DOI QR코드

DOI QR Code

적외선 체온의 진단 정확도 평가 연구: 체계적 문헌고찰

Reliability and Accuracy of Infrared Temperature: A Systematic Review

  • 투고 : 2014.08.20
  • 심사 : 2014.12.01
  • 발행 : 2014.12.31

초록

Purpose: The aim of this study was to investigate the accuracy of infrared temperature measurements compared to axillary temperature in order to detect fever in patients. Methods: Studies published between 1946 and 2012 from periodicals indexed in Ovid Medline, Embase, CINAHL, Cochrane, KoreaMed, NDSL, KERIS and other databases were selected using the following key words: "infrared thermometer". QUADAS-II was utilized to assess the internal validity of the diagnostic studies. Selected studies were analyzed through a meta-analysis using MetaDisc 1.4. Results: Twenty-one diagnostic studies with high methodological quality were included representing 3,623 subjects in total. Results of the meta-analysis showed that the pooled sensitivity, specificity, and area under the curve (AUC) of infrared tympanic thermometers were 0.73 (95% CI 0.70~0.75), 0.92 (95% CI 0.91~0.92), and 0.90, respectively. For axillary temperature readings, the pooled sensitivity was 0.67 (95% CI 0.62~0.73), the pooled specificity was 0.87 (95% CI 0.85~0.90), and the AUC was 0.80. Conclusion: Infrared tympanic temperature can predict axillary temperature in normothermic and in febrile patients with an acceptable level of diagnostic accuracy. However, further research is necessary to substantiate this finding in patients with hyperthermia.

