참고문헌
- Berglundh T, Lindhe J, Dimension of the periimplant mucosa: Biologic width revisited. J Clin Periodontol 1996;23:971-973. https://doi.org/10.1111/j.1600-051X.1996.tb00520.x
- Hermann JS, Buser D, Schenk RK, Cochran DL. Crestal bone changes around titanium implants. A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. J Periodontol 2000;71:1412-1424. https://doi.org/10.1902/jop.2000.71.9.1412
- Hermann JS, Cochran DS, Nummikoski PV, Buser D. Crestal bone changes around titanium implants: A radiographic evaluation of unloaded submerged and nonsubmerged and submerged implants in the canine mandible. J Periodontol 1997;68:1117-1130. https://doi.org/10.1902/jop.1997.68.11.1117
- Hermann JS, Schoolfield JD, Nummikoski PV, Buser D, Schenk RK, Cochran DL. Crestal bone changes around titanium implants. A methodlogical study comparing linear radiographic versus histometric measurements. Int J Oral Maxillofac Implants 2001;16:475-485.
- King GN, Hermann JS, Schoolfield JD, Buser D, Cochran DL. Influence of the size of the microgap on crestal bone levels in non-submerged dental implants: A radiographic study in the canine mandible. J Periodontol 2002;73:1111-1117. https://doi.org/10.1902/jop.2002.73.10.1111
- Geng JP, MA QS, Xu W, Tan KBC, Liu GR. Finite element analysis of thread-form configura-tions in a stepped screw implant. Journal of Oral Rehabilitation 2004;31:233-239. https://doi.org/10.1046/j.0305-182X.2003.01213.x
- Sutpideler M, Eckert SE, Zobitz M, An KN. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone. Int J Oral Maxillofac Implants 2004;19:819-825.
- Chu CM, Huang HL, Hsu JT, Fuh LJ. Influences of internal tapered abutment designs on bone stresses around a dental implant: three-dimensional finite element method with statistical evaluation. J Periodontol 2011;83:111-118.
- Khurana P, Sharma A, Sodhi KK. Influence of fine threads and platform-switching on crestal bone stress around implant-a three dimensional finite element analysis. J Oral Implantol 2011 Sep 9.
- Balik A, Ozdemir Karatas M, Keskin H. Effects of different abutment connection designs on the force distribution around commercially avilable dental implants: A 3-D finite element analysis. J Oral Implantol 2011; Special Issue 1:491-496.
- Lazzara RJ, Porter SS. Platform switching: a new concept in implant dentistry for controlling posterstorative crestal bone levels. Int J Periodontics Restorative Dent 2006;26:9-17.
- Maeda Y, Miura J, Taki I, Sogo, M. Biomechanical analysis on platform switching: is there any biomechanical rationale? Clin Oral Implants Res 2007;18:581-584. https://doi.org/10.1111/j.1600-0501.2007.01398.x
- Pessoa RS, Geraldo Vaz L, Marcantonio E, Sloten JV, Duyck J, Jaecques SVN. Bio mechanical evaluation of platform switching in different implant protocol: Computed Tomography-Based Three-Dimensional Finite Element Analysis. Int J Oral Maxillofac Implants 2010;25:911-919.
- Perssoa RS, Murau L. Marcantonio E Jr, Influence of implant connection type on the biomechanical environment of immediately placed implant: CTbased nonlinear, three dimensional finite element analysis. Clin Implant Dent Relat Res 2010;12:219-234.
- Rieger, MR. Adams, WK Kinzel, GL. Finite element surver of eleven endosseous implants. J Prosthet Dent 1990;63:457-465. https://doi.org/10.1016/0022-3913(90)90238-8
- Merz BR, Hunenbart S, Belser UC. Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000;15:519-526.
- Weinstein AM, Klawitter JJ, Anand SC. Schuessler R. Stress analysis of porous rooted dental implants J Dent Res 1976;55:772-777. https://doi.org/10.1177/00220345760550051001
- Geng JP, Tan KBC, Liu GR. Applications of finite element analysis in implant dentistry, a review of literatures. J Prosthet Dent 2001;85:585-598. https://doi.org/10.1067/mpr.2001.115251
- Chun HJ, Cheong JH, Heo SJ, Chung JP, Rhyu IC, Choi YC, Baik HK, Ku Y, Kim MH. Evaluation of design parameters of osseointegrated dental implants using finite element analysis. Journal of Oral Rehabilitation, 2002;29:565-574. https://doi.org/10.1046/j.1365-2842.2002.00891.x
- Hansson S, Werke M. The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. Journal of Biomechanics 2003;36:1247-1258. https://doi.org/10.1016/S0021-9290(03)00164-7
- Bidez MW, Misch CE. Force transfer in implant dentistry: basic concepts and principles, J Oral Implantol 1992;18:264-274.
- Brunski JB. In vivo bone response to biomechanical loading at the bone/dental-implant interface. Advance Dent Res 1999;13:99-119. https://doi.org/10.1177/08959374990130012301
- Lum LB. A biomechanical rationale for the use of short implants. Journal of Oral implantol 1991;17:126-131.
- Clift SE, Fisher J, Watson CJ. Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus. Proc Inst Mech Eng [H] 1992;206:233-241.
- Mericske-Stern R, Assal P, Mericske E, Burgin W. Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants. Int J Oral Maxillofac Implants 1995;10:345-353.
- Duyck J, Ronald HJ, van Oosterwyck H, Naert I, Vander Sloten J, Ellingsen JE. The influence of static and dynamic loading on marginal bone reaction around osseointegrated implants: an animal experimental study. Clinical Oral Implants research 2001;12:207-218. https://doi.org/10.1034/j.1600-0501.2001.012003207.x
- Quirynen M, Naert I, van Steenberge D. Fixed design and overload influence marginal bone loss and fixture success in the Branemark system. Clin Oral Implants Res 1992;3:103-111.
- Balshi TJ. An analysis and management of fractured implants, A clinical report. Int J Oral Mxillofacial Implants 1996;11:660-666.
- Lobbezoo F, van der Zaag J, Naeije M. Bruxism: its multiple causes and its effects on dental implants -an updated review. J Oral Rehabil 2006;33:293-300. https://doi.org/10.1111/j.1365-2842.2006.01609.x
- Yokoyama S, Wakabayashi N, Shiota M, Ohyama T. The influence of implant location and length on stress distribution for three-unit implant -supported posterior cantilever fixed partial dentures. J Prosthet Dent 2004;91:234-240. https://doi.org/10.1016/j.prosdent.2003.12.017
- Hansson S. The implant neck: Smooth or provided with retention elements, A biomechanical approach. Clin Oral Imolant Res 1999;5:394-405.
- Gardner DM. Platform switching as a means to achieving implant esthetics. New York State Dental Journal 2005;71:34-37.
- Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol 1997;23:104-111.
- Spivey JD, Kong W, Fotus PG, et al. Stress distribution at the bone to implant interface: A 3-D finite element analyses(abstract 106). J Dent Res 1993;72:117.
- Clelland NL, Lee JK, Bimbenet OC, Gilat A. Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant. J Prosthodont 1993;2:183-189. https://doi.org/10.1111/j.1532-849X.1993.tb00405.x
- Barbier L, Vander S, Krzesinski G, Schepers E, van der Perre G. Finite element anlysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabi 1998;25:847-858. https://doi.org/10.1046/j.1365-2842.1998.00318.x