References
- H. C. Lowe, S. N. Oesterle, and L. M. Khachigian, "Coronary instent restenosis: current status and future strategies." JACC, 39, 183-193 (2002).
- P. C. Gordon, C. M. Gibson, D. J. Cohen et al., "Mechanisms of restenosis and redilation within coronary stents-quantitative angiographic assessment." JACC, 21, 1166-1174 (1993). https://doi.org/10.1016/0735-1097(93)90241-R
- R. S. Schwartz, D. R. Holmes, and E. J. Topol, "The restenosis paradigm revisited: an alternative proposal for cellular mechanisms." JACC, 20, 1284-1293 (1992). https://doi.org/10.1016/0735-1097(92)90389-5
- N. A. Scott, G. D. Cipolla, C. E. Ross et al., "Identification of a potential role for the adventitia in vascular lesion formation after balloon overstretch injury of porcine coronary arteries." Circ, 93, 2178-2187 (1996). https://doi.org/10.1161/01.CIR.93.12.2178
- H. K. Lee, S. H. Woo, D. S. Choi et al., "A Case of the Zone III Penetrating Neck Injury with Internal Carotid Artery Laceration Treated by an Urgent Endovascular Stent Technique." Korean J Otolaryngol-Head Neck Surg, 53, 236-240 (2010). https://doi.org/10.3342/kjorl-hns.2010.53.4.236
- K. H. Kim, M. H. Jeong, S. N. Hong et al., "The clinical effects of drug-eluting stents for the treatment of coronary in-stent restenosis." Korean Circ J, 35, 443-447 (2005).
- M. K. Hong, "Medical Treatments To Prevent In-stent Restenosis.", Korean Circ J, 29, 353-356 (1999). https://doi.org/10.4070/kcj.1999.29.4.353
- A. Kastrati, J. Mehilli, N. von Beckerath et al., "Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis." JAMA, 293, 165-171 (2005).
- K. S. Cha, M. H. Jeong, S. U. Lee et al., "The effects of local delivery of paclitaxel nanoparticle on porcine coronary stent restenosis." Korean Circ J, 30, 208-220 (2000). https://doi.org/10.4070/kcj.2000.30.2.208
- G. G. Stefanini, R. A. Byrne, P. W. Serruys et al., "Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials." Eur Heart J, 33, 1214-1222 (2012). https://doi.org/10.1093/eurheartj/ehs086
- H. Tamai, K. Igaki, E. Kyo et al., "Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans." Circ, 102, 399-404 (2000). https://doi.org/10.1161/01.CIR.102.4.399
- A. Abizaid, and J. R. Costa, "New Drug-Eluting Stents An Overview on Biodegradable and Polymer-Free Next-Generation Stent Systems." Circ, 3, 384-393 (2010).
- H. Takahashi, D. Letourneur, and D. W. Grainger, "Delivery of large biopharmaceuticals from cardiovascular stents: a review." Biomacromolecules, 8, 3281-3293 (2007). https://doi.org/10.1021/bm700540p
- H. S. Kang, J. S. Kim, B. S. Kim et al., "Drug Release Characteristics of Biodegradable Polymers for Stent Coating." Korean Journal of Biotechnology and bioengineering, 18, 109-110 (2003).
- C. J. Pan, J. Tang, Y. Weng et al., "Preparation, characterization and anticoagulation of curcumin-eluting controlled biodegradable coating stents." J Control Release, 116, 42-49 (2006). https://doi.org/10.1016/j.jconrel.2006.08.023
- H. J. Patel, S. H. Su, C. Patterson et al., "A combined strategy to reduce restenosis for vascular tissue engineering applications." Biotechnol prog, 22, 38-44 (2006). https://doi.org/10.1021/bp050135e
- C. J. Pan, J. J. Tang, Y. J. Weng et al., "Preparation and characterization of rapamycin-loaded PLGA coating stent." J Mater Sci Mater Med, 18, 2193-2198 (2007). https://doi.org/10.1007/s10856-007-3075-9
- P. Lu, H. Fan, Y. Liu et al., "Controllable biodegradability; drug release behavior and hemocompatibility of PTX-eluting magnesium stents." Colloids Surf B Biointerfaces, 83, 23-28 (2010).
- A. W. Heldman, L. Cheng, G. M. Jenkins et al., "Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis." Circ, 103, 2289-2295 (2001). https://doi.org/10.1161/01.CIR.103.18.2289
- T. H. Park, E. A. Jo, and K. Na, "Development of Polymeric Coating Material for Effective Drug-eluting Stent." Polymer (Korea), 35, 483-487 (2011).
- S. M. Moon, S. G. Yang, and K. Na, "An acetylated polysaccharide- PTFE membrane-covered stent for the delivery of gemcitabine for treatment of gastrointestinal cancer and related stenosis." Biomaterials, 32, 3603-3610 (2011). https://doi.org/10.1016/j.biomaterials.2011.01.070
- S. Jayaraman, Process for coating a surface of a stent, United states 6517889, 2003.
- T. Paragkumar N, D. Edith, and J. L. Six, "Surface characteristics of PLA and PLGA films." Applied Surface Science, 253, 2758-2764 (2006). https://doi.org/10.1016/j.apsusc.2006.05.047
- F. Burkersroda, L. Schedl, and A. Gopferich, "Why degradable polymers undergo surface erosion or bulk erosion." Biomaterials, 23, 4221-4231 (2002). https://doi.org/10.1016/S0142-9612(02)00170-9
- F. Alexis, "Factors affecting the degradation and drug-release mechanism of poly (lactic acid) and poly [(lactic acid)-co-(glycolic acid)]." Polym Int, 54, 36-46 (2004).
- Y. Arima, and H. Iwata, "Effect of wettability and surface functional groups on protein adsorption and cell adhesion using well-defined mixed self-assembled monolayers." Biomaterials, 28, 3074-3082 (2007). https://doi.org/10.1016/j.biomaterials.2007.03.013
- Y. Tamada, and Y. Ikada, "Effect of preadsorbed proteins on cell adhesion to polymer surfaces." J Colloid Interface Sci, 155, 334-339 (1993). https://doi.org/10.1006/jcis.1993.1044
- G. Bruinsma, H. Van der Mei, and H. Busscher, "Bacterial adhesion to surface hydrophilic and hydrophobic contact lenses." Biomaterials, 22, 3217-3224 (2001). https://doi.org/10.1016/S0142-9612(01)00159-4
- M. D. Pierschbacher, C. J. Honsik, and L. B. Dreisbach, Hydrophobic attachment site for adhesion peptides, United States 5120829, 1992.
- Kytai T. Nguyen, Nishat Shaikh, Liping Tan et al., "Molecular responses of vascular smooth muscle cells and phagocytes to curcumin-eluting bioresorbable stent materials." biomaterials, 25, 5333-5346 (2004). https://doi.org/10.1016/j.biomaterials.2003.12.033
- Derick C. Miller, Karen M. Haberstroh, Thomas J. Webster, "Mechanism(s) of increased vascular cell adhesion on nanostructured poly(lactic-co-glycolic acid) films." J Biomed Mater Res A, 73A, 476-484 (2005). https://doi.org/10.1002/jbm.a.30318
- J. H. Kang, J. T. Kim, J. H. Kim et al., "Surface control of drugeluting stents by ultrasonic nanocoating of multilayered biodegradable polymers." NMDC, 420-421 (2011).