DOI QR코드

DOI QR Code

Fundamental Evaluation and Hydration Heat Analysis of Low Heat Concrete with Premixed Cement

저발열형 Premixed Cement를 사용한 콘크리트의 기초물성 평가 및 수화열 해석에 관한 연구

  • Received : 2014.02.11
  • Accepted : 2014.03.24
  • Published : 2014.03.30

Abstract

This study carried out to evaluate the hydration heat analysis and fundamental characteristics such as air content, slump, compressive strength and dry shrinkage according to concrete with premixed cement, ternary concrete and OPC concrete for using concrete with premixed cement. The results of experiment are founded that concrete with premixed cement have sufficient performances such as workability, compressive strength and dry shrinkage. Also, the results of hydration heat analysis are founded that concrete with premixed cement have more performance than ternary concrete and OPC concrete at a point of view for the quality control such as thermal crack reducing and economic benefit. Therefore, it is desirable that concrete with premixed cement should be used to rise durability performance and convenience of maintenance.

본 연구에서는 시멘트와 광물질혼화재인 고로슬래그미분말과 플라이애쉬를 미리 혼입한 Premixed Cement를 사용한 콘크리트와 수축저감제가 혼입된 3성분계 콘크리트, OPC 100%의 콘크리트에 대하여 기초물성 평가로 공기량, 슬럼프, 압축강도 및 건조수축 시험을 수행하고, 수화열 해석을 수행하여 Premixed Cement를 사용한 콘크리트의 현장 적용성을 검토하였다. 검토결과 Premixed Cement를 사용한 콘크리트는 목표 작업성 및 설계기준압축강도를 충분히 만족하며, 건조수축 측면에서도 수축 저감제를 혼입한 3성분계 콘크리트와 유사한 건조수축 특성을 나타내었다. 또한, 수화열 해석 결과 Premixed Cement를 사용한 콘크리트는 목표 온도균열지수를 충분히 확보할 뿐만 아니라, 수축 저감제를 혼입한 3성분계 콘크리트보다 경제성을 확보할 수 있는 방안으로 도출되었다. 향후 매스콘크리트구조물 시공에 있어 구조물의 내구성능 및 유지관리 편의성 향상을 위해 Premixed Cement를 사용한 콘크리트의 현장적용은 바람직한 것으로 판단된다.

Keywords

References

  1. Bae, J.Y., Kim, J.B., Cho, S.H., Roh, H.S., Kim, J.H., and Park, S.B. (2008). An experimental study on the quality deviation of concrete using premixed cement and non-premixed cement. Conference paper on Korea Concrete Institute, 569-572.
  2. Choi, H., Lee, S.S., Won, C., Kim, D.S., and Jung, H.W. (2000). A study on economical impact and properties of concrete using blast-furnace slag powder. Daewoo E&C, 22, 61-73.
  3. Choi, H.K., Son, H.J., Kim, K.M., Park, S.J., Han, M.C., and Han, C.G. (2011). Properties of low heat concrete using modified ternary blended cement. Conference paper on Korean Recycled Construction Resources Institute, 11(1), 77-78.
  4. Jeon, C.K. and Jeon, J.K. (2013). A experimental study on the field application of concrete with $CO_2$ reduction materials. Journal of the Korean Society of Disaster Information, 9(2), 128-136.
  5. Jeon, J.K. and Yoon, J.H. (2013). A case study analysis for enhancing application of slag in concrete. Journal of Korean Recycled Construction Resources Institute, 8(1), 11-14.
  6. Kim, G.Y., Shin, K.S., Lim, C.H., Nam, J.S., and Kim, M.H. (2010). Properties of engineering and durability concrete with fly-ash and blast furnace slag in normal strength level. Journal of Korean Recycled Construction Resources Institute, 5(1), 103-110.
  7. Kim, J.H. and Lee, K.I. (2008). Necessity of blended cement. Journal of Korea Concrete Institute, 20(3), 10-12.
  8. Korea Concrete Institute. (2007). Standard specification for concrete.
  9. Korea Iron and Steel Association. (2012). Concrete & slag green solution.
  10. Lee, S.S. and Song, H.Y. (2007). An experimental study on the durability and mechanical properties of high performance concrete using blast-furnace slag powder. Journal of Architectural Institute of Korea, 23(11), 119-126.
  11. Ssangyong Technology Research Center. (2005). Causes and Preventions of Cracks in Concrete.
  12. Yoon, J.H., Jeon, J.K., Jeon, C.K., Ryou, J.S., and Kim, K.H. (2013). Fundamental evaluation and field application of slag concrete. Conference paper on Korean Recycled Construction Resources Institute, 13(1), 5-6.
  13. Yoon, J.H., Jeon, J.K., Jeon, C.K., Yoon, K.H., and Lee, S.C. (2013). Hydration heat analysis and field appliction of mass concrete using ternary blended cement. Conference paper on Korean Recycled Construction Resources Institute, 13(2), 43-44.
  14. Yoon, S., Song, Y.W., Jeong, Y., Gong, M.H., and Chung, G.T. (2013). Investigation on the properties of concrete using ternary blended cement. Conference paper on Korea Concrete Institute, 165-166.

Cited by

  1. Study on Hydration Heat Analysis of Pier Foundation-Column Using Low Heat Concrete vol.2, pp.3, 2014, https://doi.org/10.14190/JRCR.2014.2.3.217