DOI QR코드

DOI QR Code

A DVR Control for Compensating Unbalanced Voltage Dips of a DFIG System using Zero Sequence Components

  • Thinh, Quach Ngoc (Department of Electrical Engineering, Jeju National University) ;
  • Ko, Ji-Han (Department of the Multidisciplinary Graduate School Program for Wind Energy, Jeju National University) ;
  • Kim, Dong-Wan (Department of the Multidisciplinary Graduate School Program for Wind Energy, Jeju National University) ;
  • Kim, Eel-Hwan (Department of Electrical Engineering, Jeju National University)
  • Received : 2012.11.07
  • Accepted : 2013.01.07
  • Published : 2013.02.28

Abstract

The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results in high insulation costs and asymmetry in terminal voltages. This paper proposes the use of a proportional-resonant controller in stationary reference frames for controlling zero sequence components in the DVR to protect the DFIG during unbalanced voltage dips. To enhance the proposed control method, a comparison is carried out between two cases: with and without using the control of a zero sequence component. Simulation results are presented to verify the effectiveness of the proposed control method by using the Psim simulation program.

Keywords

References

  1. J. Lopez, E. Gubia, P. Sanchis, X. Roboam, and L. Marroyo, "Wind Turbines Based on Doubly Fed Induction Generator Under Asymmetrical Voltage Dips," IEEE Trans. Energy Convers., Vol. 23, No. 1, pp. 321-330, Mar. 2008. https://doi.org/10.1109/TEC.2007.914317
  2. M. Tsili and S. Papathanassiou, "A review of grid code technical requirements for wind farms," IET. Renewable Power Generat., Vol. 3, No. 3, pp. 308-332, Sep. 2009. https://doi.org/10.1049/iet-rpg.2008.0070
  3. L. Xu and Y. Wang, "Dynamic Modeling and Control of DFIG-Based Wind Turbine under Unbalanced Network Conditions," IEEE Trans. Power Syst., Vol. 22, No. 1, pp. 314-323, Feb. 2007. https://doi.org/10.1109/TPWRS.2006.889113
  4. L. Xu, "Coordinated control of DFIG's rotor and grid side converters during network unbalance," IEEE Trans. Power Electron., Vol. 23, No. 3, pp. 1041-1049, May 2008. https://doi.org/10.1109/TPEL.2008.921157
  5. J. Morren and S.W.H. de Haan, "Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip," IEEE Trans. Energy Convers., Vol. 20, No. 2, pp. 435-441, Jun. 2005. https://doi.org/10.1109/TEC.2005.845526
  6. D. Ramirez, S. Martinez, C.A. Platero, F. Blazquez, and R.M. de Castro, "Low-Voltage Ride-Through Capability for Wind Generators Based on Dynamic Voltage Restorers," IEEE Trans. Energy Convers., Vol. 26, No. 1, pp. 195-203, Mar. 2011. https://doi.org/10.1109/TEC.2010.2055869
  7. H. Awad, J. Svensson, and M. Bollen, "Mitigation of Unbalanced Voltage Dips Using Static Series Compensator," IEEE Trans. Power Electron., Vol. 19, No. 3, pp. 837-846, May 2004. https://doi.org/10.1109/TPEL.2004.826536
  8. C. Wessels and F. Fuchs, "High Voltage Ride Through with Facts for DFIG Based Wind Turbines," in Proc. 13th Eur. Conf. Power Electron. Appl. (EPE), pp. 1-10, Sep. 2009.
  9. D. M. Vilathgamuwa and H. M. Wijekoon, "Mitigating Zero Sequence Effects in Dynamic Voltage Restorers", IEEE Specialists Conf. Power Electron. (PESC 2007), pp. 3079-3085, June 2007.
  10. Zhongdong Yin and Lixia Zhou, "Self Zero Sequence Component Control of Dynamic Voltage Restorer in Systems with Different Neutral Point Grounded Modes," in The 7th International Conf. Power Engineering (IPEC 2005), pp. 1-4, Nov. 29 2005-Dec. 2 2005.
  11. R Pena, J.C Clare, and G.M. Asher, "Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation," IEE Proc, Vol. 143, No. 3, pp. 231-241, May 1996. https://doi.org/10.1049/ip-com:19960613
  12. R. Teodorescu, F. Blaabjerg, M. Liserre, and P. C. Loh, "Proportional-resonant controllers and filters for grid-connected voltage-source converters," IEE Proc. Electr. Power Appl., Vol. 153, No. 5, pp. 750-762, Sep. 2006.