References
- H.S. Jeon, "Next generation of PC Wearable device market and technology trend," Weekly Technology Trend (www.nipa.kr), vol. 1635, pp. 14-26, 2014.
- A. Pantelopoulos and N.G. Bourbakis, "A survey on wearable sensor-based systems for health monitoring and prognosis," Systems, Man, and Cybernetics, Part C: Applications and Reviews, IEEE Transactions on, vol. 40, pp. 1-12, 2010.J. https://doi.org/10.1109/TSMCA.2009.2037571
- H.H. Asada, P. Shaltis, A. Reisner, S. Rhee, and R.C. Hutchinson, "Mobile monitoring with wearable photoplethysmographic biosensors," Engineering in Medicine and Biology Magazine, IEEE, vol. 22, pp. 28-40, 2003.
- P.A. Shaltis, A. Reisner, and H.H. Asada, "Wearable, cuff-less PPG-based blood pressure monitor with novel height sensor," Engineering in Medicine and Biology Society, 28th Annual International Conference of the IEEE, pp. 908-911, 2006.
- M. Di Rienzo, F. Rizzo, G. Parati, G. Brambilla, M. Ferratini, and P. Castiglioni, "MagIC system: A new textile-based wearable device for biological signal monitoring. Applicability in daily life and clinical setting," Engineering in Medicine and Biology Society, 27th Annual International Conference of the IEEE, pp. 7167-7169, 2005.
- J.S. Lee, J. Heo, W.K. Lee, Y.G. Lim, Y.H. Kim, and K.S. Park, "Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory Electrocardiogram," Sensors, vol. 14, pp. 14732-14743, 2014. https://doi.org/10.3390/s140814732
- L.B. Wood and H.H. Asada, "Noise cancellation model validation for reduced motion artifact wearable PPG sensors using MEMS accelerometers," Engineering in Medicine and Biology Society, 28th Annual International Conference of the IEEE, pp. 3525-3528, 2006.
- M. Sung, R. DeVaul, S. Jimenez, J. Gips, and A. Pentland, "Shiver motion and core body temperature classification for wearable soldier health monitoring systems," Wearable Computers, Eighth International Symposium on, pp. 192-193, 2004.
- L.F. Wang, J.Q. Liu, Y. Dong, B. Yang, X. Chen, and C.S. Yang, "Polydimethyl- siloxane film for biomimetic dry adhesive integrated with capacitive biopotentials sensing," Sensors and Actuators B: Chemical, 2014.
- T. Reinvuo, M. Hannula, H. Sorvoja, E. Alasaarela, and R. Myllyla, "Measurement of respiratory rate with high-resolution accelerometer and EMFit pressure sensor," Sensors Applications Symposium, Proceedings of the 2006 IEEE, pp. 192-195, 2006.
- E. Sardini and M. Serpelloni, "Instrumented wearable belt for wireless health monitoring," Procedia Engineering, vol. 5, pp. 580-583, 2010. https://doi.org/10.1016/j.proeng.2010.09.176
- D. Wu, L. Wang, Y.-T. Zhang, B.-Y. Huang, B. Wang, S.-J. Lin, et al., "A wearable respiration monitoring system based on digital respiratory inductive plethysmography," Engineering in Medicine and Biology Society, Annual International Conference of the IEEE, pp. 4844-4847, 2009.
- Y.G. Lim, K.K. Kim, and S. Park, "ECG measurement on a chair without conductive contact," Biomedical Engineering, IEEE Transactions on, vol. 53, pp. 956-959, 2006. https://doi.org/10.1109/TBME.2006.872823
- H.J. Baek, G.S. Chung, K.K. Kim, and K.S. Park, "A smart health monitoring chair for nonintrusive measurement of biological signals," Information Technology in Biomedicine, IEEE Transactions on, vol. 16, pp. 150-158, 2012. https://doi.org/10.1109/TITB.2011.2175742
- T. Matsuda and M. Makikawa, "ECG monitoring of a car driver using capacitively-coupled electrodes," Engineering in Medicine and Biology Society, 30th Annual International Conference of the IEEE, pp. 1315-1318, 2008.
- Y.G. Lim, K.K. Kim, and K.S. Park, "ECG recording on a bed during sleep without direct skin-contact," Biomedical Engineering, IEEE Transactions on, vol. 54, pp. 718-725, 2007. https://doi.org/10.1109/TBME.2006.889194
- S.M. Lee, K.S. Sim, K.K. Kim, Y.G. Lim, and K.S. Park, "Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement," Medical & biological engineering & computing, vol. 48, pp. 447-457, 2010. https://doi.org/10.1007/s11517-010-0597-y
- J.W. Jeong, M.K. Kim, H. Cheng, W.H. Yeo, X. Huang, Y. Liu, et al., "Capacitive Epidermal Electronics for Electrically Safe, Long-Term Electrophysiological Measurements," Advanced healthcare materials, vol. 3, pp. 642-648, 2014. https://doi.org/10.1002/adhm.201300334
- W.K. Lee, H.J. Lee, H.N. Yoon, G.S. Chung, and K.S. Park, "Automatic Noise Removal and Peak Detection Algorithm for ECG Measured from Capacitively Coupled Electrodes Included within a Cloth Mattress Pad," J. Biomed. Eng. Res., vol. 35, no. 4, pp.87-94, 2014. https://doi.org/10.9718/JBER.2014.35.4.87
- H.J. Baek, H.J. Lee, Y.G. Lim, and K.S. Park, "Conductive polymer foam surface improves the performance of a capacitive EEG electrode," Biomedical Engineering, IEEE Transactions on, vol. 59, pp. 3422-3431, 2012. https://doi.org/10.1109/TBME.2012.2215032
Cited by
- Quality Level Classification of ECG Measured using Non-Constraint Approach vol.37, pp.5, 2016, https://doi.org/10.9718/JBER.2016.37.5.161