DOI QR코드

DOI QR Code

신축공동주택의 상하층간 소음 및 진동전달 특성과 층간소음 차단성능에 관한 연구

Study on the Characteristic of Floor Sound and Vibration Transfer and the Blocking Function of Floor Sound for Newly Built Apartment House

  • 투고 : 2013.02.20
  • 심사 : 2013.04.24
  • 발행 : 2013.04.25

초록

This study involves 2 newly built apartment houses which are A with 23 floors as 150 mm slab width and B with 16 floors as 180 mm slab width. The impact was added by tapping and bang machine at the middle floor level of these 2 apartments and the test was arranged in terms of the characteristic of vibration and sound level which transferred to upper or down floors. As a result, impact floor shows the highest value in terms of both sound and vibration level and followed was at down floor of the Impact floor. Also, blocking function for the lightweight and heavyweight floor impact sound level was tested for each room of the apartment A and B including living room, main room, room 1 and 2. As a result, sound blocking function of B apartment was better than that of A and the function was getting worse when the room size is getting smaller.

키워드

참고문헌

  1. Choi, H. (2010). A Study on the Property of Dynamic Stiffness of Resilient Materials by Measurement Condition. Seoul National University Of Science And Technology, Unpublished master's thesis, Seoul.
  2. DIN (1986). Structural Vibration in Buildings Effect on Structures 4150 Part 2. Berlin.
  3. Fukushima, H., & Hattori, A. (2000). Introduction to sound insulation regulations in the japanese new law concerning the labeling system and the system for quality securing about new-built house. Proceeding of journal of the Acoustical Society of Japan. 753-754.
  4. Tachibana, H., & Yano, H. (1990). Subjective assessment of indoor noises-basic experiments with artificial sound. Applied Acoustics, 31, 173-184. https://doi.org/10.1016/0003-682X(90)90059-4
  5. Heo, J. (2012). Evaluation of the Characteristics of Heavyweight Impact Sound and Vibration using a Scale Model of floating floor Structures. Master's thesis, Hanyang University, Seoul.
  6. ISO 354 (2003). Acoustics-Measurement of Sound Absorption in a Reverberation Room.
  7. Sin, J. (2008). Development of Polymer-Based Composites for Reducing Heavyweight Floor Impact Noise in Apartment Buildings. Master's thesis, Chungbuk University, Cheongju.
  8. Sin, K. (2008). A Fundamental Study on Manufacturing Monolithic On-dol Floor with Floor Space Soundproofing Materials. Master's thesis, Tongmyong University, Busan.
  9. Song, G., & Kim, S. (2010). A study on the measurement and assessment of floor impact sound in the balcony remodeled apartment. Journal of the Architectural Institute of Korea, 6, 317-320.