키워드

참고문헌

  1. Moran JL, Peter JV, Solomon PJ, Grealy B, Smith T, Ashforth W, et al. Tympanic measurements: are they reliable in the critically ill? A clinical study of measures of agreement. Critical Care Medicine. 2007;35(1):155-64. https://doi.org/10.1097/01.CCM.0000250318.31453.CB
  2. Liu CC, Chang RE, Chang WE. Limitations of forehead infrared body temperature detection for fever screening for severe acute respiratory syndrome. Infection Control and Hospital Epidemiology. 2004;25(12):1109-11. https://doi.org/10.1086/502351
  3. Lee TJ, Kim DS. Fever. Korean Journal of Pediatrics. 2007;50: 121-6. https://doi.org/10.3345/kjp.2007.50.2.121
  4. Childs C, Harrison R, Hodkinson C. Tympanic membrane temperature as a measure of core temperature. Archives of Disease in Childhood. 1999;80(3):262-6. http://dx.doi.org/10.1136/adc.80.3.262
  5. Park CW, Park, SN. Development of standard and improvement of reliability in body temperature measurement. Journal of the Korean Society for Precision Engineering. 2007;24(9): 32-6.
  6. Androkites AL, Werger AM, Young ML. Comparison of axillary and infrared tympanic membrane thermometry in a pediatric oncology outpatient setting. Journal of Pediatric Oncology Nursing. 1998;15:216-22. https://doi.org/10.1177/104345429801500404
  7. Yun KW, Lim IS. A study for accuracy and usefulness of tympanic membrane and forehead thermometers. Korean Journal of Pediatrics. 2005;48(8):820-5.
  8. Ministry of Food and Drugs Safety. Medical device regulations revision No. 2014-142. [Internet]. Cheongju: Ministry of Food and Drugs Safety; 2014. [cited 2014 August 11]. Available from: http://www.mfds.go.kr/index.do?x=30&searchkey=title:contents&mid=686&searchword=&division=&y=12&pageNo=6& seq=8211&cmd=v
  9. Macaskill P, Gatsonis C, Deeks J, Harbord R, Takwoingi T. Cochrane handbook for systematic reviews of diagnostic test accuracy version 1.0. [Internet]. The Cochrane Collaboration; 2010 [cited 2013 May 30]. Available from: http://www.cochrane-handbook.org
  10. Moher D, Liberati A, Tetzlaff J, Altman DG, Antes G, Atkins D, et al. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Annals of Internal Medicine. 2009;151(4):264-9. http://dx.doi.org/10.7326/0003-4819-151-4-200908180-00135
  11. Whitting PF, Rutjes AW, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Annals of Internal Medicine. 2011;155(8):529-36. http://dx.doi.org/10.7326/0003-4819-155-8-201110180-00009
  12. Greiner M, Pfeiffer D, Smith RD. Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests. Preventive Veterinary Medicine. 2000;45(1-2): 23-41. http://dx.doi.org/10.1016/S0167-5877(00)00115-X
  13. Walter SD. Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data. Statistics in Medicine. 2002;21(9):1237-56. https://doi.org/10.1002/sim.1099
  14. Higgins JP, Thompson SG. Quantifying heterogeneity in a meta-analysis. Statistics in Medicine. 2002;21(11):1539-58. http://dx.doi.org/10.1002/sim.1186
  15. Fischer JE, Bachmann LM, Jaeschke R. A readers' guide to the interpretation of diagnostic test properties: clinical example of sepsis. Intensive Care Medicine. 2003;29(7):1043-51. https://doi.org/10.1007/s00134-003-1761-8
  16. Zweig MH, Campbell G. Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine. Clinical Chemistry. 1993;39(4):561-77.
  17. Wells N, King J, Hedstrom C, Youngkins J. Does tympanic temperature measure up? The American Journal of Maternal/Child Nursing. 1995;20:95-100. https://doi.org/10.1097/00005721-199503000-00007
  18. Edelu BO, Ojinnaka NC, Ikefuna AN. Fever detection in under 5 children in a tertiary health facility using the infrared tympanic thermometer in the oral mode. Italian Journal of Pediatrics. 2011;37:8. http://dx.doi.org/10.1186/1824-7288-37-8
  19. Dzarr AA, Kamal M, Baba AA. A comparison between infrared tympanic thermometry, oral and axilla with rectal thermometry in neutropenic adults. European Journal of Oncology Nursing. 2009;13(4):250-4. http://dx.doi.org/10.1016/j.ejon.2009.03.006
  20. Smitz S, Van de Winckel A, Smitz MF. Reliability of infrared ear thermometry in the prediction of rectal temperature in older inpatients. Journal of Clinical Nursing 2009;18(3):451-6. http://dx.doi.org/10.1111/j.1365-2702.2008.02565.x
  21. Duberg T, Lundholm C, Holmberg H. Ear thermometer not an adequate alternative to rectal thermometer. Lakartidningen. 2007;104(19):1479-82.
  22. Nordas TG, Leiren S, Hansen KS. Can ear temperature measurement be used in a hospital? Tidsskr Nor Laegeforen. 2005; 125(20):2763-5.
  23. Jean-Mary MB, Dicanzio J, Shaw J, Bernstein HH. Limited accuracy and reliability of infrared axillary and aural thermometers in a pediatric outpatient population. Journal of Pediatrics. 2002;141(5):671-6. https://doi.org/10.1067/mpd.2002.127664
  24. Varney SM, Manthey DE, Culpepper VE, Creedon JFJ. A comparison of oral, tympanic, and rectal temperature measurement in the elderly. Journal of Emergency Medicine. 2002;22(2):153-7. http://dx.doi.org/10.1016/S0736-4679(01)00457-7
  25. Greenes DS, Fleisher GR. Accuracy of a noninvasive temporal artery thermometer for use in infants. Archives of Pediatrics & Adolescent Medicine. 2001;155(3):376-81. https://doi.org/10.1001/archpedi.155.3.376
  26. Smitz S, Giagoultsis T, Dewe W, Albert A. Comparison of rectal and infrared ear temperatures in older hospital inpatients. Journal of American Geriatric Society. 2000;48(1):63-6. https://doi.org/10.1111/j.1532-5415.2000.tb03030.x
  27. Valle PC, Kildahl-Andersen O, Steinvoll K. A comparative study of infrared tympanic thermometry and rectal mercury thermometry. Scandinavian Journal of Infectious Disease. 1999;31(1):105-6. https://doi.org/10.1080/00365549950162014
  28. Lanham DM, Walker B, Klocke E, Jennings M. Accuracy of tympanic temperature readings in children under 6 years of age. Pediatric Nursing. 1999;25(1):39-42.
  29. Wilshaw R, Beckstrand R, Waid D, Schaalje GB. A comparison of the use of tympanic, axillary and rectal thermometers in infants. Journal of Pediatric Nursing. 1999;14(2):88-93. https://doi.org/10.1016/S0882-5963(99)80042-6
  30. Sohng KY, Kang SS, Hwang JS, Kim MJ. Accuracy of temperature measurements, nursing time for measuring temperature and the validity of fever detection. Journal of Korean Academy of Korean Fundamentals of Nursing. 1998;5(1):33-45.
  31. Brennan DF. Falk JL, Rothrock, SG. Kerr RB. Reliability of infrared T thermometry in the detection of R fever in children. Annals of Emergency Medicine. 1995;25(1):21-30. http://dx.doi.org/10.1016/S0196-0644(95)70350-0
  32. Christensen PM, Christensen VB, Matzen LE. Evaluation of ear temperature measurements in a geriatric department. Ugeskr Laeger. 1998;160(36):5175-7.
  33. Hwang JS, Sohng KY. Comparison of rectal temperature with axillary and tympanic temperature. Journal of Korean Academy of Korean Fundamentals of Nursing. 1997;4(2):351-8.
  34. Petersen MH, Hauge HN, Petersen MH, Hauge HN. Can training improve the results with infrared tympanic thermometers? Acta Anaesthesiologica Scandinavica. 1997;41(8):1066-70. https://doi.org/10.1111/j.1399-6576.1997.tb04837.x
  35. Lee WH, Jung SP. The validity of the tympanic membrane thermometer in detecting fever of the children. Journal of the Korean Academy of Family Medicine. 1995;16(8):531-6.
  36. Yaron M, Lowenstein SR, Koziol-McLain J. Measuring the accuracy of the infrared tympanic thermometer: correlation does not signify agreement. The Journal of Emergency Medicine. 1995;13(5):617-21. https://doi.org/10.1016/0736-4679(95)00065-I
  37. Selfridge J, Shea SS. The accuracy of the T membrane thermometer in detecting fever in infants aged 3 months and younger in the emergency department setting. Journal of Emergency Nursing. 1993;19(2):127-30.
  38. Chamberlain JM, Grandner J, Rubinoff JL, Klein BL, Waisman Y, Huey M, et al. Comparison of a tympanic thermometer to rectal and oral thermometers in a pediatric emergency department. Clinical Pediatrics. 1991;30(4 suppl):24-9. https://doi.org/10.1177/000992289103000408

피인용 문헌

  1. 이마 체온의 진단정확도 vol.24, pp.2, 2014, https://doi.org/10.22650/jkcnr.2018.24.2.227
  2. 유헬스케어 패치형 무선 체온 모니터링 시스템 구현 vol.41, pp.1, 2014, https://doi.org/10.9718/jber.2020.41.1.55