DOI QR코드

DOI QR Code

Performance Analysis of Two-stage Compression and Two-stage Expansion Refrigeration System using Freon Refrigerants

친환경 프레온 냉매를 이용하는 단압축 단팽창 냉동시스템의 성능예측

  • Received : 2012.11.22
  • Accepted : 2013.02.03
  • Published : 2013.04.30

Abstract

In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative freon refrigerant for freon refrigerant R22 were used as working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ratio of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants have an effect on COP of this system.

Keywords

References

  1. Chaichana, C.. Aye, L. & Charters, W. W. S.(2003). Natural working fluids for solar-boosted heat pumps. Int. J. Refrigeration Vol. 26, 637-643. https://doi.org/10.1016/S0140-7007(03)00046-X
  2. fChart Software Inc(2006). Engineering Equation Solver
  3. LIM, Tae-Woo. YOU, Sam-Sang & KIM, Hwan-sung(2008), Nucleate Boiling Heat Transfer from Micor Finned Surfaces with subcooled FC-72, Jour. fish. Mar. Sci. Edu, Vol. 20, No. 3, 410-415.
  4. Roh, Geon-sang(2010). Prediction on performance of Cascade Refrigeration System using Natural Refrigerants, Jour.of Korean Soc. of Mechanical Technology, Vol. 12, No. 3, 45-51. https://doi.org/10.5762/KAIS.2012.13.4.1427
  5. Roh, Geo-nsang(2011). Prediction on performance of Cascade Refrigeration System using alternative freon Refrigerants, Jour.of Korean Soc. of Mechanical Technology, Vol. 13, No. 1, 73-79
  6. UNEP(1992). Copenhagen, Decision, The Fourth Meeting of the Parties to the Montreal Protocol
  7. YOU, Sam-Sang.LIM, Tae-Woo.JEONG, Seok-Kwon & PARK, Jong-Un(2007), A Study on gem microcooling Fing Fabrication Process for Enhancing Boiling Heat Transfer, Jour. fish. Mar. Sci. Edu, Vol. 19, No. 3, 366-372

Cited by

  1. Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants vol.19, pp.6, 2015, https://doi.org/10.9726/kspse.2015.19.6.082