An Establishment of Commercial Grade Item Dedication Implementing System for Operating NPPs in Korea

가동중원전의 일반규격품 품질검증 이행 체계 구축 방안

  • Received : 2014.03.26
  • Accepted : 2014.06.11
  • Published : 2014.06.30

Abstract

A Commercial Grade Item Dedication(CGID) for Korean operating nuclear power plants has been implemented since 2012. The CGID implementation and strategies for Korea are established as follows: CGID policy establishment, R&D of a specific methodologies of CGID, enrollment of third party organizations for CGID work, CGID program establishment for enrolled suppliers, establishment of training courses for certification, and CGID process development for quality class Q and A. Consequently, it is expected that these activities are enable to enhance the reliability and the safety of components and/or parts in nuclear power plants.

국내 가동중원전은 2012년 이후 일반규격품 품질검증 이행 체계 구축을 위해 정책 수립 및 기술 개발, 일반규격품 품질검증 전문기관 양성, 국내 원전 공급사들의 일반규격품 품질검증프로그램 보유 추진 및 원자력 산업계의 전문인력 양성 등을 적극 추진 중에 있다. 아울러 미국 전력연구소(EPRI)의 관련 기술기준을 기반으로 일반규격품 품질검증프로그램 도입 초기에 개발된 안전성(Q) 등급 품목 품질검증 프로세스를 개선하였고, 국내 원전 고유의 원자력 품질등급 체계인 안전성영향(A) 등급 품목을 위해 안전성등급 품목과 차별화시킨 별도의 검증 프로세스를 개발하였다. 결과적으로, 위와 같은 노력을 통해 국내 가동중원전의 일반규격품 품질검증 이행 체계가 구축될 경우, 원전에서 사용하는 기자재의 신뢰성 및 안전성이 향상될 것으로 기대된다.

Keywords

References

  1. Electric Power Research Institute (EPRI), "Guideline for the Utilization of Commercial Grade Items in Nuclear Safety Related Applications (NP-5652)", June 1988, 1-117
  2. Electric Power Research Institute (EPRI), "Guideline for the Technical Evaluation of Replacement Items in Nuclear Power Plants (NP-6406)", December 1989, 1-123
  3. Electric Power Research Institute (EPRI), "Supplemental Guidance for the Application of EPRI Report NP-5652 on the Utilization of Commercial Grade Items (TR-102260)", March 1994, 1-143
  4. US Nuclear Regulatory Commission (NRC), "Reporting of Defects and Noncompliance (10CFR21)", 369-376
  5. US Nuclear Regulatory Commission (NRC), "License Commercial Grade Procurement and Dedication Programs (GL 91-05)", April, 1991, 5-7
  6. 한국원자력안전기술원 (KINS), "안전성관련품목 대체사용을 위한 일반규격품의 품질검증 (KINS/RG-N17.12)" 2005, 1-7
  7. 김정운, 염동운, 장희승, "일반규격품의 안전성 영향등급 사용을 위한 검증 방안", 한국압력기기공학회, 2013.11, 1-2