The Microleakage in Class V Cavity Based on Different Kinds of Several Dentin Adhesive and Composite Resin

5급 와동에서 수종의 상아질 접착제와 복합레진의 종류에 따른 미세누출

  • Choi, Yoo-Seok (Department of Dental Hygiene, Graduate School of Public Health Science, Eulji University) ;
  • Jeong, Soon-Jeong (Department of Oral Histology and Developmental Biology, School of Dentistry, Chosun University) ;
  • Jeong, Moon-Jin (Department of Oral Histology and Developmental Biology, School of Dentistry, Chosun University) ;
  • Ahn, Yong-Soon (Department of Dental Hygiene, Graduate School of Public Health Science, Eulji University) ;
  • Park, Seon-Nyeo (Department of Dental Hygiene, Graduate School of Public Health Science, Eulji University) ;
  • Lim, Do-Seon (Department of Dental Hygiene, Graduate School of Public Health Science, Eulji University)
  • 최유석 (을지대학교 보건대학원 치위생학과) ;
  • 정순정 (조선대학교 치과대학 구강조직발생학교실) ;
  • 정문진 (조선대학교 치과대학 구강조직발생학교실) ;
  • 안용순 (을지대학교 보건대학원 치위생학과) ;
  • 박선녀 (을지대학교 보건대학원 치위생학과) ;
  • 임도선 (을지대학교 보건대학원 치위생학과)
  • Published : 2013.09.30

Abstract

In order to explore microleakage in class V cavity based on different kinds of several dentin adhesive and composite resin, 2 kinds of composite resin was restored and exposed after applying 4 kinds of dentin adhesives. Deposited in methylene blue solution for 4 hours and cut in parallel with tooth longitudinal axis. By observing dye penetration level of enamel and dentin margins of each restored resin following conclusion was obtained. 1. In composite resin Filtek Z350XT Universal (3M/ESPE Dental Products, USA) in enamel margin, Easy Bond (3M/ESPE Dental Products) showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2 (3M/ESPE Dental Products), Scotchbond Multi-Purpose (3M/ESPE Dental Products) and Cearfil SE Bond (Kuraray Medical Inc., Japan). In case of Filtek Z350XT Flowable (3M/ESPE Dental Products), Scotchbond Multi-Purpose showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2, Clearfil SE Bond and Easy Bond. 2. In case of Filtek Z350XT Universal in dentin margin, Easy Bond showed the lowest microleakage and this leakage was represented to be high in the order of Scotchbond Multi-Purpose, Single Bond 2 and Clearfil SE Bond. In case of Filtek Z350XT Flowable, Scotchbond Multi-Purpose and Single Bond showed the lowest microleakage and this leakage was represented to be high in the order of Clearfil SE Bond and Easy Bond. 3. In all the groups excepting S-U group (Single Bond 2+Filtek Z350XT Universal), enamel margin showed more higher microleakage than that of dentin margin. 4. There was a difference between enamel and dentin margin among each group but it was not significant statistically (p>0.05). When summarizing this result, it is considered that composite resin and dentin adhesive could be applied selectively and particularly in case of applying 1-step self-etching dentin adhesive, this method would be advantageous for manipulation convenience and shortening of operation time.

5급 와동에서 상아질 접착제와 레진의 종류에 따른 미세누출을 알아보고자 64개의 건전한 상 하악 소구치 및 대구치에 5급 와동을 형성하였다. 형성된 와동에 4종의 상아질 접착제를 각각 적용하고 2종류의 복합레진을 수복하여 법랑질과 상아질 변연부 색소침투 정도를 실체현미경하에서 23배율로 관찰하여 미세누출 점수를 기록한 후 각 군 간의 유의성을 검정하였다. 연구 결과, 5급 와동 수복 시 상아질 접착제와 레진의 종류에 따른 미세누출은 통계적으로 유의하지 않았다. 그러나 복합레진 Filtek Z350XT Universal 적용 시 1단계 자가부식 접착제 Adaper Easy Bond에서 미세누출이 낮게 나타났고, 유동성레진 Filtek Z350XT Flowable 적용 시 3단계 전부식 접착제 Adaper Scotchbond Multi-Purpose, 2단계 전부식 접착제 Adaper Single Bond 2에서 미세누출이 낮게 나타났다. 따라서 복합레진 및 상아질 접착제의 선택적 적용이 가능하며 특히, 1단계 자가부식 상아질 접착제 적용 시 조작의 편이성과 시술시간의 단축에 유리할 것으로 생각된다.

