재생형 송풍기의 공력음향학적 성능 해석 방법

Aero-acoustic Performance Analysis Method of Regenerative Blower

  • 투고 : 2012.10.22
  • 심사 : 2013.02.27
  • 발행 : 2013.04.01

초록

An aero-acoustic performance analysis method of regenerative blower is developed as one of the FANDAS codes. The aerodynamic performance of regenerative blower is predicted by using momentum exchange theory coupled with pressure loss and leakage flow models. Based on the performance prediction results, the noise level and spectrum of regenerative blower are predicted by discrete frequency and broadband noise models. The combination of the performance and the noise prediction methods gives aero-acoustic performance map and noise spectrum analysis results, which are well-agreed with the actual measurement results within a few percent relative error.

키워드

참고문헌

  1. Mura, M. and Badami, M., 2012, "Leakage effects on the performance characteristics of a regenerative blower for the hydrogen recirculation of a PEM fuel cell," Energy Conversion and Management, Vol. 55, pp. 20-25. https://doi.org/10.1016/j.enconman.2011.10.002
  2. Badami, M. and Mura, M., 2012, "Comparison between 3D and 1D simulations of a regenerative blower for fuel cell applications," Energy Conversion and Management, Vol. 55, pp. 93-100. https://doi.org/10.1016/j.enconman.2011.10.003
  3. 심창열, 강신형, 2003, "재생 펌프의 유동해석 및 누설유동에 관한 연구," 대한기계학회논문집 B, 제27권 제8호, pp. 1015-1022.
  4. 임형수, 강신형, 2005, "사이드채널형 재생펌프의 성능특성에 관한 실험적 연구," 대한기계학회논문집 B, 제29권 제3호, pp. 306-313.
  5. 최영석, 이경용, 강신형, 2003, "사이드채널형 연료펌프의 성능예측," 유체기계저널, 제6권 제2호, pp. 29-33. https://doi.org/10.5293/KFMA.2003.6.2.029
  6. Badami, M. and Mura, M., 2011, "Setup and validation of a regenerative compressor model applied to different devices," Energy Conversion and Management, Vol. 52, pp. 2157-2164. https://doi.org/10.1016/j.enconman.2010.10.044
  7. 이찬, 성형진, 권장혁, 정명균, 1991, "재생펌프의 성능해석 및 최적화에 관한 연구," 대한기계학회논문집, 제15권 제2호, pp. 661-667.
  8. Idelchik, I.E., 2001, Handbook of Hydraulic Resistance, 3rd edition, Begell House.
  9. Wright, S. E., 1976, "The acoustic spectrum of axial flow machines," Journal of Sound and Vibration, Vol.45, No.2, pp. 165-223. https://doi.org/10.1016/0022-460X(76)90596-4
  10. Mugridge, B. D., 1976, "Noise Characteristics of Axial and Centrifugal Fans as Used in Industry," Shock and Vibration Digest, Vol. 45, No. 3.

피인용 문헌

  1. vol.17, pp.2, 2014, https://doi.org/10.5293/kfma.2014.17.2.063
  2. Optimization of a regenerative blower to enhance aerodynamic and aeroacoustic performance vol.30, pp.3, 2016, https://doi.org/10.1007/s12206-016-0223-5