DOI QR코드

DOI QR Code

적층 벤더형 압전식 공압밸브의 내구 특성

Endurance of Pneumatic Valve with a Multi-bender PZT Actuator

  • 윤소남 (한국기계연구원 극한에너지기계열구실) ;
  • 박인섭 (한국기계연구원 열공정극한기술연구실)
  • Yun, So-Nam (Department of Extreme Energy Systems, Korea Institute of Machinery & Materials) ;
  • Park, In-Sub (Department of advanced thermal system, Korea Institute of Machinery & Materials)
  • 투고 : 2012.12.26
  • 심사 : 2014.03.04
  • 발행 : 2014.04.30

초록

In this paper, pneumatic valve which consists of valve body, valve controller, nozzle and a multi-bender PZT actuator was suggested and fabricated. The fabricated pneumatic valve was experimented for performance evaluation. From the experimental results, we know that the flow rate of the suggested valve is 23 lpm at the pressure difference of 1bar and the maximum flow rate is 30 lpm at the pressure difference of 4 bar. The flow rates after endurance test of 9.8 million were 22.57 lpm and 28.62 lpm at the pressure difference of 1bar and 4bar, respectably. Finally, it was verified that the B10 life of the suggested pneumatic valve is over 50 million.

키워드

참고문헌

  1. M. Weinmann, P. Post, H. Vollmer and S. Kluge, 2000, "Pneumatic silicon microvalves with piezoelectric actuation", Actuator 2000, pp. B1.4.
  2. Ki Hara, 2006, "Development of high pressure control relief valve", 2006 JFPS Autumn Conference, pp. 73-75.
  3. Ouchi, 2006, "Step motion mechanism driven by impulsive force of a multi-layer PZT actuator", 2006 JFPS Autumn Conference, pp. 46-48.
  4. Karl Spanner, 2000, "Breakthrough in Piezo actuator applications", Actuator 2000, pp. B2.0.
  5. S. C. Hwang and S. U. Kim, 2001, "Piezoelectric actuator for precision displacement control", RIST research thesis, Vol. 15, No. 2, pp. 158-162
  6. F. Boeking and B. sugg, 2006, "Piezo actuators: a technology prevails with injection valves for combustion engines", Actuator 2006, pp. A5.0.
  7. M. Weinmann, M. Mailchl and G. Munz, 2002, "A 3/2 normally closed polymer piezoelectric microvalve with integrated mid electronics for industrial automation", Actuator 2002, pp. 533-536.
  8. M. Weinmann, M. Muth, M. Giousouf and C. Hanisch, 2002, "State of the art in pneumatic microvalves", Actuator 2002, pp. 217-222.
  9. S. N. Yun, Y. B. Ham, C. Y. Kim, P. W. Park and J. H. Kang, 2005, "Characteristics improvement of a PZT actuator for metal printing", Jounal of the Korean Society for Power System Engineering", Vol. 9, No. 4, pp. 162-167.

피인용 문헌

  1. Performance Analysis of Air Operated Valve by Thermal Aging vol.19, pp.5, 2015, https://doi.org/10.9726/kspse.2015.19.5.093