AC PDP에서 CLHS 구동 방법에 의한 ITO Gap에 따른 방전 특성

The Characteristics of the Discharge According to ITO Gap by the CLHS Driving Method in AC PDP

  • 신재화 (인천대 전기공학과) ;
  • 최명규 (가천대학교 전기공학과) ;
  • 김근수 (영진전문대학 전자정보통신계열)
  • Shin, Jae-Hwa (Dep. of Electrical Engineering, University of Incheon) ;
  • Choi, Myung-Gyu (Dep. of Electrical Engineering, Gachon University) ;
  • Kim, Gun-Su (School of Electronics & Info-Communication, Yeungjin College)
  • 투고 : 2012.10.19
  • 심사 : 2012.12.13
  • 발행 : 2013.01.01

초록

In order to reduce the power consumption in international standard IEC62087, the luminance efficiency should be improved at the low discharge load rather than at the high discharge load. Thus, this paper analysed the characteristics of the discharge at the panels with ITO Gap of $65{\mu}m$, $80{\mu}m$, and $100{\mu}m$ in 50-inch PDP with FHD resolution. It was well known that the long gap panel improves the luminance and the luminous efficiency. However, it is very difficult to drive the panel due to high driving voltage. When the normal driving method was applied at the panel with ITO gap of $100{\mu}m$, the phenomenon of the double peak was generated in the sustain period. We confirmed that main factor of the double peak is the self-erasing discharge. When the CLHS driving method was applied at the panel with ITO gap of $100{\mu}m$, the self-erasing discharge was improved in the sustain period. Also, the $V_S$ and $V_A$ minimum voltage of the CLHS driving method decreased about 9V and 12V compared with those of the normal driving method. Moreover, when the CLHS driving method was applied to the panel with ITO gap of $100{\mu}m$, the luminance and the luminous efficiency increased compared with those of the normal driving method. The luminance and the luminous efficiency greatly increased at the low discharge load. The less discharge load, the higher increase rate of the luminance and the luminous efficiency. Especially, the luminous efficiency at ITO gap of $100{\mu}m$ increased about 26.3% at the discharge load of 4% compared with that at ITO gap of $65{\mu}m$.

키워드

참고문헌

  1. Gun-Su Kim and Seok-Hyun Lee, "Temperature Dependence of Address Discharge at High Temperature in an AC-PDP", IEEE Transactions on Plasma Science, Vol. 38. No. 11, pp 3136-3142, November, 2010. https://doi.org/10.1109/TPS.2010.2076367
  2. Gun-Su Kim and Seok-Hyun Lee, "Analysis of Misdischarge as Aging Characteristics in an AC-PDP", IEEE Transactions on Plasma Science, Vol. 39. No. 6, pp 1-5, Jun, 2011. https://doi.org/10.1109/TPS.2011.2171230
  3. Jae-Hwa Shin and Gun-Su Kim, "CLHS Driving Method for Reducing Reactive Power Consumption in AC PDP", Trans. KIEE, Vol. 60, No. 3, pp 577-581, Mar, 2011. https://doi.org/10.5370/KIEE.2011.60.3.577
  4. Jae Young Kim, Hyun Kim, Heung-Sik Tae, Jeong Hyun Seo and Seok-Hyun Lee, "Effect of Voltage Distribution Among Three Electrodes on Microdischarge Characteristics in AC-PDP With Long Discharge Path", IEEE Transactions on Plasma Science, Vol. 34. No. 6, pp 2579-2587, December, 2006. https://doi.org/10.1109/TPS.2006.887766
  5. Tae Jun Kim, Joong Kyun Kim, and Ki-Woong Whang, "High Luminous Efficacy Characteristics of Long Gap Structure AC Plasma Display Panel With Self-Ignition Electrode", IEEE Transactions on Plasma Science, Vol. 35, No. 6, pp 1775-1780, December, 2007. https://doi.org/10.1109/TPS.2007.907906
  6. Kyung Cheol Choi, Cheol Jang, and Jin Bhum Yun, "Driving Characteristics of a High-Efficacy AC PDP With an Auxiliary Electrode", IEEE Transactions on Electron Device, Vol. 55, No. 6, pp 1338-1344, June, 2008. https://doi.org/10.1109/TED.2008.921003