DOI QR코드

DOI QR Code

Validity Review on Classification of Explosion Hazardous Area using Hypothetic Volume

가상체적을 이용한 폭발위험장소 구분의 타당성 검토

  • Yim, Ji-Pyo (Korea Occupational Safety & Health Agency) ;
  • Chung, Chang-Bock (School of Applied Chemical Engineering, Chonnam National University)
  • 임지표 (한국산업안전보건공단) ;
  • 정창복 (전남대학교 응용화학공학부)
  • Received : 2014.08.20
  • Accepted : 2014.10.24
  • Published : 2014.12.31

Abstract

It is very important to classify explosion hazardous area (EHA) suitably and to use proper explosion-proof electric installations for facilities using flammable gases and liquids. In the past, various examples in the Notification of Ministry of Employment and Labor were referred to in classifying EHA. But, at present, many companies use the hypothetical volume in Korean Standards (KS). This study reviews the validity of EHA classification based on the hypothetical volume by comparing the calculated radii of EHA with those obtained by a consequence analysis program called PHAST and a mathematical approach in British Standards (BS). The radii of EHA by the hypothetical volume were found to be slightly larger than those by the other two methods. This was attributed to rather conservative uses of a safety factor(k) and a correction factor(f) for availability of ventilation in calculating the hypothetical volume. Since the differences are not so conspicuous, however, it is concluded that the hypothetical volume in KS is a valid means for the classification of EHA. This study also presents a table of the radii of EHA for easy reference by small-scale companies using city gas, C3-LPG and flammable liquid(toluene), respectively. The table consists of 25 leakage scenarios corresponding to combinations of 5 pipe(nozzle) sizes and 5 operating conditions for each flammable gas and liquid.

Keywords

References

  1. Alan McMillan, "Electrical Installations in Hazardous Areas", Elsevier Science LTD, pp. 87-124, 2012.
  2. API PR 505, "Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2", American Petroleum Institute, pp. 21-43, 1997.
  3. NFPA 497A, "Recommended Practice for Classification of Class I Hazardoud(Classified) Locations for Electrical Installation in Chemical Process Areas", National Fire Protection Association, pp. 4-39, 1992.
  4. KS C IEC 60079-10-1, "Explosive atmospheres - Part 10-1 : Classification of Areas-Explosive Gas Atmospheres", Korean Industrial Standards, pp. 1-34, 2012.
  5. IEC 60079-10-1, "Explosive Atmospheres - Part 10-1 : Classification of Areas-Explosive Gas Atmospheres", International Electrotechnical Commission, pp. 24-39, 2008.
  6. J. -P. Yim and C. -B. Chung, "A Study on Classification of Explosion Hazardous Area for Facilities using Lighterthan- Air Gases", Journal of the Korea Society of Safety, Vol. 29, No. 2, pp. 24-30, 2014. https://doi.org/10.14346/JKOSOS.2014.29.2.024
  7. KOSHA Guide P-92, "Technical Guideline for Source Modelling", Korea Occupational Safety & Health Agency, pp. 4-7. 2012.