Analyses of Energy Savings and Night Heating Performance of a Movable Thermal Insulation Shuttered Window

단열셔터를 적용한 구동창호의 에너지 절감 및 야간 난방성능 분석

  • Lee, Jang-Man (Department of Environmental Engineering of Architecture, Hanyang University) ;
  • Cho, Soo (Department of Building Energy, Korea Institute of Energy Research) ;
  • Lim, Sang-Hoon (Department of Building Energy, Korea Institute of Energy Research) ;
  • Song, Kyoo-Dong (School of Architecture and Architectural Engineering, Hanyang University)
  • 이장만 (한양대학교 건축환경공학과) ;
  • 조수 (한국에너지기술연구원) ;
  • 임상훈 (한국에너지기술연구원) ;
  • 송규동 (한양대학교 건축공학)
  • Received : 2012.11.16
  • Published : 2013.03.10

Abstract

Usually, a window tends to have a lower thermal performance, than that of an ordinary wall. This study analyzes the enhancement of thermal performance of a window, when a Thermal Insulation Shutter is installed. The analyses were conducted at the laboratory, and with a full-scale mockup house, and the U-factor and heating load were examined. The laboratory results show that the U-factor increased by approximately 28%, when a Thermal Insulation Shutter was installed. The temperature difference was about $5^{\circ}C$, and this shows that the Thermal Insulation Shutter enhances the thermal performance of the window, when installed. The mockup house was used to calculate the heating load; the heating load was reduced by more than 41%, and shows that the installation of a Thermal Insulation Shutter is an effective way to reduce heating energy consumption.

Keywords

References

  1. KS F 2278, Test Method of Thermal Resistance for Windows and Doors.
  2. Cho, S., 2012, A Study on Thermal Performance Simulation and Evaluation of the Window Combined with Thermal Insulating Shutter, Architectural Institute of Korea, Vol. 28, No. 10, pp. 327-334
  3. Kim, C. N., 2010, A Study on the Reduction Performance of Building Energy Demand by Using the Shading Device Control, Korea Institute of Ecological Architecture and Environment, Vol. 10, No. 2, pp. 303-306.
  4. Choi, G. S., 2010, Performance Evaluation of Apartment Building in Case of Applying a Blind Integrated Window System, Vol. 22, No. 7, pp. 429-435.
  5. ISO 7730, Ergonomics of the thermal environment- Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria.
  6. Yoo, M. H., 2012, Evaluation on Cooling Performance of Thermally Activated Building System by Insulation and Shading Conditions in Apartments, Journal of the Korean Housing Association, Vol. 23, No. 2, pp. 107-114. https://doi.org/10.6107/JKHA.2012.23.2.107
  7. Park, S. H., 2010, An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment, Vol. 22, No. 6, pp. 392-397.