DOI QR코드

DOI QR Code

DC Offset Current Compensation Method of Transformeless Fuel Cell/PV PCS

무변압기형 연료전지/태양광용 PCS의 직류분 보상기법

  • Received : 2013.11.04
  • Accepted : 2013.12.22
  • Published : 2013.12.30

Abstract

This paper proposes DC offset current compensation method of transformerless fuel cell/PV PCS. DC offset current is generated by the unbalanced internal resistance of the switching devices in full bridge topology. The other cause is the sensitivity of the current sensor, which is lower than DSP in resolution. If power converter system has these causes, the AC output current in the inverter will generate the DC offset. In case of transformerless grid-connected inverter system, DC offset current is fatal to grid-side, which results in saturating grid side transformer. Several simulation results show the difficulties of detecting DC offset current. Detecting DC offset current method consists of the differential amplifiers and PWM is compensated by the output of the Op amp circuit with integrator controller. PSIM simulation verifies that the proposed method is simpler and more effective than using low resolution current sensor alone.

Keywords

References

  1. Ahfock and Bowtell, leslie, "DC Offset Elimination in a Single Phase Grid-Connected", AUPEC 2006
  2. Hong, Ki-Nam, "Output Current DC Offset Removal Method for Trans-less PV inverter, Journal of the KSES, March. 2012 https://doi.org/10.7836/kses.2012.32.spc3.255