2012.04.003
  14. Kim HH, Kim KW, Park JM et al. Test-retest Reliability and Intratest Repeatability of Measuring Cervical Range of Motion Using Inertial Measurement Unit. The Acupuncture. 2013 ; 30(4) : 25-33.
  15. Fairbank JC, Couper J, Davies JB et al. The Oswestry low back pain disability questionnaire. Physiotherapy. 1980 ; 66(8) : 271-3.
  16. Kim DY, Lee SH, Lee HY et al. Validation of the Korean Version of the Oswestry Disability Index. Spine. 2005 ; 30(5) : E123-7. https://doi.org/10.1097/01.brs.0000157172.00635.3a
  17. Pinsault N, Vuillerme N. Test-retest reliability of centre of foot pressure measures to assess postural control during unperturbed stance. Med Eng Phys. 2009 ; 31(2) : 276-86. https://doi.org/10.1016/j.medengphy.2008.08.003
  18. Schuit D, Petersen C, Johnson R, Levine P, Knecht H, Goldberg D. Validity and reliability of measures obtained from the OSI CA-6000 Spine Motion Analyzer for lumbar spinal motion. Manual Therapy. 1997 ; 2(4) : 206-15. https://doi.org/10.1054/math.1997.0301
  19. Dvořak J, Vajda EG, Grob D, Panjabi MM. Normal motion of the lumbar spine as related to age and gender. European Spine Journal. 1995 ; 4(1) : 18-23. https://doi.org/10.1007/BF00298413
  20. Kendall FP, Kendall EM, Provance PG. Muscles: testing and function with posture and pain. Seoul : Pureunsol. 2001 : 81-9.
  21. Marras WS, Lavender SA, Leurgans SE et al. The role of dynamic three dimensional trunk motion in occupationally related low back disorders: the effects of workplace factors, trunk position, and trunk motion characteristics on risk injury. Spine. 1993 ; 18(5) : 617-28. https://doi.org/10.1097/00007632-199304000-00015

피인용 문헌

  1. 앉은 자세에서 방석센서를 이용한 요통환자 골반가동성 측정의 신뢰도와 타당도 vol.15, pp.2, 2014, https://doi.org/10.13066/kspm.2020.15.2.83