Keywords

References

  1. Koo BW, Son HH: The effect of dentin bonding agents on marginal leakage following restoration on the cervical abrasion. J Korean Acad Con Dent 12: 55-63, 1987.
  2. Brackett WW, Gunnin TD, Gilpatrick RO, Browning WD: Microleakage of class V compomer and light cured glass ionomer restorations. J Prosthetic Dent 79: 261-263, 1998. https://doi.org/10.1016/S0022-3913(98)70234-3
  3. Cooley RL, Robbins JW: Glass ionomer microleakage in class V restorations. Gen Dent 36: 113-115, 1988.
  4. McCoy RB, Andersen MH, Lepe X: Clinical success of class V composite resin restorations without mechanical retention. J Am Dent Assoc 129: 593-599, 1998. https://doi.org/10.14219/jada.archive.1998.0277
  5. Lee SY: An in vivo study of microleakage of composite resins. Unpublished master's thesis, Chonbuk National University, Jeonju, 2003.
  6. Bae SB, Cho YG, Lee MS: Comparison of marginal microleakage between low and high flowable resins in class V cavity. J Korean Acad Con Dent 34: 477-483, 2009. https://doi.org/10.5395/JKACD.2009.34.6.477
  7. Ferdianakis K: Microleakage reduction from newer esthetic restorative materials in permanent molars. J Clin Pediatr Dent 22: 221-229, 1998.
  8. Celik C, Ozgunaltay G, Attar N: Clinical evaluation of flowable resins in non-carious cervical lesions two year results. Oper Dent 32: 313-321, 2007. https://doi.org/10.2341/06-93
  9. Kim HJ: Microleakage of flowable resin composite by types of adhesive systems. Unpublished master's thesis, Chosun University, Gwangju, 2007.
  10. Lee KW, Choung SJ, Han YC, et al.: Prospective clinical evaluation of three different bonding systems in class V resin restorations with or without mechanical retention. J Korean Acad Con Dent 31: 300-311, 2006. https://doi.org/10.5395/JKACD.2006.31.4.300
  11. Summitt JB, Robbins JW, Schwartz RS: Fundamentals of operative dentistry. In: A contemporary approach. 2nd ed. Quintessence Pub., Chicago, p.396, 2001.
  12. Inoue S, Vargas MA, Abe Y, et al.: Microtensile bond strength of eleven contemporary adhesives to dentin. J Adhes Dent 3: 237-245, 2001.
  13. Inoue S, Vargas MA, Abe Y, et al.: Microtensile bond strength of eleven contemporary adhesives to enamel. J Am Dent Assoc 16: 329-334, 2003.
  14. Piva E, Meinhardt L, Demarco FF, Powers JM: Dye for caries detection influence on composite and compomer microleakage. Clin Oral Invest 6: 244-248, 2002. https://doi.org/10.1007/s00784-002-0182-3
  15. Lim YH: The comparison of microleakage of class V composite resin restorations. Unpublished master's thesis, Pusan National University, Busan, 2001.
  16. Smith DC, Williams DP: Biocompatibility of dental material. In: Glenn JF. Composition and properties of unfilled and composite resin restorative materials. vol. III, CRC Press, Boca Rapton, pp.97-130, 1982.
  17. Yazici AR, Baseren M, Dayangc B: The effect of flowable resin composite on microleakage in class V cavities. Oper Dent 28: 42-46, 2003.
  18. Kang SH: Microleakage of microfill and flowable composite resins in class V cavity after load cycling. Unpublished master's thesis, Seoul National University, Seoul, 2003.
  19. Turssi CP, Ferracane JL, Ferracane LL: Wear and fatigue behavior of nano-structured dentin resin composite. J Biomed Mater Res Part B 78: 196-203, 2006.
  20. Park JE: The study on the microleakage pattern of flowable composite resin restorations according to the type of adhesive materials. Unpublished master's thesis, Dankook University, Cheonan, 2007.
  21. Nam KY, Kim JB, Jang BC, Kwon TY, Kim KH: Effects of dentin bonding agents on bonding durability of a flowable composite to dentin. J Dent Master 26: 224-231, 2007. https://doi.org/10.4012/dmj.26.224
  22. Attar N, Korkmaz Y: Effect of two light-emitting diode (LED) and one halogen curing light on the microleakage of class V flowable composite restorations. J Contemp Dent Prac 8: 80-88, 2007.
  23. Saunders WP, Saunders EM: Microleakage of bonding agents with wet and dry bonding techniques. J Am Dent 9: 34-36, 1996.
  24. Van Meerbeek B, De Munck J, Yoshida Y, Inoue S, Vargas M: Buonocore memorial lecture Adhesion to enamel and dentin current status and future challenges. Oper Dent 28: 215-235, 2003.
  25. Jeong JH: Marginal microleakage of single step adhesives. Unpublished master's thesis, Chosun University, Gwangju, 2004.