DOI QR코드

DOI QR Code

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Received : 2012.02.21
  • Accepted : 2012.12.14
  • Published : 2013.05.01

Abstract

This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

Keywords

References

  1. Gyugyi L., "Reactive power generation and control by thyristor circuits", IEEE Trans. Ind. Appl., Vol. 15, No. 5, pp. 521-532, 1979.
  2. Mahanty R., "Large value AC capacitor for harmonic filtering and reactive power compensation", IET Gen. Transm. Distrib., Vol. 2, No. 6, pp. 876-891, 2008. https://doi.org/10.1049/iet-gtd:20080004
  3. Hirve S., Chatterjee K., Fernandes B. G., Imayavaramban M. and Dwari S., "PLL-less active power filter based on one-cycle control for compensating unbalanced loads in three-phase four-wire system", IEEE Trans. Power Deliv., Vol. 22, No.4, pp. 2457- 2465, 2007. https://doi.org/10.1109/TPWRD.2007.893450
  4. Casaravilla G., Salvia A., Briozzo C. and Watanabe E., "Control strategies of selective harmonic current shunt active filter", IEE Proc. Gener. Transm. Distrib., Vol. 149, No. 6, pp. 689-694, 2002. https://doi.org/10.1049/ip-gtd:20020648
  5. Yash Pal, A. Swarup and Bhim Singh., "A Novel Control Strategy of Three-phase, Four-wire UPQC for Power Quality Improvement," Journal of Electrical Engineering & Technology, KIEE, September, Vol.7 (2012) No.1, pp. 1-8, 2012. https://doi.org/10.5370/JEET.2012.7.1.1
  6. Hideaki F, Hirofumi A. "The integration of series and shunt active filters", IEEE Transactions on Power Electronics; 13(2), pp. 315-322, 1998. https://doi.org/10.1109/63.662847
  7. Aredes M, Heumann K, Watanabe EH., "An universal active power line conditioner", IEEE Transactions on Power Delivery, 13(2), pp. 545-551, 1998. https://doi.org/10.1109/61.660927
  8. L. Moran, I. Pastorini, J. Dixon and R. Wallace, "Series active power filter compensates current harmonics and voltage unbalance simultaneously", Proc.IEE Gener., Trans. and Distrib., Vol. 147, No.1, pp. 31-36, 2000. https://doi.org/10.1049/ip-gtd:20000027
  9. H. Fujita and H. Akagi, "The unified power quality conditioner: The integration of series active filters and shunt active filters", IEEE, Trans. Power Electronics, Vol. 13, pp. 315-322, 1998. https://doi.org/10.1109/63.662847
  10. A. Nabae, I. Takahashi and H. Akagi, "A new neutralpoint clamped PWM inverter", IEEE, Trans. Ind. Application., Vol. IA-17, No. 5, pp. 518-523, Sept./ Oct. 1981. https://doi.org/10.1109/TIA.1981.4503992
  11. S.Diego E. Soto and Tim C. Green, "Voltage balance and control in a multi-level Unified Power Flow Controller", IEEE, Trans. On Power Delivery, Vol. 16, No. 4, pp. 732-738, Oct. 2001. https://doi.org/10.1109/61.956763
  12. A. Munduate, E. Figureres, G. Garcera, "Robust modelfollowing control of a three-level neutral point clamped shunt active filter in the medium voltage range," Elsevier, Electrical Power and Energy Systems 31, pp. 577-588, 1998.
  13. Yun Wan, Jianguo Jiang, "The study of FPGA-based three-level SVM NPC inverter," IEEE, pp. 1470- 1474, 2009.
  14. Aredes, M., Hafner, J. and Heumann, K, "Threephase four-wire shunt active filter control strategies," IEEE Transactions on Power Electronics, 12(2), pp. 311-318, 1997. https://doi.org/10.1109/63.558748
  15. Bor-Ren Lin, Chun-Hao Huang, Tsung-Yu Yang and Yung-Chuan Lee, "Analysis and Implementation of Shunt Active Power Filter with Three-Level PWM Scheme", IEEE, pp. 1580-1885, 2003.
  16. V. Khadkikar, A. Chandra, A. O. Barry and T. D. Nguyen, "Application of UPQC to protect a sensitive load at polluted distribution network", IEEE, 2006.
  17. J.Mazumdar, R. G Harley, G. K. Venayagamoorty, "Synchronous reference frame based active filter current reference generation using neural networks", IEEE, pp. 4404-4409, 2008.
  18. Hamadi, S.Rahmani, K. Al-Haddad, "A novel hybrid series active filter for power quality compensation", IEEE, pp. 1099-1104, 2007.
  19. Hai Lan, Jincheng Liang, Weiping Wu, "Reseearch of harmonic detection and fuzzy PID control in series active power filter", IEEE, pp. 2957-2962, 2007.
  20. Chennai Salim, Benchouia M-T, Golea Amar, "Harmonic currents compensation based on three-level shunt active filter using fuzzy logic current controller," Journal of Electrical Engineering & Technology, KIEE, September, Vol. 6(2011), No. 3, pp. 595-604, 2011. https://doi.org/10.5370/JEET.2011.6.5.595
  21. S.Saad L.Zellouma, "Fuzzy logic controller for threelevel shunt active filter compensating harmonics and reactive power", Elsevier, Electrical Power Systems Research 79, pp. 1337-1341, 2009. https://doi.org/10.1016/j.epsr.2009.04.003
  22. Chennai Salim, Benchouia M-T, Golea A, "Series Active Power Filter for harmonic voltage compensation using two control strategies based on fuzzy control techniques,"4th International Conference on Electrical Engineering, ICEE'2012, 2012.