Evaluating the Impact of Attenuation Correction Difference According to the Lipiodol in PET/CT after TACE

간동맥 화학 색전술에 사용하는 Lipiodol에 의한 감쇠 오차가 PET/CT검사에서 영상에 미치는 영향 평가

  • Cha, Eun Sun (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Hong, Gun chul (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Park, Hoon (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Choi, Choon Ki (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Seok, Jae Dong (Department of Nuclear Medicine, Samsung Medical Center)
  • 차은선 (삼성서울병원 핵의학과) ;
  • 홍건철 (삼성서울병원 핵의학과) ;
  • 박훈 (삼성서울병원 핵의학과) ;
  • 최춘기 (삼성서울병원 핵의학과) ;
  • 석재동 (삼성서울병원 핵의학과)
  • Received : 2013.01.31
  • Accepted : 2013.04.03
  • Published : 2013.04.27

Abstract

Purpose: Surge in patients with hepatocellular carcinoma, hepatic artery chemical embolization is one of the effective interventional procedures. The PET/CT examination plays an important role in determining the presence of residual cancer cells and metastasis, and prognosis after embolization. The other hand, the hepatic artery chemical embolization of embolic material used lipiodol produced artifacts in the PET/CT examination, and these artifacts results in quantitative evaluation influence. This study, the radioactivity density and the percentage error was evaluated by the extent of the impact of lipiodol in the image of PET/CT. Materials and Methods: 1994 NEMA Phantom was acquired for 2 minutes and 30 seconds per bed after the Teflon, water and lipiodol filled, and these three inserts into the enough to mix the rest behind radioactive injection with $20{\pm}10MBq$. Phantom reconfigure with the iterative reconstruction method the number of iterations for two times by law, a subset of 20 errors. We set up region of interest at each area of the Teflon, water, lipiodol, insert artifact occurs between regions, and background and it was calculated and compared by the radioactivity density(kBq/ml) and the% Difference. Results: Radioactivity density of the each region of interest area with the teflon, water, lipiodol, insert artifact occurs between regions, background activity was $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$ (P <0.05) and it was statistically significant results. Percentage error of lipiodol in each area was 118%, compared to the water compared with the background activity 52%, compared with a teflon was 180% of the difference. Conclusion: We found that the error due to under the influence of the attenuation correction when PET/CT scans after lipiodol injection performed, and the radioactivity density is higher than compared to other implants, lower than background. Applying the nonattenuation correction images, and after hepatic artery chemical embolization who underwent PET/CT imaging so that the test should be take the consideration to the extent of the impact of lipiodol be.

급증하는 간세포암 환자에게 간동맥 화학 색전술은 효과적인 중재적 시술 방법 중 하나이다. 이때 PET/CT 검사는 색전 후 잔존 암세포의 존재 및 전이여부와 예후를 판단하는데 중요한 역할을 한다. 한편 간동맥 화학 색전술에 사용되는 색전물질인 Lipiodol은 PET/CT 검사에서 인공물을 생성하고 정량평가에 영향을 준다. 이에 본 연구는 Lipiodol이 영상에 미치는 영향의 정도를 방사능 값과 백분율 오차로 평가하고자 하였다. 1994 NEMA Phantom에 Lipiodol과 Teflon, 물을 세 개의 삽입물에 넣고 나머지 부분을 배후 방사능 $20{\pm}10MBq$를 주입하고 충분히 섞은 후 2분 30초/bed data를 획득 하였다. 재구성 방법은 반복 영상 재구성법으로 반복횟수 2회, 부분 집합 수 20을 적용하였으며, Lipiodol과 Teflon, 물, 인공물 발생부위, 배후 방사능에 관심영역을 설정하고 방사능 값과 백분율 오차를 산출 하여 비교하였다. 방사능 값은 Teflon, 물, Lipiodol, 삽입물 사이 인공물 발생 부위, 배후 방사능 부위에서 각 영역 중 방사능 값은 $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$(P<0.05)으로 통계적으로 유의한 차이를 보였다. 백분율 오차가 Lipiodol에서 물에 비해 118%, 배후 방사능에 비해서 52%, Teflon에 비해 180%의 차이가 있었다. Lipiodol을 주입한 후 검사에서 감약 보정의 영향을 받아 오차로 인한 방사능 농도 값이 다른 삽입물에 비해 현저히 높고 배후 방사능보다는 작다는 것을 알 수 있었다. 따라서 Lipiodol과 같은 조영 물질을 사용한 검사에서는 인공물에 대한 영향을 고려해야 하며 임상에서는 감약 보정을 적용하지 않은 영상을 참고해서 검사가 이루어 질 수 있도록 해야 한다.