DOI QR코드

DOI QR Code

New approach in design of seismic isolated buildings applying clusters of rubber bearings in isolation systems

  • Melkumyan, Mikayel G. (Armenian Association for Earthquake Engineering)
  • Received : 2012.04.04
  • Accepted : 2012.06.08
  • Published : 2013.06.25

Abstract

The given paper presents a new approach in design of seismic isolation systems of base isolated buildings. The idea is to install not one big size rubber bearing under the columns and/or shear walls, or one by one with certain spacing under the load-bearing walls, but to install a group/cluster of small size bearings, in order to increase the overall effectiveness of the isolation system. The advantages of this approach are listed and illustrated by the examples. Also the results of analyses of some buildings where the approach on installation of clusters of rubber bearings was used in their isolation systems are given for two cases: i) when the analyses are carried out based on the provisions of the Armenian Seismic Code, and ii) when the time history analyses are carried out. Obtained results are compared and discussed. Paper also presents, as an example, detailed analysis and design of the 18-story unique building in one of the residential complexes in Yerevan. Earthquake response analyses of this building were carried out in two versions, i.e. when the building is base isolated and when it is fixed base. Several time histories were used in the analyses. Comparison of the obtained results indicates the high effectiveness of the proposed structural concepts of isolation systems and the need for further improvement of the Seismic Code provisions regarding the values of the reduction factors. A separate section in the paper dedicated to the design of high damping laminated rubber-steel bearings and to results of their tests.

Keywords

References

  1. Foti, D and Mongelli, M. (2011), Isolatori sismici per edifice esistenti e di nuova costruzione, Dario Flaccovio Editore, (in Italian).
  2. Fujita, T. (1999), "Demonstration of effectiveness of seismic isolation in the Hanshin-Awaji earthquake and progress of applications of base-isolated buildings", Report on 1995 Kobe Earthquake by INCEDE, ERC and KOBEnet. IIS, University of Tokyo-Voluntary Information Network for Earthquake Disaster Mitigation, Serial No. 15, 197-216.
  3. Fuller, K., Lim, C., Loo, S., Melkumyan, M. and Muniandy, K. (2000), Design and testing of high damping rubber earthquake bearings for retrofit project in Armenia, earthquake hazard and seismic risk reduction, Kluwer Academic Publishers, The Netherlands, 379-385.
  4. Garevski, M. (2010), "Development, production and implementation of low cost rubber bearings, geotechnical, geological and earthquake engineering", 17, Earthq. Eng. in Europe, Springer, 411-437.
  5. Martelli, A. and Forni, M. (2011), "Seismic retrofit of existing buildings by means of seismic isolation: some remarks on the Italian experience and new projects", Proceedings of the 3rd Int. Conference on Computational Methods in Structural Dynam. and Earthq. Eng., COMPDYN 2011, Corfu Island, Greece, 396.
  6. Melkumyan, M. (2004), "Recent applications of seismic isolation in civil buildings in Armenia", Proceedings of the 13th World Conference on Earthq. Eng., Vancouver, British Columbia, Canada, 3318.
  7. Melkumyan, M. (2005), "Current situation in application of seismic isolation technologies in Armenia", Proceedings of the Int. Conference dedicated to the 250th anniversary of the 1755 Lisbon Earthquake, Lisbon, Portugal, 493-500.
  8. Melkumyan, M., Gevorgyan, E. and Hovhannisyan, H. (2005), "Application of base isolation to multifunctional multistory buildings in Yerevan, Armenia", Proceedings of the 9th World Seminar on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures, Kobe, Japan, 2, 119-127.
  9. Melkumyan, M. (2011), "Assessment of the seismic risk in the city of Yerevan and its mitigation by application of innovative seismic isolation technologies", J. Pure Appl. Geophys., 168(3-4), 695-730. https://doi.org/10.1007/s00024-010-0110-4
  10. Melkumyan, M. (2011), New solutions in seismic isolation, LUSABATS, Yerevan.
  11. Moroni, O., Sarrazin, R. and Boroschek, R. (1998), "Experiment on a base-isolated building in Santiago, Chile", J. Eng. Struct., 20(8), 720-725. https://doi.org/10.1016/S0141-0296(97)00086-2
  12. Saito, T. (2006), Observed response of seismically isolated buildings, response control and seismic isolation of buildings, 63-88.
  13. The World Bank Implementation Completion Report (1997), .Armenia earthquake reconstruction project, 17255
  14. Whittaker, D. and Robinson, W. (2009), "Progress of application and R&D for seismic isolation and passive energy dissipation for civil and industrial structures in New Zealand", Proceedings of the 11th World Conference on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures, Guangzhou, China, K04.
  15. Zhou, F., Tan, P., Heisha, W. and Huang, X. (2009), "Recent development and application on seismic isolation in China", Proceedings of the JSSI 15th Anniversary Int. Symposium on Seismic Response Controlled Buildings for Sustainable Society, Tokyo, Japan, OS-2.

Cited by

  1. Theoretical tensile model and cracking performance analysis of laminated rubber bearings under tensile loading vol.52, pp.1, 2014, https://doi.org/10.12989/sem.2014.52.1.075
  2. The effect of base isolation and tuned mass dampers on the seismic response of RC high-rise buildings considering soil-structure interaction vol.17, pp.4, 2013, https://doi.org/10.12989/eas.2019.17.4.425