Corrugated steel plate structure, which is built by assembling corrugated steel plate segments with bolts on site and filling the surroundings with quality soil, is widely used for buried structures as a eco-corridors, small bridges, and closed conduits. This experimental study is dealt with the static and fatigue performance of bolt connected corrugated steel plates under flexural loading. The experimental variables to verify the fatigue performance are bolt diameters and detailing of connection such as washer and the corrugation dimension of specimens has a $400{\times}150$ mm. The experimental ultimate strength of specimens under static loading was higher than the theoretical strength and all specimen failed by a bearing and tearing failure of bolt hole of upper plate. Therefore, a fatigue tests of specimens had 6.0mm and 7.0mm thickness was conducted in which the load range was up to 209kN and 516kN, respectively. From the fatigue test, failure patterns are changed from plate bearing and tearing which is a typical failure pattern of static failure to a bearing failure of plate and shear failure of bolt, and experimental fatigue limit at $2{\times}10^6$cycles is about 85MPa.

파형강판 구조물은 강판 세그먼트를 현장에서 볼트연결하고, 양질의 뒷채움 시공을 통해 시공성을 높일 수 있기 때문에 최근 생태통로, 소규모 교량 및 관로 등에 폭넓게 시공되고 있다. 본 연구는 휨하중을 받는 볼트연결된 파형강판 세스먼트의 정적 및 피로거동을 실험적으로 분석하였다. 피로거동을 분석하기 위하여 볼트 직경, 와셔와 같은 연결부 상세를 실험변수로 하였으며, 실험에 사용된 실험체의 파형의 제원은 $400{\times}150$ mm이다. 정적실험 결과 모든 실험체의 실험 극한강도가 이론강도보다 높게 나타났으며, 강판의 지압 및 상부강판 볼트구멍의 찢김에 의해 파괴되었다. 6mm와 7mm 강판에 대하여 하중범위 209kN에서 517kN사이로 피로실험을 수행하였으며, 실험결과 정적 파괴시의 강판지압과 찢김파괴에서 피로실험시에는 강판지압과 볼트 전단의 형태로 변화하였으며, 2백만회 피로한계는 대략 85MPa로 분석되었다.

Keywords

References

  1. AASHTO (2002), Standard Specifications for Highway Bridges, 17th Edition, American Association of State Highway and Transportation Officials.
  2. Abdel-Sayed, G., Bakht, B., and Leslie, G. J. (1993), Soil-Steel Bridge, McGraw-Hill, New York N.Y.
  3. AMER, H. H. W. (2012), Soil Steel Composite BridgesA comparison between the Pettersson-Sundquist design method and the Kloppel & Glock design method including finite element modelling, Master of Science Thesis, Royal Institute of Technology, 135.
  4. American Iron and Steel Institute (2002), Handbook of steel drainage & Highway construction, AISI, 476.
  5. ASTM A 761 (2003), Standard Specification for Corrugated Steel Structural Plate, Zinc-Coated, for Field-Bolted Pipe, Pipe-Arches, and Arches, ASTM, 8.
  6. ASTM A 796 (2001), Standard Practice for Structural Design of Corrugated Steel Pipe, Pipe-Arches, and Arches for Storm and Sanitary Sewers and Other Buried Applications, ASTM, 15.
  7. Duncan, J. M. (1979), Behaviour and Design of Long-Span Metal Culvert Structures, ASCE Journal of Geotechnical Division, 105(GT3), 399-417.
  8. Mohammed, H., and Kennedy John, B. (2009), Fatigue Resistance of Corrugated Steel Sheets Bolted Lap Joints under Flexture, Practice Periodical on Structural Design and Construction, ASCE, 242-245.
  9. National Standard of Canada (2006), CSA Special Publication Commentary on CNS/CSA-S6-06.
  10. National Standard of Canada CNS/CSA-S6-06 (2006), Canadian Highway Bridge Design Code.
  11. Oh, H., Nam, K. (2012), Verification on the Compressive Behavior of Corrugated Steel Plates due to Details of Bolted Lap Joint, Journal of KSMI, 16(1), 9-17. https://doi.org/10.11112/jksmi.2012.16.1.009
  12. White, H. L., and Layer, J. P. (1960), The Corrugated Metal Conduit as a Compression Ring, Proceedings, Transportation Research Board, USA, 39.

Cited by

  1. The Evaluation of Structural Stability of Corrugated Steel Plate Method applied in High-Speed Railway Vertical Tunnel Structures vol.31, pp.2, 2016, https://doi.org/10.14346/JKOSOS.2016.31.2.64