Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

  • Sim, Sook Young (Department of Neurosurgery, Inje University Seoul Paik Hospital) ;
  • Choi, Chi Hoon (Department of Radiology, National Medical Center)
  • Received : 2014.05.13
  • Accepted : 2014.08.13
  • Published : 2014.11.28

Abstract

Objective : Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. Methods : Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the angle and number of streak artifacts in axial images, and the maximal diameter of artifacts in three-dimensional (3-D) volume-rendered images. The correlation coefficient (CC) was determined between each clip artifact type and the clip blade length and clip orientation to the CT scan (angle a, lateral clip inclination in axial images; angle b, clip gradient to scan plane in lateral scout images). Results : Angle b correlated negatively with white artifacts (r=-0.589, p<0.001) and positively with the angle (r=0.636, p<0.001) and number (r=0.505, p<0.001) of streak artifacts. Artifacts in 3-D images correlated with clip blade length (r=0.454, p=0.004). Multiple linear regression analysis revealed that angle b was the major parameter influencing white artifacts and the angle and number of streak artifacts in axial images (p<0.001), whereas clip blade length was a major factor in 3-D images (p=0.034). Conclusion : Use of a clip orientation perpendicular to the scan gantry angle decreased the amount of white artifacts and allowed better visualization of the clip site.

Keywords

References

  1. Brown JH, Lustrin ES, Lev MH, Ogilvy CS, Taveras JM : Reduction of aneurysm clip artifacts on CT angiograms : a technical note. AJNR Am J Neuroradiol 20 : 694-696, 1999
  2. Dandy WE : Intracranial aneurysm of the internal carotid artery : cured by operation. Ann Surg 107 : 654-659, 1938 https://doi.org/10.1097/00000658-193805000-00003
  3. Kato Y, Sano H, Katada K, Ogura Y, Ninomiya T, Okuma I, et al. : Effects of new titanium cerebral aneurysm clips on MRI and CT images. Minim Invasive Neurosurg 39 : 82-85, 1996 https://doi.org/10.1055/s-2008-1052223
  4. Klingebiel R, Busch M, Bohner G, Zimmer C, Hoffmann O, Masuhr F : Multi-slice CT angiography in the evaluation of patients with acute cerebrovascular disease--a promising new diagnostic tool. J Neurol 249 : 43-49, 2002 https://doi.org/10.1007/PL00007846
  5. Kovacs A, Flacke S, Tschampa H, Hadizadeh D, Greschus S, Clusmann H, et al. : Gated multidetector computed tomography. A technique to reduce intracranial aneurysm clip and coil artifacts. Clin Neuroradiol 20 : 99-107, 2010 https://doi.org/10.1007/s00062-010-0001-1
  6. Mamourian AC, Erkmen K, Pluta DJ : Nonhelical acquisition CT angiogram after aneurysmal clipping : in vitro testing shows diminished artifact. AJNR Am J Neuroradiol 29 : 660-662, 2008 https://doi.org/10.3174/ajnr.A0893
  7. Mamourian AC, Pluta DJ, Eskey CJ, Merlis AL : Optimizing computed tomography to reduce artifacts from titanium aneurysm clips : an in vitro study. Technical note. J Neurosurg 107 : 1238-1243, 2007 https://doi.org/10.3171/JNS-07/12/1238
  8. Nagatani T, Shibuya M, Ooka K, Suzuki Y, Takayasu M, Yoshida J : Titanium aneurysm clips : mechanical characteristics and clinical trial. Neurol Med Chir (Tokyo) 38 Suppl : 39-44, 1998 https://doi.org/10.2176/nmc.38.suppl_39
  9. Otawara Y, Ogasawara K, Ogawa A, Sasaki M, Takahashi K : Evaluation of vasospasm after subarachnoid hemorrhage by use of multislice computed tomographic angiography. Neurosurgery 51 : 939-942; discussion 942-943, 2002
  10. Pechlivanis I, Konig M, Engelhardt M, Scholz M, Heuser L, Harders A, et al. : Evaluation of clip artefacts in three-dimensional computed tomography. Cent Eur Neurosurg 70 : 9-14, 2009 https://doi.org/10.1055/s-0028-1082055
  11. Sagara Y, Kiyosue H, Hori Y, Sainoo M, Nagatomi H, Mori H : Limitations of three-dimensional reconstructed computerized tomography angiography after clip placement for intracranial aneurysms. J Neurosurg 103 : 656-661, 2005 https://doi.org/10.3171/jns.2005.103.4.0656
  12. van der Schaaf I, van Leeuwen M, Vlassenbroek A, Velthuis B : Minimizing clip artifacts in multi CT angiography of clipped patients. AJNR Am J Neuroradiol 27 : 60-66, 2006
  13. Vannier MW, Hildebolt CF, Conover G, Knapp RH, Yokoyama-Crothers N, Wang G : Three-dimensional dental imaging by spiral CT. A progress report. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 84 : 561-570, 1997 https://doi.org/10.1016/S1079-2104(97)90274-2
  14. von Holst H, Bergstrom M, Möller A, Steiner L, Ribbe T : Titanium clips in neurosurgery for elimination of artefacts in computer tomography (CT) a technical note. Acta Neurochir (Wien) 38 : 101-109, 1977 https://doi.org/10.1007/BF01401546
  15. Watanabe Y, Kashiwagi N, Yamada N, Higashi M, Fukuda T, Morikawa S, et al. : Subtraction 3D CT angiography with the orbital synchronized helical scan technique for the evaluation of postoperative cerebral aneurysms treated with cobalt-alloy clips. AJNR Am J Neuroradiol 29 : 1071-1075, 2008 https://doi.org/10.3174/ajnr.A1040
  16. Zachenhofer I, Cejna M, Schuster A, Donat M, Roessler K : Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology : a retrospective study and review of the literature. Clin Neurol Neurosurg 112 : 386-391, 2010 https://doi.org/10.1016/j.clineuro.2010.02.001