DOI QR코드

DOI QR Code

편심재하된 하이브리드 FRP-콘크리트 합성 기둥의 구조적 특성

The Structrual Behavior of Eccentrically Loaded Hybrid FRP-Concrete Composite Columns

  • 투고 : 2013.11.04
  • 심사 : 2013.12.11
  • 발행 : 2013.12.31

초록

Pile foundations constructed by the fiber reinforced polymer plastic piles have been used in coastal and oceanic regions in many countries. Generally, fiber reinforced polymer plastic piles are consisted of filament winding FRP which is used to wrap the outside of concrete pile to increase the axial load carrying capacity or pultruded FRP which is located in the core concrete to resist the bending moment arising due to eccentric loading. In this paper, the analytical procedures of hybrid concrete filled FRP tube flexural members are suggested based on the CFT design method. Moreover, the analytical results are compared with the experimental results to obtained by the previous researches. The results of comparison analyses are performed to estimate the accuracy of the analytical procedure for hybrid FRP-concrete composite compression test, members under eccentrical loading.

키워드

참고문헌

  1. American Concrete Institute (2008a), Building Code Requirements for Structural Concrete and Commentary (ACI 318-08), ACI Committee 318, Farmington Hills, Michigan.
  2. American Concrete Institute (2008b), Fiber-Reinforced Polymer Reinforcement for Concrete Structures (ACI 440R), ACI Committee 440, Farmington Hills, Michigan.
  3. American Institute of Steel Construction (2005), Specification for Structural Steel Building, AISC, Inc., Chicago, Illinois.
  4. An, D. J. (2011), Structural Characteristics of Hybrid FRP-Concrete Composite Piles, Ph. D. Thesis, Department of Civil Engineering, Hongik University, Seoul, Korea. (in Korean).
  5. Beheshti-Aval, S. B. (2012), "Strength Evaluation of Concrete Filled Steel Tubes Subjected to Axial-Flexural Loading by ACI and AISC-LRFD codes along with Three Dimensional Nonlinear Analysis," International Journal of Civil Engineering, Vol. 10, No. 4, pp. 280-290.
  6. Choi, J. W., Joo, H. J., Kang, I. K., and Yoon, S. J. (2012), "Design of Hybrid FRP-Concrete Composite Circular Members under Compression and Flexure," The 2nd International Conference on Advanced Polymer Matrix Composites, Harbin, China, pp. 22-25.
  7. Choi, J. W., Joo, H. J., Nam, J. H., and Yoon, S. J. (2010), "Development of Hybrid CFFT Pile," Journal of the Korean Society for Advanced Composite Structures, Vol. 1, No. 2, pp. 20-28. (in Korean).
  8. Choi, J. W., Lee, Y. G., Joo, H. J., Kang, I. K., and Yoon, S. J. (2011a), "Load Carrying Capacity of Hybrid FRP-Conrete Composite Compression Members," The 2011 World Congress on Advances in Structural Engineering and Mechanics, Vol. 18-22, pp. 4197-4205.
  9. Choi, J. W., Park, J. S., Nam, J. H., An, D. J., and Yoon, S. J. (2011b), "An Experimental Study for the Compression Strength of Hybrid CFFT Pile," Journal of the Korean Society for Advanced Composite Structures, Vol. 2, No. 1, pp. 30-39. (in Korean).
  10. Fam, A. Z. and Rizkalla, S. H. (2002), "Flexural Behavior of Concrete Filled Fiber-Reinforced polymer Circular Tube," Journal of Composites for Construction, Vol. 6, No. 2, pp. 123-132. https://doi.org/10.1061/(ASCE)1090-0268(2002)6:2(123)
  11. Kang, I. K. (2012), A Study on the Development of FRP-Concrete Composite Pile, Technical Research Report. (in Korean).
  12. Kim, H. S. (2010). Analysis on the Flexural Behavior of Composite Bridge with CFT Girder, MS Thesis, Korea University, Seoul, Korea. (in Korean).
  13. Lee, Y. G., Choi, J. W., Park, J. S., and Yoon, S. J. (2011), "Compression Strength Test of FRP Reinforced Concrete Composite Pile," Journal of the Korean Society for Advanced Composite Structures, Vol. 2, No. 4, pp. 19-27. (in Korean). https://doi.org/10.11004/kosacs.2011.2.4.019
  14. Shin, K. Y. (2011), Estimation of Load Carrying Capacity of Hybrid FRP-Concrete Composite Pile, Ph. D. Thesis, Department of Civil Engineering, Hongik University, Seoul, Korea. (in Korean).