In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors

I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구

  • Im, Kwang Seok (Department of Nuclear Medicine, Choenan Soon Chun Hyang University Hospital) ;
  • Choi, Hak Gi (Department of Nuclear Medicine, Choenan Soon Chun Hyang University Hospital) ;
  • Lee, Gi Hyun (Department of Nuclear Medicine, Choenan Soon Chun Hyang University Hospital)
  • 임광석 (순천향대학교 천안병원 핵의학과) ;
  • 최학기 (순천향대학교 천안병원 핵의학과) ;
  • 이기현 (순천향대학교 천안병원 핵의학과)
  • Received : 2013.01.02
  • Accepted : 2013.03.28
  • Published : 2013.04.27

Abstract

Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

우리나라의 갑상선 암이 증가함에 따라서 갑상선 전 절제술 후 고용량 방사성동위원소 치료를 받는 환자 또한 증가하였다. 하지만 치료를 위해서 사용되는 I-131의 경우 반감기가 8.01일 이며 감마선과 베타선을 내는 특징이 있어 타인에게 줄 수 있는 외부 피폭의 영향을 막기 위해 일정기간 동안 환자가 격리병실에 입원하여 치료를 받게 된다. 이틀 내지 사흘 동안의 격리치료를 한 후 퇴원 전 환자의 몸에서 나오는 방사선량이 법적 기준(70 uSv/h)에 만족하는지 확인한 후 퇴원을 하게 된다. 그리고 다음 환자가 입원 시까지 병실 곳곳의 오염도를 확인 한 후 필요 시에는 제염작업을 수행하게 된다. 우리는 이러한 일련의 과정들 상에서 의료진들이 피폭의 영향을 받게 되는 주 요인으로는 환자의 퇴원선량 확인 및 치료병실의 오염도확인과 제염작업시의 피폭으로 예상된다. 본 연구는 환자의 여러 가지 요소들을(환자의 신기능, 연령, 성별, 초기 투여용량, Tg, Tg-ab)정하고 그 인자들을 통해 환자의 퇴원선량 및 치료병실 오염도에 어떠한 영향을 미치는지 알아보고자 한다. 본원에서 2011년 8월 1일부터 2012년 5월 29일까지 입원하여 고용량방사성 요오드 치료를 받은 환자 151명을 대상으로 실시하였다. 환자의 glomerular filtration rate (GFR) 값이 높을수록 퇴원선량이 낮은 상관관계를 보였다(P<0.001).초기 투여용량의 경우 5.5 GBq (150 mCi) 미만과 5.5 GBq (150 mCi) 이상을 투여 받은 환자군 두 그룹 사이에 평균 퇴원선량을 비교 분석한 결과 5.5 GBq (150 mCi) 미만을 투여 받은 환자 군에서 퇴원선량이 유의하게 낮음을 알 수 있었다($23.95{\pm}10.44uSv/h$, $28.65{\pm}11.79uSv/h$). 연령,성별, Tg, Tg-ab는 환자의 퇴원 선량과 유의한 관계를 보이지 않았다(p>0.05). 그리고 치료병실 오염도는 환자의 퇴원선량과 환자의 신기능과는 유의한 관계를 보이지 않았다 (p>0.05). 병실 오염도의 경우는 입원기간 동안 환자의 생활습관이나 기타 다른 다양한 요인에 의해 영향을 받을 것으로 사료된다. 비록 성별의 집단 간에 따라서 오차가 있다고 여겨지지만 추후 더 많은 환자들을 비교 분석 한다면 도움이 될 것이라고 판단된다. 또한 퇴원선량과 병실의 오염도에 영향을 줄 수 있는 기타 다른 요인들에 대해서도 지속적으로 연구한다면 환자 본인의 피폭뿐만 아니라 가족과 그주변인 의료진들에게도 조금이나마 피폭의 영향을 감소 시킬 수 있을 것이라고 사료된다.